MAINS OPERATION & RESULTING POWER AMP TEMPERATURES
The following tables are useful in determining power supply and cabling requirements.
The power drawn from the mains network is converted into acoustic output to feed the connected
loudspeaker systems plus heat. The difference between drawn power and dispensed power is referred
to as leakage power or dissipation (
P
d
). The amount of heat resulting from power dissipation might
remain inside of a rack-shelf and needs to be diverted using appropriate measures. The following table
is meant as auxiliary means for calculating temperatures inside of rack-shelf systems/cabinets and the
ventilation efforts necessary.
The column “Pd” lists the leakage power in relation to different operational states. The column “BTU/
hr” shows the
dispensed heat amount per hour
.
MAINS OPERATION & RESULTING TEMPERATURES
Xa 4000
Umains
[V]
Imains
[A]
Pmains
[W]
Pout
SUB+TOP
[W]
Pd (5)
[W]
BTU/hr(1)
idle
230V
1
80
-
80
273
Max. Output Power @ 8
Ω
(
1)
230V
10,6
1640
600+500
540
1840
Max. Output Power @ 4
Ω
(
1)
230V
18,2
3000
1100+900
1000
3410
1/3 Max. Output Power @ 4
Ω
(
1)
230V
10,3
1580
366+300
914
3120
1/8 Max. Output Power @ 4
Ω
(
1)
230V
4,5
610
137+113
360
1230
1/8 Max. Output Power @ 4
Ω
(
2)
230V
5,5
790
137+113
540
1840
1/8 Max. Output Power @ 4
Ω
(
2), (4)
254V
5,5
840
166+137
537
1830
Normal Mode (-10dB) @ 4
Ω
(
1)
230V
4,1
550
110+90
350
1190
Rated Output Power (0dB) @ 4
Ω
(
1)
230V
17,2
2800
1000+800
1000
3410
Alert (Alarm) Mode (-3dB) @ 4
Ω
(
1)
230V
12,3
1920
500+400
1020
3480
1/3 Max. Output Power @ 2
Ω
(
2)
230V
16,7
2720
600+533
1587
5420
1/8 Max. Output Power @ 2
Ω
(
1)
230V
7,2
1050
225+200
625
2130
1/8 Max. Output Power @ 2
Ω
(
2)
230V
8,8
1260
225+200
835
2850
(1) Sine Signal Modulation (80Hz/1kHz)
(2) Band-limited Pink Noise
(3) 1BTU = 1055.06J = 1055.06Ws
(4) 10% Mains Over Voltage
(5) Pd = Leakage Power
The following factors allow direct proportional calculation of the power consumption for different mains
supply voltages:
100V = 2.3; 120V = 1.9; 220V = 1.05; 240V = 0.96
9
Содержание Amp Xa 4000
Страница 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI...
Страница 14: ......
Страница 15: ...BEDIENUNGSANLEITUNG...
Страница 28: ...28...
Страница 29: ...MODE D EMPLOI...
Страница 43: ...BLOCK DIAGRAM 43...
Страница 44: ...DIMENSIONS 44...
Страница 45: ...NOTES 45...
Страница 46: ...NOTES 46...
Страница 47: ...NOTES 47...