Configuration
Setting the CAN address
The CAN address of the device is set using the two address selector switches HIGH and LOW.
Addresses 1 to 250 (01 hex to FA hex) can be used in a CAN network. The address is set using
the hexadecimal numbering system. The LOW selector switch is for the low-order digit and the
HIGH selector switch is for the high-order digit.
Notice!
Each address may only occur once in the system, otherwise network conflicts will occur.
The address 0 (00 hex, set on delivery) ensures that the device is disconnected from the
remote communication. This means that the device does not appear in the system, even if it is
connected to the CAN bus.
HIGH
LOW
Address
0
0
Stand-alone
0
1 to F
1 to 15
1
0 to F
16 to 31
2
0 to F
32 to 47
3
0 to F
48 to 63
4
0 to F
64 to 79
5
0 to F
80 to 95
6
0 to F
96 to 111
7
0 to F
112 to 127
8
0 to F
128 to 143
9
0 to F
144 to 159
A
0 to F
160 to 175
B
0 to F
176 to 191
C
0 to F
192 to 207
D
0 to F
208 to 223
E
0 to F
224 to 239
7
7.1
24
en | Configuration
Promatrix 6000 Router
18-Jun-2015 | 03 | F01U306895
Operation manual