![Dynaset GENSCO HMAG PRO 1200-49 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/dynaset/gensco-hmag-pro-1200-49/gensco-hmag-pro-1200-49_user-manual_2548775025.webp)
26
Dynaset Oy | Menotie 3, 33470 Ylöjärvi | puh. 03 3488 200 | [email protected] | www.dynaset.com
HYDRAULIC MAGNETS
OPERATION
ATTENTION!
Do not drag the HMAG PRO along the ground. Draging it might damage
and cause wearing on the HMAG PRO.
5.2. OVERHEATING AND OVERLOAD SITUATION
HMAG PRO’s generator is equipped with a temperature switch (O.HEA on the
display). In overheating situations control electronics prevent the HMAG PRO to
re-energize magnet until the HMAG PRO has cooled down.
Pictures 14: O.HEA on the Display
When temperature switch trips the magnetisation should be switched off in order
to cool HMAG PRO’s generator as fast as possible.
After the HMAG PRO has cooled enough the unit automatically switches the
overheat alarm off and HMAG PRO is operatable again.
ATTENTION!
Standard HMAG PRO magnet’s load duty is 60%. Exceeding the ED-value
causes magnet to heat up faster !
5.3. AMBIENT TEMPERATURE
To avoid power loss, it is not recommended to use HMAG PRO when the ambient
temperature exceeds +40 ºC. When the ambient temperature exceeds +40 ºC
power takeoff should be limited in accordance with the diagram,in picture 15. For
instance, at the ambient temperature of +50 ºC the power takeoff should not be
more that 80 % of the maximum.
NOTE!
HMAG PRO ED100% model can handle higher than +40
ºC
ambient
temperatures without overheating.