                Page  3

Table of Contents

PRODUCT DESCRIPTION

5

Headers and TestPoints

6

DipSwitch Settings

7

Options

7

XMC Module Backplane IO Interface Pin Assignment

9

APPLICATIONS GUIDE

10

Interfacing

10

Construction and Reliability

11

Thermal Considerations

11

WARRANTY AND REPAIR

12

Service Policy

12

Out of Warranty Repairs

12

For Service Contact:

12

SPECIFICATIONS

13

ORDER INFORMATION

14

Содержание PCIe 8L XMC X1

Страница 1: ...te C Santa Cruz CA 95060 831 457 8891 Fax 831 457 4793 http www dyneng com sales dyneng com Est 1988 User Manual PCIe 8L XMC X1 PCIe 8 Lane XMC Compatible Carrier Revision A2 Corresponding Hardware Re...

Страница 2: ...d in this document at any time and without notice Furthermore Dynamic Engineering assumes no liability arising out of the application or use of the device described herein The electronic equipment des...

Страница 3: ...h Settings 7 Options 7 XMC Module Backplane IO Interface Pin Assignment 9 APPLICATIONS GUIDE 10 Interfacing 10 Construction and Reliability 11 Thermal Considerations 11 WARRANTY AND REPAIR 12 Service...

Страница 4: ...Embedded Solutions Page 4 List of Figures FIGURE 1 PCIE8LXMCX1 PN4 INTERFACE STANDARD 9...

Страница 5: ...age monitors each with LED s on plus 12V minus 12V plus 5V plus 3 3V 10A regulator for XMC 3 3V and 5V supplies Selection switch for VPWR 12V or 5V Option for hardwired 5V or 12V Front panel connector...

Страница 6: ...der pwr used to connect to the XMC 025 sq post header The pin definitions are in the silk 1 3 3V 2 GND 1 TMS 2 TDO 3 TDI 4 TCK 5 TRST J2 controls the voltage on 33 67 of P2 when the SCSI connector opt...

Страница 7: ...X1 features cooling cutouts designed to support the addition of a fan in one or two positions for each XMC On PrXMC s and other XMC s with high thermal loads the fan option is a good idea On cards wit...

Страница 8: ...pad in the photo is A1 The mating part number is 120 964 455 Panduit DIN IDCA 64CSB TG30 Robinson Nugent Berg also has a part which is slightly taller Cables and breakouts are available from Dynamic...

Страница 9: ...16 14 A9 C9 9 43 19 17 A10 C10 10 44 20 18 A11 C11 11 45 23 21 A12 C12 12 46 24 22 A13 C13 13 47 27 25 A14 C14 14 48 28 26 A15 C15 15 49 31 29 A16 C16 16 50 32 30 A17 C17 17 51 35 33 A18 C18 18 52 36...

Страница 10: ...ces found at boot up on a splash screen with the VendorID and CardId for the XMC installed and an interrupt level If the information is not available from the BIOS then a third party PCI device catalo...

Страница 11: ...ugh hole for the IO The XMC Module connectors are keyed and shrouded with Gold plated pins on both plugs and receptacles They are rated at 1 Amp per pin 100 insertion cycles minimum These connectors m...

Страница 12: ...urn Dynamic Engineering will not be responsible for damages due to improper packaging of returned items For service on Dynamic Engineering Products not purchased directly from Dynamic Engineering cont...

Страница 13: ...ed Gen1 and Gen2 Software Interface Passive no SW required for adapter Initialization switch selections for VPWR bezel grounding and cable options Interface XMC front bezel via PCIe bracket and User I...

Страница 14: ...8LXMCX1 html HDEterm68 http www dyneng com HDEterm68 html 68 pin SCSI II to 68 screw terminal converter with DIN rail mounting HDEcabl68 http www dyneng com HDEcabl68 html SCSI cables with latch block...

Отзывы: