Dynamic Engineering PMC-UNIV-TEST Скачать руководство пользователя страница 8

           

Embedded  Solutions  

          Page  8

 

 

Construction and Reliability

 

 

PMC-UNIV-TEST is constructed out of 0.062 inch thick high temp RoHS compliant FR4 
material.   
 
Surface mounted components are used.  The connectors are SMT for the PMC bus and 
through hole for the testpoints and IO. 
 
The PMC Module connectors are keyed and shrouded with Gold plated pins on both 
plugs and receptacles. They are rated at 1 Amp per pin, 200 insertion cycles minimum. 
These connectors make consistent, correct insertion easy and reliable.  With careful 
installation the connectors will last longer and jambing on will result in a shorter lifespan. 
 
The PMC Module is secured against the carrier with the PMC connectors.  It is 
recommended, for enhanced security, that the PMC mounting screws are installed.  The 
screws and stand-off’s are supplied with the PMC from the OEM.  Dynamic Engineering 
has screws, standoffs, blank bezels and other PMC hardware available at a reasonable 
cost if your PMC was not shipped with some of the required attachment hardware or if it 
has been misplaced. 

Thermal Considerations

 

If the PMC installed has a large heat dissipation; forced air cooling is recommended. 
Since the PMC is vertical and the lid is off the box, standard air-flow may need to be 
enhanced.

Содержание PMC-UNIV-TEST

Страница 1: ...Suite C Santa Cruz CA 95060 831 457 8891 Fax 831 457 4793 http www dyneng com sales dyneng com Est 1988 User Manual PMC UNIV TEST PMC UNIV TEST ENG Revision A1 Revised 9 24 18 Corresponding Hardware R...

Страница 2: ...the product described in this document at any time and without notice Furthermore Dynamic Engineering assumes no liability arising out of the application or use of the device described herein The ele...

Страница 3: ...IO Interface Pin Assignment 7 Construction and Reliability 8 Thermal Considerations 8 WARRANTY AND REPAIR 9 Service Policy 9 Out of Warranty Repairs 9 For Service Contact 9 SPECIFICATIONS 10 ORDER INF...

Страница 4: ...n a PCI position the B side is forward the A side is the rear PMC UNIV TEST has the Host carrier side connectors mounted to the A side The PMC will have it s main component side forward in this config...

Страница 5: ...UNIV TEST ENG B Front side with the PMC type connectors plugs into host A Rear side with carrier type connectors to mate to PMC Note headers are this side for the ENG configuration as it will be up to...

Страница 6: ...Some names are truncated to allow larger easier to read print JTAG TRST TDI TDO TMST TCK plus a 3 3V and a Ground reference to interface with the installed PMC via the JTAG signals GND 8 Ground testpo...

Страница 7: ...0 9 10 5 6 11 12 41 42 13 14 7 8 15 16 43 44 17 18 9 10 19 20 45 46 21 22 11 12 23 24 47 48 25 26 13 14 27 28 49 50 29 30 15 16 31 32 51 52 33 34 17 18 35 36 53 54 37 38 19 20 39 40 55 56 41 42 21 22...

Страница 8: ...tion the connectors will last longer and jambing on will result in a shorter lifespan The PMC Module is secured against the carrier with the PMC connectors It is recommended for enhanced security that...

Страница 9: ...st accompany the return Dynamic Engineering will not be responsible for damages due to improper packaging of returned items For service on Dynamic Engineering Products not purchased directly from Dyna...

Страница 10: ...ates as PCI signals are matched and controlled Software Interface Passive no SW required for adapter Testpoints PCI signals plus JTAG and grounds Interface PMC front bezel directly rear IO via SCSI co...

Страница 11: ...ted to Pn4 for rear IO applications ROHS ROHS compliant parts and process ENG add second connector set remove SCSI switch headers to A side http www dyneng com PMC UNIV TEST html HDEterm68 http www dy...

Отзывы: