Dynatronics Dynatron T3 Скачать руководство пользователя страница 26

WarranTy

DYNATRON® T3™ HI-LO TREATMENT TABLE & T4™ TRACTION TABLE  |  OPERATOR’S MANUAL REV. 10 | 4/4/2018

23

Warranty

DYNATRONICS CORPORATION warrants this product to be free from factory defects in materials and workmanship under normal use from the date of 

purchase by the original owner for the periods specified as follows:  The metal frame is warranted for FIVE YEARS.  The motor is warranted for the original 

manufacturer’s warranty period of ONE YEAR.  The upholstered top is warranted for ONE YEAR against factory defects.  Other parts are warranted for 

TWO YEARS.  If this product is defective within the warranty period specified, DYNATRONICS will, subject to the conditions set forth below:

(1)  repair or replace defective parts at no charge within a reasonable period of time with new or remanufactured parts, at DYNATRONICS’ option; and

(2)  provide labor for the repair or replacement of defective parts under this warranty without charge.

Parts used for replacement under this warranty are warranted for the remainder of the original warranty period.  THE REPAIR OR REPLACEMENT OF 

DEFECTIVE PARTS SHALL CONSTITUTE THE SOLE AND EXCLUSIVE REMEDY IN THE EVENT OF A BREACH OF WARRANTY.  Dynatronics 

may specify whether the product or part must be shipped to Dynatronics for repair, or whether the repair will be performed on-site by a qualified 

technician approved by Dynatronics.

REGISTRATION REQUIRED:  In order for this warranty to be valid, the warranty registration page (included in this operator’s manual) must be filled 

out and returned to DYNATRONICS within 10 days of the date this product is delivered to the original owner.  A copy of an invoice or receipt may be 

requested to verify purchase date.

REPAIRS:  All repairs must be performed by qualified personnel.  Any modifications or repairs by unqualified parties will void this warranty.

OBTAINING WARRANTY SERVICE:  Authorization by DYNATRONICS is required before obtaining service under this warranty. Call DYNATRONICS’ 

CUSTOMER SERVICE at 1-800-874-6251 to make arrangements for warranty service.

PACKAGING AND SHIPPING:  Any item shipped to an authorized service facility for service under this warranty must be in the original shipping 

carton, freight prepaid, fully insured, and/or otherwise properly packed to prevent damage.  DYNATRONICS is not liable for any damage to the item 

while in transit.  Include a summary of the problem with the product.  Write the return authorization number obtained from DYNATRONICS on the 

shipping label.

SHIPPING COSTS:  Within the first 30 days of the warranty period, DYNATRONICS will pay all necessary shipping costs associated with obtaining 

service under this warranty.  After the first 30 days of the warranty period, the owner is responsible for all costs associated with shipping the product or 

part to an authorized service facility.  DYNATRONICS will pay all costs associated with shipping the product or part back to the owner after service is 

completed, and will ship the product using the same carrier or type of carrier and service that was used by the owner for the incoming shipment.

EXCLUSIONS:  Any defect, malfunction or failure caused by or resulting from improper installation, service, maintenance or repair, or from abuse, neglect, 

transportation, accident, act of God, or other cause beyond the control of DYNATRONICS will not be covered by this limited warranty.  ANY IMPLIED 

WARRANTIES COVERING THIS PRODUCT, INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY OR FITNESS FOR 

A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO TWO YEARS FROM THE DATE OF PURCHASE BY THE ORIGINAL OWNER.  

DYNATRONICS SHALL NOT IN ANY CASE BE LIABLE FOR SPECIAL, INCIDENTAL, CONSEQUENTIAL, INDIRECT, OR OTHER SIMILAR 

DAMAGES ARISING FROM BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, OR ANY OTHER LEGAL THEORY EVEN IF 

DYNATRONICS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.  SOME STATES DO NOT ALLOW LIMITATIONS ON HOW 

LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE 

ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.  THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY 

ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.

For more information concerning repairs, operation, or technical assistance, please contact the DYNATRONICS dealer nearest you, or contact 

DYNATRONICS directly at 1-(800) 874-6251.

Dynatronics Corporation

7030 Park Centre Drive  •  Salt Lake City, Utah  84121  •  (801)  568-7000  (800)  874-6251

Содержание Dynatron T3

Страница 1: ...O P E R A T O R S S E R V I C E M A N U A L ...

Страница 2: ...urposes It can be utilized as a treatment table with surfaces that can be adjusted to various positions or it can be used in conjunction with Traction devices and Traction accessories such as belts and harnesses to exert therapeutic pulling forces on the patient s body 890 5900 primarily for the cervical lumbar areas Inventory T34MANUAL Rev 10 ISO 13485 DNV GL NEMKO PRESAFE AS CERTIFIED Dynatron T...

Страница 3: ...g the Table Height 6 Adjusting Head and Foot Sections 6 Positioning the Patient 6 Warnings and Precautions 7 Technical Information 8 General Specifications 8 Disposal of Equipment and Accessories 8 Environmental Conditions Transport and Storage 9 Definition of Symbols and Labeling 9 Symbols and Labels 10 Cleaning Naugahyde Surfaces 10 Maintenance and Service 12 General Maintenance 12 Components an...

Страница 4: ...les include all of the standard advantages of Dynatronics engineering with meticulous attention to detail and quality producing a reliable product that will provide years of excellent performance Outstanding features include Dual Full Length Foot Switches Postural Drainage Optional Motorized Mid Section MSAS Mobilization Strap Attachment System Easy Glide Foot Section with Positive Dual Lock Conto...

Страница 5: ...nable mobility and dexterity to monitor patient responses to attended or unattended treatments Before You Treat a Patient Before administering a treatment to a patient familiarize yourself with the operating instructions as well as the contraindications warnings and precautions associated with the use of treatment tables and the associated Traction Treatments In addition to this information consul...

Страница 6: ...transport can result in damage and invalidate the warranty Complete the warranty registration form located at the back of this manual and return it to Dynatronics within 30 days of purchase This is essential to insure you are not billed for services that are covered by the warranty policy Warranty registration should include all applicable serial numbers Setup After unpacking set the table in the ...

Страница 7: ...the Nylon Washer 29 onto the Pivot Pin 28 before sliding it through center hole in the adjustment plate 4 Continue sliding the Pivot Pin through the lower traction arm Pivot Pin hole 5 Attach the second nylon washer 29 6 Slide the Pivot Pin through the hole in the Lower frame 7 Securely tighten the Nylon Lock Nut 30 to the end of the Pivot Pin 28 Do not over tighten the Nylon Lock Nut 30 When it f...

Страница 8: ...ical Specifications Surface dimensions Width 28 wide Length without Traction arm 81 long Length with Traction arm 105 long T4 Elevation Table Adjustments Head Section Raises to 40 Lowers to 80 Foot Section Raises to 85 Surface Height Adjusts from 17 5 to 39 Casters 4 two way locking casters Controls Electric Foot Bar Capacity 500 lbs Shipping Weight 348 lbs T3 385 lbs T4 Shipping Boxed Dimensions ...

Страница 9: ...ction Lever moves counterclockwise As long as the lever is down the section will continue to move down When the handle is released the section will securely remain in place Positioning the Patient Ambulatory Patients Verify that the casters are locked before positioning the patient Adjust table height so that the patient platform is just below the patient s buttocks The patient should always be se...

Страница 10: ...the patient prior to making any adjustments to the table while the patient is positioned on the table 5 DO NOT change the angle of any section while the patient s weight is on that section 6 ALWAYS keep children away from the table 7 DANGER Risk of explosion hazard if used in the presence of flammable anesthetics 8 Verify that the casters are locked before treating the patient WARNING PINCH POINTS...

Страница 11: ... Maximum Leakage 100 µa or less Typ 18 µa Grounding Characteristics Resistance from ground pin on power plug to exposed metal surfaces 1 Ohm or less Typ 08 Ohms Disposal of Equipment and Accessories There is no risk posed in disposal of this equipment or its accessories This product contains no hazardous materials CAUTION To ensure proper mechanical operation a daily check and preliminary operatio...

Страница 12: ...the following ranges a an ambient temperature range of 40 C b a relative humidity range of 10 to 100 including condensation c an atmospheric pressure range of 500 hPa to 1060 hPa Definition of Symbols and Labeling Some or all of the following symbols are included in the labeling for this device Definitions accompany each symbol Caution Warning Follow Instructions for Use Made in USA Temperature Mo...

Страница 13: ... Engineered Products offers the following cleaning instructions for their Naugahyde products Naugahyde with Advance BeautyGard has been formulated to achieve a superior level of disinfectability with disinfectant products containing sodium hypochlorite common household bleach diluted 1 10 Dampen a soft white cloth with a solution of household bleach sodium hypochlorite 10 bleach 90 water Rub gentl...

Страница 14: ...E T4 TRACTION TABLE OPERATOR S MANUAL REV 10 4 4 2018 11 Unapproved Cleaning Solutions Strong Phenols Phenol Alcohol Combinations Sodium Hypochlorite Household Bleach Sodium Bromide Citric Acids Iodophors Ammonium Chloride Accelerated Hydrogen Peroxide 0 5 ...

Страница 15: ...ent at 1 800 874 6251 NOTE Only technically qualified personnel should attempt to service or repair this equipment GENERAL MAINTENANCE If the bed is located in an area where it is subject to extreme amounts of moisture humidity or dust the pivot joints and sliding surfaces should be cleaned and lubricated WARNINGS An electric shock hazard may exist when electrical covers have been removed In addit...

Страница 16: ...asters 11 T34MPH Main Plug in Housing 12 40 106 Magnetic Motor Max 65 Main Motor 13 40 106 B Magnetic Mid Lift Motor Max 10 14 T34MSL Mid Lift Switch Left 15 T34MSR Mid Lift Switch Right 16 DP000088 Mid Section Gatch Mechanism Spring 17 DP000061 Master Gatch Mechanism Wieldment controls all three sections 18 T4FOOTSWITCH Foot Switches 19 T34FSC Foot Switch Cable 20 DP000084 Slide Rack Block Assemb...

Страница 17: ...n 3 T4 TOP color B Top Mid Section 4 T4 TOP color C Top Foot Section 5 DT4PB Pull Bar 6 DTKNOB Lift back Handle black 7 T4SLIDELOCKHANDLE Traction Arm Handle and Sliding Mechanism 8 DP000075 Mobilization Strap Attachment System Chrome Bar 9 DP000072 Foot Switch Bar 10 DTCAS Two Way Locking Casters 11 T34MPH Main Plug in Housing 12 Pinch Point Labels Warning Pinch Points See part numbers and diagra...

Страница 18: ...2 40 106 Magnetic Motor Max 65 Main Motor 12 40 106 A Magnetic Motor Max 63 Main Motor used in conjunction with Mid Lift Motor in place of the Max 65 13 40 106 B Magnetic Mid Lift Motor Max 10 REF Right T3 Table with Mid Lift Motor Both the T3 and T4 Traction Tables are available with the Mid Lift Motor Left T4 Traction Table with standard main Motor ...

Страница 19: ...rs View A Description 3 T4 TOP color B Top Mid Section 13 40 106 B Magnetic Mid Lift Motor Max 10 14 T34MSL Mid Lift Switch Left 16 35 005 Mid Section Gatch Mechanism Spring 17 DP000061 Master Gatch Mechanism Wieldment controls all three sections REF View A enhancement with Mid Lift Motor View A enhancement without Mid Lift Motor ...

Страница 20: ...ATOR S MANUAL REV 10 4 4 2018 17 No Part Numbers View B Description 9 DP000072 Foot Switch Bar 16 DP000088 Mid Section Gatch Mechanism Spring 18 T4FOOTSWITCH Foot Switches 19 T34FSC Foot Switch Cable REF View B location of Z Spring applicable to both the T3 and the T4 tables Detail B ...

Страница 21: ...E Description 7 T4SLIDELOCKHANDLE Traction Arm Handle and Sliding Mechanism 20 DP000084 Slide Rack Block Assembly 21 HW000022 3 16 x 1 Grooved Clevis Pin 22 HW000187 3 16 Push Nut 23 HW000171 12mm OD x 4 88mm ID x 1mm Thick Washer 24 DP000080 Bent Lock Hinge 25 DP000082 Slide Lock Shaft 26 DP000112 Slide Lock Shaft Spring REF Detail D Detail E ...

Страница 22: ...OR S MANUAL REV 10 4 4 2018 19 No Part Numbers Views F Description 14 T34MSL Mid Lift Switch Left 15 T34MSR Mid Lift Switch Right 30 HW000017 3 8 16 Nylon Lock Nut 31 DP000106 Gatch Lock Spring with Mid Lift Motor only REF Detail F T4 with Mid Lift Motor Detail F T3 with Mid Lift Motor ...

Страница 23: ...N TABLE OPERATOR S MANUAL REV 10 4 4 2018 20 No Part Numbers Views G H Description 27 DP000006 Traction Arm Assembly long 28 DP000099 Traction Arm Pivot Pin 29 HW000071 Nylon Washer 375 x 875 x 083 30 HW000017 3 8 16 Nylon Lock Nut REF View locations G H Detail G Detail H ...

Страница 24: ...calling Dynatronics Customer Service to obtain an SVO or RMA 1 User name and address 2 User phone number 3 Serial number of the unit 4 A description of the problem with the unit After receiving the Service Order Number SVO or Return Material Authorization Number RMA write the number clearly on the outside of the shipping container Packaging and Shipping of Replacement Parts All defective or broken...

Страница 25: ...e information that reasonably suggests a probability that a device caused or contributed to a death b serious injury or c serious illness If you receive information that reasonably suggests a device malfunction and a recurrence will probably cause a death b serious injury or c serious illness Definition of Serious Injury A serious injury is an injury that 1 is life threatening 2 results in permane...

Страница 26: ...rvice under this warranty must be in the original shipping carton freight prepaid fully insured and or otherwise properly packed to prevent damage DYNATRONICS is not liable for any damage to the item while in transit Include a summary of the problem with the product Write the return authorization number obtained from DYNATRONICS on the shipping label SHIPPING COSTS Within the first 30 days of the ...

Страница 27: ...tative I have read and understand the information contained in the operator s manual for this device I have received in service training from my dealer and or Dynatronics for the operation of this device IMPORTANT If there is anything about the operation or use of your Dynatronics product that you do not understand contact your dealer or Dynatronics for instruction As a trained medical practitione...