1.3 Specifications

STANDARD OPERATING CHARACTERISTICS

Code: Incremental

Pulses per Revolution: 1024

Phasing Sense: A leads B for Counter-Clockwise
rotation (CCW) viewing encoder-mounted end

Quadrature Phasing: 90

°

 

±

22

°

Symmetry: 180

°

 

±

 54

°

Index: 180

°

 to 2160

°

ELECTRICAL

Input Voltage Requirement: 5-24V DC

Current Requirement: 50 mA

Output Signals:

5-17 V Line Driver, 150mA

Frequency Response: 0 - 120kHz  Data & Index

Electrical Immunity: 2kV ESD, Reverse Polarity,
Short Circuit

Connector: 10 pin industrial duty latching, sealed
NEMA 4 &12, IP65 with gold pins

E

LECTRICAL CONNECTIONS

MECHANICAL

Shaft Speed: 5,000 RPM

Mounting Configuration: 4.5”  56C face mount
for NEMA MG1 standards

Housing Material: Cast Aluminum

Acceleration Rate: 12,000 rpm/sec max

Shaft Length Required: 0.7” min

Allowable Shaft End-Play: 

±

 0.045”

Wheel Bore: 1-1/8” with keyway or 15/16”

Weight: 2.8 lbs (1.3 kg)

ENVIRONMENTAL

Operating Temperature Range:

Standard: -40

°

C to +130

°

C

See Table Below

Storage Temperature Range: -40

°

C to +130

°

C

Humidity: to 98% RH (non-condensing)

Shock (Sensor Module): 1 meter drop test,
30 G’s Min

Vibration: 18 G’s @ 5-2000 Hz spectrum

100

105

110

115

120

125

130

135

24

 V

D

C

21

 V

D

C

18

 V

D

C

15

 V

D

C

5 V

D

C

Safe Operating Area

Deg. C

SAFE TEMPERATURE RANGE

Specifications subject to change without notice

Common
B
A
Z
No Connection
Vcc (5-15 VDC)

B

A

Z
Shield

1
2
3
4
5
6
7
8
9
10

Signal

    Connector Pin

Patent Pending

Содержание NorthStar WIND 56

Страница 1: ...Instruction Manual WIND 56 Magnetoresistive Encoder for Pitch Control Unit Applications 702820 0001 REV C brand NorthStarTM Patent Pending...

Страница 2: ...DYNAPAR 1 800 873 8731 702820 0001 Rev C June 2012 NorthStar WIND 56 Instruction Manual Page 2...

Страница 3: ...ation 9 2 3 Electrical Installation 10 2 4 Returning NorthStar brand Equipment to Dynapar 11 Methods and apparatus disclosed and described herein have been developed solely on company funds of Dynapar...

Страница 4: ...ings have been disconnected and secured from all electrical power sources and 3 all accessory devices associates with the work area have been de energized If high potential insulation test is required...

Страница 5: ...ve encoder sensor based unit has been designed for fast easy mounting onto a standard NEMA 56C motor face The basic design philoso phy is as follows The encoder frame is mounted onto the C face flange...

Страница 6: ...CTRICAL CONNECTIONS MECHANICAL Shaft Speed 5 000 RPM Mounting Configuration 4 5 56C face mount for NEMA MG1 standards Housing Material Cast Aluminum Acceleration Rate 12 000 rpm sec max Shaft Length R...

Страница 7: ...ile proper claims promptly with the carrier and insurance company Please advise us of such filing In case of parts shortages advise us immediately Dynapar cannot be responsible for any missing parts u...

Страница 8: ...ch to tighten the screws to a nominal 25 in lbs 2 Install Encoder Housing Orient the encoder frame so the 4 5 inch I D surface will fit over the 4 5 inch C flange encapsulated side toward the motor Do...

Страница 9: ...0001 Rev C June 2012 NorthStar WIND 56 Instruction Manual Page 9 Shown with customer supplied mating connector NOTE Be sure This Side Out is visible on the face of the pulse wheel after installation F...

Страница 10: ...any wires without insulation For lengths over 100 feet use 18 gage or larger to a maximum of 1000 feet If shielded twisted pair wire is used do not cross channels Keep each pair of complementary chan...

Страница 11: ...r must be obtained from a factory representative before returning the equipment to our service department When returning an instrument for service the following information must be provided before we...

Страница 12: ...DYNAPAR 1 800 873 8731 702820 0001 Rev C June 2012 NorthStar WIND 56 Instruction Manual Page 12...

Отзывы: