background image

certified electrician. If the power cord is damaged, please contact Customer 
Support. 

16. Do not use the sauna during an electrical storm to avoid risk of shock or injury. 
17. Do not continuously switch the power ON and OFF excessively as it will 

compromise the life of the electrical components. 

18. Your hands must be dry and free of moisture before plugging and unplugging cords 

and wiring harnesses from the power supply and circuit boards. Never operate the 
sauna with wet hands or wet feet to avoid the risk of electrical shock or injury.  
Never touch the metal prongs of the plug. 

19. Do not attempt to make any repairs yourself unless authorized by the manufacturer 

or its agent. If a problem occurs with the sauna, please contact the manufacturer or 
its agent immediately to avoid safety risks. Unauthorized repair attempts will void 
the manufacturer’s warranty. 

20. Please make sure the outlet power supply meets the specifications required.    

Failure to meet the requirements may cause safety risks. 

21. Some sauna models are equipped with reading and/or roof lamps. Because the 

lamp temperature will become very hot once powered ON, do not attempt to touch 
the lamp to avoid being burned. Do not attempt to touch it for at least 20 minutes or 
until it cools down completely if a need to touch it arises. 

22. Do not pour water or any other liquids onto the infrared heat emitters. Do not bump, 

hit, or break the heating elements as it may cause an electrical short and pose a 
safety risk. 

23. Do not make any modifications to the sauna, the sauna structure, or the sauna 

components. 

24. Prior to each sauna session, the sauna room is to be inspected for correct 

operation. If for any reason your sauna does not seem to be operating properly, 
discontinue use and contact Customer Service. 
 

 

 

Safeguards For Your Sauna 

1.  Do not install the sauna near water, near a bathtub (if water will splash on the 

sauna), near a shower (if water will splash on the sauna), in a wet basement, or 
near a swimming pool (if water will splash on the sauna). 

2.  Do not use liquid cleaners or aerosol cleaners on the sauna. Unplug the sauna 

from the wall outlet before cleaning. Use plain water and a soft damp cloth for 
cleaning. 

3.  The power supply cord should be routed so that it is not walked on or pinched by 

any object that may be placed against it. 

4.  When replacement parts are required, be sure they meet the specified 

requirements of the manufacturer. Unauthorized substitutes may result in a fire, 
electrical shock, or other hazardous situations. After any repairs, please ask the 
service technician to perform a safety check to determine that the sauna is in good 
working order. 
 

Page 25 

Содержание DYN-6108-01

Страница 1: ...UNAS ARE FOR INDOOR USE ONLY 120VAC 15AMP Dedicated Circuit Required 1 2 Person Models 120VAC 20AMP Dedicated Circuit Required 3 Person Models Carefully and thoroughly read this Owner s Manual before...

Страница 2: ...organic substances such as the human body two to three inches so that the warming effect is very uniform Health Benefits Because infrared rays penetrate the body through conversion there is a deep hea...

Страница 3: ...c fields Electric and magnetic fields are a basic force of nature like gravity generated by electricity They are found almost everywhere Electric and magnetic fields are found in nature where they are...

Страница 4: ...ealth Administration OSHA have established permissible exposure limits PEL Currently there is no consensus on the potential health hazard from any exposure to EMF The mainstream scientific evidence su...

Страница 5: ...TRUCTIONS THOROUGHLY BEFORE ASSEMBLY DYN 6108 01 THE ABOVE ASSEMBLY DIAGRAM IS FOR A QUICK REFERENCE VISUAL GUIDE ONLY ALL SAUNA MODELS MAY NOT BE SHOWN PARTS AND ACCESSORIES DO VARY AND ARE SUBJECT T...

Страница 6: ...TRUCTIONS THOROUGHLY BEFORE ASSEMBLY DYN 6208 01 THE ABOVE ASSEMBLY DIAGRAM IS FOR A QUICK REFERENCE VISUAL GUIDE ONLY ALL SAUNA MODELS MAY NOT BE SHOWN PARTS AND ACCESSORIES DO VARY AND ARE SUBJECT T...

Страница 7: ...TRUCTIONS THOROUGHLY BEFORE ASSEMBLY DYN 6308 01 THE ABOVE ASSEMBLY DIAGRAM IS FOR A QUICK REFERENCE VISUAL GUIDE ONLY ALL SAUNA MODELS MAY NOT BE SHOWN PARTS AND ACCESSORIES DO VARY AND ARE SUBJECT T...

Страница 8: ...eshooting and replacement parts 1 Product Introduction The infrared sauna room is composed of a wood cabin infrared heat emitters and a control system The wood cabin includes a FRONT PANEL REAR PANEL...

Страница 9: ...THOROUGHLY BEFORE ASSEMBLY PARTS DESCRIPTION DYN 6108 01 THE ABOVE ASSEMBLY DIAGRAM IS FOR A QUICK REFERENCE VISUAL GUIDE ONLY ALL SAUNA MODELS MAY NOT BE SHOWN PARTS AND ACCESSORIES DO VARY AND ARE...

Страница 10: ...THOROUGHLY BEFORE ASSEMBLY PARTS DESCRIPTION DYN 6208 01 THE ABOVE ASSEMBLY DIAGRAM IS FOR A QUICK REFERENCE VISUAL GUIDE ONLY ALL SAUNA MODELS MAY NOT BE SHOWN PARTS AND ACCESSORIES DO VARY AND ARE...

Страница 11: ...THOROUGHLY BEFORE ASSEMBLY PARTS DESCRIPTION DYN 6308 01 THE ABOVE ASSEMBLY DIAGRAM IS FOR A QUICK REFERENCE VISUAL GUIDE ONLY ALL SAUNA MODELS MAY NOT BE SHOWN PARTS AND ACCESSORIES DO VARY AND ARE...

Страница 12: ...r Cord Main power cord connects the POWER SUPPLY to the dedicated wall outlet HT1 HT2 HT3 HT4 HT5 HT6 Heater cords connect the heat emitters to the POWER SUPPLY at these ports HT5 HT6 are not used on...

Страница 13: ...oom for your listening pleasure see Figure 2 Figure 2 IV Buckles A External Buckles The external buckles are used to connect the LEFT and RIGHT SIDE PANELS to the REAR PANEL see Figure 3 Figure 3 B Gu...

Страница 14: ...mitter s on the topside of the FLOOR PANEL see Figure 5 B Understanding the Difference Between the Top and Bottom of the Wall Panels The 4 panels are in the upright position when the moldings are at t...

Страница 15: ...bly Instructions 1 Choose a good location to assembly the sauna a The location must be dry level and away from any source of water b The dedicated outlet must be easily accessible c Two adults will be...

Страница 16: ...brackets are engaged the RIGHT SIDE PANEL will need to be pulled downward until the top of both wall panels is flush Please see Figure 9 Figure 10 shows the guide and guide insert brackets Please note...

Страница 17: ...6 Installing the BENCH HEAT EMITTER PANEL and BENCH A Installing the BENCH HEAT EMITTER PANEL can be a little tricky You will need to slide the BENCH HEAT EMITTER PANEL into place at an angle as indi...

Страница 18: ...erior door handle portion The screws will be used to mount the door handle to the glass door 8 Installing the ROOF PANEL A The side of the ROOF PANEL with the ceiling vent will be situated towards the...

Страница 19: ...onnectors the MP3 connector and the CTRL Panel Control harness wire connector see Figure 17 Before Connecting Figure 16 After Connecting Figure 17 10 Installing the TEMPERATURE SENSOR A Enter the saun...

Страница 20: ...ce the ROOF DUST COVER over the top of the ROOF PANEL Be cautious when pulling the power cord through the hole in the ROOF DUST COVER When the edges are aligned screw the ROOF DUST COVER into place Th...

Страница 21: ...during and after sauna use to prevent dehydration since body fluids will be lost through perspiration It is not recommended to shower immediately after use since the pores in your skin will be open a...

Страница 22: ...ce and the control panel will stop flashing and heat will began coming from the emitters once again 5 Heating times do vary Generally it will take approximately twenty to thirty minutes to preheat the...

Страница 23: ...ng and you choose to use the Aux Wire to connect to the speaker system If you need to reset the Bluetooth Aux system you can do so by unplugging the sauna s power cord for 15 minutes 10 Please Note On...

Страница 24: ...and also to avoid having too much perspiration dripping onto the floor heater If your legs become cold you can use a third towel to drape over your legs to trap the heat 5 At the first sign of a cold...

Страница 25: ...ical injuries 8 Persons suffering from obesity or with a medical history of heart disease low or high blood pressure circulatory system problems diabetes or other medical conditions should consult wit...

Страница 26: ...east 20 minutes or until it cools down completely if a need to touch it arises 22 Do not pour water or any other liquids onto the infrared heat emitters Do not bump hit or break the heating elements a...

Страница 27: ...he bench if applicable Go to the roof and also check that the heat emitter cords are properly connected snug and tight to the cords on the roof and that those cords are properly plugged into the power...

Страница 28: ...od frame holding the control panel in place to gain access to the CTRL connection behind the control panel Once you remove the control panel from the wall panel you can disconnect and reconnect the co...

Страница 29: ...we assume both control panels are displaying this If so then it means there is a communication issue between the control panel power supply and temperature sensor Please proceed to the following Step...

Страница 30: ...connected to a GFCI due to the amount of power the sauna uses We have had customers who have connected their sauna to a GFCI protected outlet for the first time or for many months and then all of a su...

Страница 31: ...ixture Please go up to the roof panel and disconnect the wire connection on the topside of the light fixture Then reconnect the wire connection making sure that it is snug and tight Return back to the...

Страница 32: ...there is no heat being produced then we know it is not working properly and you will need to contact Customer Service You can also check the floor heat emitter by touching the heat emitter cautiously...

Страница 33: ...ng or forgery of proof of purchase documents will be cause to VOID this limited warranty Products on which the serial number has been defaced or removed is not eligible for warranty service Warranty L...

Страница 34: ...PAGE INTENTIONALLY LEFT BLANK Page 33...

Страница 35: ...es receipt showing date of purchase as this will serve as proof of purchase Warranty will be VOID if the following warranty card is not mailed back within 60 days of purchase date along with proof of...

Отзывы: