3.1
The DX BUS cable
Cable specifications - straight cable
The part number of the straight cable is GSM630YY, where YY = the length in 100 mm.
DX BUS cable straight
Length
Part/Order number
300 mm
1 ft
GSM63003
500 mm
1' 8"
GSM63005
1.0 m
3' 3"
GSM63010
1.5 m
4' 11"
GSM63015
2.0 m
6' 7"
GSM63020
2.5 m
8' 2"
GSM63025
DX BUS cable with Ferrite bead to improve EMC
2.0 m
6' 7"
GSM63020F
GBK60348
: Issue 1 – October 2007
26
Parameter
Value
Contact Resistance (per contact)
As per IEC 512-2, Positronic
3 m
Ω
nom, 7 m
Ω
max
Wire resistance @ 20°C
DXB+
DXB-
15.1 m
Ω
/m, 4.6 m
Ω
/ft
8.5 m
Ω
/m, 2.6 m
Ω
/ft
Operating Current (DXB+/DXB-)
12 A nom, 20 A RMS max
Connector Latch Holding Force
40 N min
Cable Strain
100 N max (accidental, non-repetitive)
Cable Flex Force
10 N max
Minimum Cable Bend Radius
Flexing values for (T > –10°C/14°F)
10 mm / 0.39 inch - fixed installation
25 mm / 1 inch
- occasional flexing
50 mm / 2 inch
- frequent flexing
Operating Temperature
(ambient, fixed installation)
–25°C to +50°C
–13°F to +122°F
Cable Temperature Rating
80°C / 176°F (internal operating temp)
Warning:
The specified bend/flex radiuses are minimum values and must be
considered as a guideline only. Where frequent flexing is part of the
intended application, the installer must ensure an appropriate
bend/flex radius for the intended and foreseeable environmental
conditions. Extreme cold temperatures considerably reduce cable
flexibility. Appropriate life testing must be carried out to
determine/confirm the expected service life and inspection and
maintenance schedule.
35
YY x 100 ± 10
Ø7.0
13 x 16
R
-B
EN
D