Spa Operator’s Guide
Sec1:68
TROUBLE SHOOTING GUIDE (CONT.)
Note: These motors will feel hot to the touch. This is normal.
The Overheat Sensor will turn the motor off if there is an over-
load or high temperature problem.
NOTE!
Spa is leaking
Probable Cause #1 .............Loose connection.
Action..................................Hand tighten all disconnects and fittings.
Check joints and unions.
Motor does not run
Probable Cause #1 .............No power to motor.
Action..................................Check power switches and circuit breakers.
Check motor plug where plugged into control box.
Probable Cause #2 .............Pump jammed from foreign matter in impeller.
Action..................................Call dealer for recommended action.
Probable Cause #3 .............Motor overheats on hot days while filtering.
Action..................................Reprogram your controls to cycle during the
coolest parts of the day and on shorter cycles.
(see programming instructions).
Motor runs hot
Probable Cause #1 .............Pump ran dry.
Action..................................Call dealer for recommended action.
Probable Cause #2 .............Restricted suction lines.
Action..................................Make sure all valves are open/clear suction of debris.
Probable Cause #3 .............Improper ventilation
Action..................................Insure that vents on side of spa are free and clear
of any debris or landscaping. Spa should also be
located an adequate distance from any walls or
fencing for good ventilation.
Stereo Issues ....................Please refer to manual (provided)
TV issues ...........................Please refer to manual (provided)
Содержание Spa & Hot Tub 2016
Страница 2: ......
Страница 64: ...Spa Operator s Guide Sec1 62...
Страница 68: ...Spa Operator s Guide Sec1 66...
Страница 71: ...Spa Operator s Guide Sec1 69 NOTES...
Страница 72: ...Spa Operator s Guide Sec1 70 NOTES...
Страница 74: ...Spa Operator s Guide Sec1 72...
Страница 75: ...Spa Operator s Guide Sec1 73...