Dynamic Flow Computers
SFC332L Manual
Data Entry
— 2-36
Date: 8/1/2019
HISTORICAL DATA
VIEW, CAPTURE AND STORE
To retrieve historical data, go to
Historical Data
menu. The
View
option retrieves the data from the flow
computer but does not store the information into the database. The second option,
Capture and Store
,
retrieves the information, shows it on the screen and stores it on the database.
The available types of reports are:
P
R E V I O U S
H
O U R L Y
D
A T A
Up to 50 previous hour data are stored in the Flow Computer. Enter first report and the Flow Computer will
go backward from that selected report. Current hour cannot be selected.
P
R E V I O U S
D
A I L Y
D
A T A
Up to 50 previous daily reports can be retrieved.
A
L A R M
R
E P O R T
Up to 100 previous alarm data can be retrieved. The data are starting from the most recent to the oldest.
A
U D I T
R
E P O R T
The audit trail report shows configuration parameter that has changed which could influence the calculated
numbers. The Flow Computer provides up to 100 event logs. One purpose for audit trail is to back track
calculation errors that result from mistakes by the operator of the flow computer operator
.
B
A T C H
R
E P O R T
Up to 50 previous batch reports can be retrieved.
Viewing previously captured reports
Once a report is stored in the database using the
Historical Data | Capture and Store
option it
can be seen using the
Previously Captured Reports
option under the Historical Data Menu.
When the option is selected, a dialog will appear asking for the name of the report you want to
see. There is a “View last captured report” option than will show the data acquired the last time
from a device. If you want to see another report different than the last one just type the name of
the report in the space provided. The browse button can be used to see the list of reports stored in
the database.
Содержание SFC332L
Страница 9: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 4 Date 8 1 2019 SFC332L Flow Computer Dimensions ...
Страница 15: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 10 Date 8 1 2019 Memory Jumper ...
Страница 17: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 12 Date 8 1 2019 ...
Страница 18: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 13 Date 8 1 2019 ...
Страница 22: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 17 Date 8 1 2019 Wiring the analog inputs 1 4 ...
Страница 26: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 21 Date 8 1 2019 TURBINE SINE WAVE ...
Страница 35: ...Dynamic Flow Computers SFC332L Manual Quick Start 1 30 Date 8 1 2019 ...