Dynamic Engineering PMC-UNIV-TEST Скачать руководство пользователя страница 5

           

Embedded  Solutions  

          Page  5

 

 

PMC-UNIV-TEST-ENG has some modifications when compared with the standard 
version.   The B side PMC type connectors are added, the SCSI is removed, and the 
testpoints are moved to the opposite side.  In this configuation the PMC side connectors 
can be installed into the host board, and the PMC can be installed into the carrier 
connectors on the A side [now facing up].  The testpoints are now on the A side to make 
them more convenient and provide a method of probing the PCI bus while the PMC is 
installed into the carrier via PMC-UNIV-TEST-ENG. 

  “B” Front side with the PMC type connectors – “plugs into 

host” 
 

“A” Rear side with carrier type connectors to mate to PMC. 

Note headers are this side for the –ENG configuration as it will be up to mate with the 
PMC. The headers will be away from the PMC   A secondary riser may be required with 
cPCI etc depending on how low the PMC connectors are located to the bottom edge of 
the carrier. 
    

Special features

• Passive 32 bit Universal voltage design 
• Bipass capacitors on all PMC power pins plus 10 uF on 5V and 3.3V. 
• JTAG header routed to PMC connections 
• PCI test points – easy to read staggered Silk labels both sides 
• 8 grounds to support logic analyzer connection as well as ocilloscope  
• User IO [Pn4] available through SCSI connector on standard model. 
 

Содержание PMC-UNIV-TEST

Страница 1: ...Suite C Santa Cruz CA 95060 831 457 8891 Fax 831 457 4793 http www dyneng com sales dyneng com Est 1988 User Manual PMC UNIV TEST PMC UNIV TEST ENG Revision A1 Revised 9 24 18 Corresponding Hardware R...

Страница 2: ...the product described in this document at any time and without notice Furthermore Dynamic Engineering assumes no liability arising out of the application or use of the device described herein The ele...

Страница 3: ...IO Interface Pin Assignment 7 Construction and Reliability 8 Thermal Considerations 8 WARRANTY AND REPAIR 9 Service Policy 9 Out of Warranty Repairs 9 For Service Contact 9 SPECIFICATIONS 10 ORDER INF...

Страница 4: ...n a PCI position the B side is forward the A side is the rear PMC UNIV TEST has the Host carrier side connectors mounted to the A side The PMC will have it s main component side forward in this config...

Страница 5: ...UNIV TEST ENG B Front side with the PMC type connectors plugs into host A Rear side with carrier type connectors to mate to PMC Note headers are this side for the ENG configuration as it will be up to...

Страница 6: ...Some names are truncated to allow larger easier to read print JTAG TRST TDI TDO TMST TCK plus a 3 3V and a Ground reference to interface with the installed PMC via the JTAG signals GND 8 Ground testpo...

Страница 7: ...0 9 10 5 6 11 12 41 42 13 14 7 8 15 16 43 44 17 18 9 10 19 20 45 46 21 22 11 12 23 24 47 48 25 26 13 14 27 28 49 50 29 30 15 16 31 32 51 52 33 34 17 18 35 36 53 54 37 38 19 20 39 40 55 56 41 42 21 22...

Страница 8: ...tion the connectors will last longer and jambing on will result in a shorter lifespan The PMC Module is secured against the carrier with the PMC connectors It is recommended for enhanced security that...

Страница 9: ...st accompany the return Dynamic Engineering will not be responsible for damages due to improper packaging of returned items For service on Dynamic Engineering Products not purchased directly from Dyna...

Страница 10: ...ates as PCI signals are matched and controlled Software Interface Passive no SW required for adapter Testpoints PCI signals plus JTAG and grounds Interface PMC front bezel directly rear IO via SCSI co...

Страница 11: ...ted to Pn4 for rear IO applications ROHS ROHS compliant parts and process ENG add second connector set remove SCSI switch headers to A side http www dyneng com PMC UNIV TEST html HDEterm68 http www dy...

Отзывы: