Introduction

– Be advised that different operating volt-

ages require the use of different types
of line cord and attachment plugs.

– Always observe the local safety regula-

tions. Ensure that the factory-set power
requirements for the device (refer to the
label  on the back of the monitor) cor-
responds to the mains supply in your
region.

– This equipment should be installed

near  the socket outlet and disconnec-
tion of the device should be easily ac-
cessible.

– To completely disconnect from AC

mains, disconnect the power supply
cord from the AC receptacle.

– The mains plug of the power supply

shall remain readily operable.

– Do not install in a confined space.
– Do not open the unit – risk of electric

shock inside.

Caution:

You are cautioned that any change or mod-
ifications  not  expressly  approved  in  this 
manual could void your authority to operate 
this equipment.

Service

– There are no user-serviceable parts in-

side.

– All service must be performed by quali-

fied personnel.

EMC/EMI

This equipment has been tested and found 
to comply with the limits for a Class B Dig-
ital device, pursuant to part 15 of the FCC 
rules.
These limits are designed to provide rea-
sonable protection against harmful inter-
ference in residential installations. This 
equipment generates, uses and can radi-
ate radio frequency energy and, if not in-
stalled and used in accordance with the in-
structions, may cause harmful interference 
to radio communications. However, there is 
no guarantee that interference will not oc-
cur in a particular installation. If the equip-
ment does cause harmful interference to 
radio or television reception, which can be 
determined by turning the equipment off an 
on, the user is encouraged to try to correct 
the interference by one or more of the fol-
lowing measures.

– Reorient or relocate the receiving an-

tenna.

– Increase the separation between the

equipment and receiver.

– Connect the equipment into an outlet

on a circuit different from that to which 
the receiver is connected.

– Consult the dealer or an experienced

radio/TV technician for help.

For customers in Canada:

This Class B digital apparatus complies 
with Canadian ICES-003.
Cet appareil numérique de la classe B est 
conforme à la norme NMB-003 du Canada.

Dynaudio Professional BM Compact mkIII manual.indd   2

2014-03-11   11:40

Содержание Excite X14A

Страница 1: ...Owners Manual Excite X14A ...

Страница 2: ......

Страница 3: ...has two blades and a third grounding prong The wide blade or the third prong are provided for your safe ty If the provided plug does not fit into your outlet consult an electrician for re placement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the ap paratus 11 Only use attachments a...

Страница 4: ...d and found to comply with the limits for a Class B Dig ital device pursuant to part 15 of the FCC rules These limits are designed to provide rea sonable protection against harmful inter ference in residential installations This equipment generates uses and can radi ate radio frequency energy and if not in stalled and used in accordance with the in structions may cause harmful interference to radi...

Страница 5: ...Introduction Owner s manual 3 ...

Страница 6: ...rs of use you may notice advance in sound quality and further subtle improvements in subsequent hours of use a ant Introduction Congratulations on your purchase of the Dynaudio Excite X14A With the right care and attention it will provide many years of excellent and trouble free audio reproduc tion It is most important however that you take a few minutes at this early stage of your speaker s life ...

Страница 7: ...from your monitors Please follow the instructions on the following pages 3 8 5 7 1 2 6 4 1 Power On Off switch 2 AC power Input 3 Balanced analog input XLR 4 Unbalance analog input RCA 5 Power Mode switch 6 Remote 7 Filter switches High Pass LF Low filter setting MF Mid filter setting HF Hi filter setting 8 Level Sensitivity switch ...

Страница 8: ...econds 7 Filter switches LF This switch controls the bass gain level using shelf type EQ The level can be set to 2 dB 0 dB or 2 dB This filter is used to adjust for the prox imity of boundaries so if positioned close to wall or corner use the 2 dB setting If positioned far from walls use the 2 dB or 0 position depending on other equipment and personal taste MF This switch sets a notch filter used ...

Страница 9: ...l built in protection systems to reduce the risk of hazard or damage due to overloading Both power amplifiers have thermal protection This activates if a problem should occur and helps protect both the electronics and the loudspeaker drivers The woofer channel has a built in limiter that protects the woofer unit from too much excursion It works by reducing the gain of the circuit when a certain th...

Страница 10: ... driv ers When a noticeable distortion occurs please turn down the level to your speak ers Avoid hot plugging the equipment con nected to the monitors Always turn off the speaker and other equipment when plug ging or unplugging signals or switching equipment on or off Do not touch the drive units by hand The tweeter especially uses a very fine fabric dome with an ultra thin coating Options Compani...

Страница 11: ...m Crossover 2 way Crossover Frequencies 3000 Hz Crossover Slope 12 dB oct Connection XLR balanced and RCA unbalanced Recommended Placing Stand Tweeter 27 mm soft dome rear chamber magnetic fluid 4 mm aluminum front Pure aluminum wire voice coil Woofer 145 mm molded aluminum frame One piece thermo formed MSP cone 38 mm voice coil with pure aluminum wire on aluminum former Cabinet Designed to be pla...

Страница 12: ... Dynaudio A S 8660 Skanderborg Denmark Owners Manual Excite X14A All text and image copyrights reserved Subject to change without notice www dynaudio com ...