Diamond 10kW Manual
Dynatronix, Inc.
198-1603-03 Rev 01
Page 59 of 150
displayed
“rtc min Lo”
RTC
Minutes
4 least significant
digits
“rtc min Hi”
RTC
Minutes
4 most significant
digits
“rtc Hr Lo”
RTC
Hours
4 least significant
digits
“rtc Hr Hi”
RTC
Hours
4 most significant
digits
“Atc amp min Lo”
ATC
Amp Minutes
4 least significant
digits
“Atc amp min Hi”
ATC
Amp Minutes
4 most significant
digits
“Atc amp Hr Lo”
ATC
Amp Hours
4 least significant
digits
“Atc amp Hr Hi”
ATC
Amp Hours
4 most significant
digits
“mAn”
Manual
N/A
N/A
6.6.4. Diagnostics Run Screen
The diagnostics run screen is displayed when “diAg” is selected from the “Display Select Menu”.
The diagnostics run screen shows the expected average current and the expected average
voltage readings. The expected readings are values calculated based on the output settings of
the power supply. The expected readings are compared to the actual readings to perform
tolerance checks
. The expected current reading “I.rd.1” is the expected average current output
when the power supply is regulating current. The expected voltage reading “E.rd.1” is the
expected average voltage output when the power supply is regulating voltage.
6.7. Current and Voltage Settings
When the power supply is configured for DC or Pulse output (See
6.4.3: DC Output
and
6.4.4:
Pulsed Output
) t
he current and voltage settings can be adjusted from the “Meter Run Screen”. To
view the “Meter Run Screen” press and hold both encoder switches until the display shows “diSP”
“SEL”. Then rotate the current encoder until the display shows “diSP” “mtr”. Then press the
voltage encoder to view the meters. The “Meter Run Screen” will show the voltage and current
meters (numeric values on the top and bottom display) and the SET lamp will be off. See
6.6.Run
Screens
for details on using the display select menu.
6.7.1. Voltage Setting Adjustment
From the “Meter Run Screen” press the voltage encoder switch to view and/or change the voltage
setting. When the voltage encoder switch
is pressed from the “Meter Run Screen” the voltage
setting is displayed, as indicated by the flashing SET lamp. Rotate the voltage encoder to change
the currently selected voltage setting digit. Each press of the voltage encoder switch selects the
next voltage setting digit (the blinking digit is the currently selected digit). After no changes are
made to the voltage setting for a short period of time the display will return to the voltage meter
value (the SET lamp will be off when both the current and voltage meters are displayed).
The voltage setting can be adjusted during operate or standby mode, but cannot be changed in
remote control mode (RMT lamp is on).