PLEASE READ BEFORE ATTEMPTING INSTALLATIONS

3000/ 3000LC/ 2000 SERIES CIRCUIT BOARD DESCRIPTION

Refer to Page 2 & 3 for wiring and voltage instructions



Power

 Input 

and

Contr

ol

Fig "A, B & E"



Door

 

Status

Fig "D"



Dynastat

Fig "C"

L2 OPTION - FUNCTION

Requires Dynastat option to work.
Red = secure / Green = unsecure
Reversing plug direction changes
light indication.

ATS OPTION - WIRING

Indicator device, by others, 

illuminates / sounds 

when access cover is removed.

Contact Rating: SPDT @ 0.5A

DYNASTAT

CONNECTOR

TIME DELAY ADJ.

CW  

 

 to increase.

Range 1-80 seconds

see fi g. "E" 



  3000/2000 series mag lock accepts 12/24 VAC/DC



  Circuit board shown fully loaded, with every option

ATS

SWITCH

LED

3 Pin Plug

LOCK HOUSING

Wht

Wht

2  Pin  Plug

not  polarized

COIL CONNECTOR PLUG

The Coil Connector is not polarized 

and may go on in either direction.

Blk

Blk

Wht

Wht

4 Pin Plug

COIL PLUG RECEPTACLE

VOLTAGE SELECTION 
JUMPERS - 

See page 2

SECURE

TAMPER

POWER INPUT 

FOR ATS

OPTION

GRN

WHT

RED

COM.

NO

NC

1

DynaLock Corp. 

z

 705 Emmett Street 

z

 P.O. Box 2728 

z

 Bristol, CT 06011-2728 

z

 1-877-DYNALOCK 

z

 www.dynalock.com

Electromagnetic Locking Systems

Содержание 3000 Series

Страница 1: ...Rating SPDT 0 5A DYNASTAT CONNECTOR TIME DELAY ADJ CW to increase Range 1 80 seconds see fig E 3000 2000 series mag lock accepts 12 24 VAC DC Circuit board shown fully loaded with every option ATS SWITCH LED 3 Pin Plug LOCK HOUSING Wht Wht 2 Pin Plug not polarized COIL CONNECTOR PLUG The Coil Connector is not polarized and may go on in either direction Blk Blk Wht Wht 4 Pin Plug COIL PLUG RECEPTAC...

Страница 2: ...ICATORS NOT INCLUDED 12 24 VAC INPUT NORMALLY CLOSED STATION CONTROL S I E PUSHBUTTONS KEYSWITCHES ETC WIRE MULTIPLE CONTROLS IN SERIES AS SHOWN NORMALLY CLOSED STATION CONTROL S I E PUSHBUTTONS KEYSWITCHES ETC WIRE MULTIPLE CONTROLS IN SERIES AS SHOWN FIG D 3000 2000 DYNASTAT OPTION 3000 2000 DSM OPTION DOOR SECURE DOOR UNSECURE NOTES 1 DYNASTAT CONTACTS RATED 1A MAXIMUM 2 INDICATORS NOT INCLUDED...

Страница 3: ... installation 2 For additional system wiring information refer to the installation documentation furnished with the external hardware and or peripheral devices I E power supply station controls keypad card readers etc supplied by DynaLock and or others 3000 2000 TD OPTION TIME DELAY 12 24 VAC VDC INPUT NORMALLY CLOSED STATION CONTROL S I E PUSHBUTTONS KEYSWITCHES ETC WIRE MULTIPLE CONTROLS IN SERI...

Страница 4: ...L CONTACT BETWEEN THE MATING SURFACE OF THE LOCK AND ARMATURE MAGNET OVERHEATS LOCK SET FOR 12V WITH VERIFY THAT JUMPERS MATCH AND OR DRAWS EXCESS 24V APPLIED INPUT VOLTAGE SEE TOP OF PAGE 2 CURRENT POSSIBLE SHORTED COIL PERFORM THE COIL RESISTANCE CHECK REFER TO BOTTOM OF PAGE 3 DYNASTAT BOND SENSOR INSUFFICIENT SUPPLY VOLTAGE CHECK SUPPLY FOR PROPER INPUT NOT INDICATING DOOR VOLTAGE SHOULD BE WI...

Страница 5: ...ngle models and 0 32 Amps for double models Damage may occur if input voltage exceeds 16V AC DC Do not attempt operation at higher voltages GENERAL INFORMATION BASIC INPUT POWER WIRING 3000 2000 x LP BASIC 12 VDC INPUT 12VDC INPUT FIG A NORMALLY CLOSED STATION CONTROL S I E PUSHBUTTONS KEYSWITCHS ETC WIRE MULTIPLE CONTROLS IN SERIES AS SHOWN 1 2 3 4 5 6 7 8 9 10 3000 2000 x LP BASIC 12 VAC INPUT 1...

Страница 6: ...ION NOTE TO PROTECT OTHER ELECTRONIC DEVICES IN SYSTEM CONNECT THE SUPPLIED MOV ACROSS THE LEADS AS SHOWN ABOVE NOTE TO PROTECT OTHER ELECTRONIC DEVICES IN SYSTEM CONNECT THE SUPPLIED MOV ACROSS THE LEADS AS SHOWN ABOVE JUMPER WIRING INSTRUCTIONS DynaLock 705 Emmett Street Bristol CT 06011 2728 Phone 860 582 4761 Fax 860 585 0338 SERIES 2000 3000 x LCB ELECTROMAGNETIC LOCK ...

Отзывы: