background image

AMP 331 Instructions for Users 

Dynastream Innovations Inc. 

DOCUMENT NO: 

D00000381 Rev. 0.E

 

SHEET:  

7 of 7

 

 

a.  To upload the data immediately, press and hold both buttons simultaneously for 1 s until the pod 

displays “UPLd”.  Once the pod is in upload mode, follow the instructions in AMP Ware 
(Section 5.3) for uploading the data to the PC. 

b.  To upload the data later, press and hold the right button to turn the unit off.  When the unit is 

turned back on it will go immediately to “DATA” mode.  Follow the instructions above for 
uploading. 

c.  To clear the data from the pod memory, press and hold the left button.  The pod will display 

“CLR” once the data has been cleared.  It will then scroll through the date and time before 
displaying “PUSH 

START

”, indicating that it is ready to start data collection.  See Step 4 for 

instructions on data collection. 

 

6.  To turn the unit off, press and hold the right button until the LCD displays “OFF”. 

 
 

3.2    Pod Power Supply 

 

3.2.1  Battery Life 

The pod is powered by a single AAA battery.   The maximum duration of data collection depends on the 
activity level of the user and the type of battery however a fresh battery should allow for at least 7 days of 
continuous data collection.   
 

3.2.2  Battery Replacement 

To replace the battery, open the door on the bottom side of the pod using a coin.  If the door does not spring 
open then knock the bottom corner of the pod, near the door, on a firm surface until the door opens and the 
battery falls out.  Insert a new battery with the positive terminal pointing out (as shown by the “+” sign on the 
hatch).   
 

3.2.3  Loss of Power 

If the battery runs out during data collection the LCD will go blank.  When this occurs, the data collected until 
that time is saved in the pod.  To upload the data to the PC, replace the battery then turn the pod on.  It will 
display “DATA” indicating there is data in the memory waiting to be uploaded. 

Содержание AMP 331

Страница 1: ...s for Users D00000381 Rev 0 E Dynastream Innovations Inc 228 River Avenue Cochrane Alberta T4C 2C1 www dynastream com p 403 932 9292 f 403 932 6521 June 12 2003 Contact Anne Gildenhuys Product Manager...

Страница 2: ...by any means including electronic storage reproduction execution or transmission without the prior written consent of Dynastream Innovations Inc The recipient of this document by its retention and us...

Страница 3: ...ECHNICAL INFORMATION 4 2 COMPONENTS OF AMP 331 5 3 AMP POD 6 3 1 POD USER INTERFACE 6 3 2 POD POWER SUPPLY 7 4 AMP ANKLE SLEEVE 8 4 1 STARTING DATA COLLECTION 8 4 2 INSTRUCTIONS FOR TESTSUBJECTS 9 4 3...

Страница 4: ...accept any interference received including interference that may cause undesired operation The abbreviation IC before the registration number signifies that registration was performed based on a Decla...

Страница 5: ...e sleeve attached to the lower leg just above the ankle holds the pod in the correct position and orientation to enable accurate activity monitoring AMP Link The Link connects to the USB port of a PC...

Страница 6: ...ts of the year the months of the year and the digits in the date and time ii Use the left button to move to the next digit or next selection b When the time and date have been set the pod will display...

Страница 7: ...o turn the unit off press and hold the right button until the LCD displays OFF 3 2 Pod Power Supply 3 2 1 Battery Life The pod is powered by a single AAA battery The maximum duration of data collectio...

Страница 8: ...LCD is visible in the circular window Close the triangular flap to keep the pod in 3 Use the Velcro strap to attach the pod on the back of the leg just above the ankle It is best to tighten the strap...

Страница 9: ...be re attached correctly The test subject should be instructed to Ensure that the ankle sleeve is right side up by checking that the Dynastream logo is not upside down and that the flap covering the p...

Страница 10: ...k 1 Plug the AMP Link into the USB port of your computer Position the link at least two feet from the computer monitor 2 The PC will detect the Link and will automatically open a window with the headi...

Страница 11: ...downloaded to an MS Excel workbook where macros are used to format and display the data In order for AMP Ware to be able to run these macros the security settings in Excel must be set appropriately Pl...

Страница 12: ...re that the AMP Link is plugged into the USB port and that it is breathing 7 Click on the DOWNLOAD button on the Trial Information window in AMP Ware 8 Messages regarding the download progress will ap...

Страница 13: ...button at the top and then close the window This feature can also be used to create and save subject information profiles for later use 6 3 4 Desired Output The Desired Output field in the Trial Infor...

Страница 14: ...only select the Trusted Sources tab on the same dialog box as above and select the checkbox that says Trust access to Visual Basic Project If Excel is already open make sure that control is not withi...

Страница 15: ...time it is turned on it will still be in DATA mode ready for downloading However you cannot collect new data until the old data is cleared off the pod The dates and or times in the Excel workbook do...

Отзывы: