Dyna-Glo BF10DTDG-2 Скачать руководство пользователя страница 4

3

IMPORTANT:

 Read this owner’s manual carefully and completely before trying to assemble, operate, 

or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, 

explosion, electrical shock, and carbon monoxide poisoning.

IMPORTANT SAFETY INFORMATION 

 

 

Installation and repair should be done by a qualified service person. The appliance should be 

inspected before use and at least annually by a professional service person. More frequent 

cleaning may be required due to excessive lint from carpeting, bedding material, etc. It 

is imperative that control compartments, burners and circulating air passageways of the 

appliance be kept clean.

 

 

WARNING:

 Any change to this heater or its controls can be dangerous. 

 

WARNING:

 

Carefully supervise young children when they are in the room with the heater.

 

WARNING: 

Heater becomes very hot when operating. Children and adults should be alerted 

       to the hazard of high surface temperatures and should stay away to avoid burns or clothing 

       ignition Heater will remain hot for a time after shutoff. Allow surfaces to cool before touching. 

 

 

WARNING:

 Make sure any panel, safety screen or guard removed for servicing an appliance   

       is replaced prior to operating the heater
 

WARNING:

 Keep the appliance area clear and free from combustible materials, gasoline, and  

 

other flammable vapors and liquids. 

 

WARNING:

 Do not place clothing or other flammable material on or near the appliance. Never  

 

place any objects on the heater.

       

WARNING:

 Due to high temperatures, locate this appliance out of traffic and away from

       furniture and draperies.
This appliance is intended for supplemental heating.

This appliance can be used with propane or natural gas. It is shipped from the factory adjusted for 

use with propane.

CARBON MONOXIDE POISONING: 

Early signs of carbon monoxide poisoning resemble the flu with 

headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get 

fresh air immediately! Have heater serviced. Some people are more affected by carbon monoxide than 

others. These include pregnant women, people with heart or lung disease, people who are 

anemic, those under the influence of alcohol, and those living in high altitudes.

NATURAL AND PROPANE/LP GAS:

 Natural and Propane/LP gases are odorless. An odor-making 

agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas 

can fade. Gas may be present even though no odor exists. Make certain you read and understand all 

warnings. Keep this manual for reference. It is your guide to operating this heater safely. 

If the heater is being installed in a residential garage, it must be secured firmly to the 

wall, a minimum of 18 in. (457mm) above the floor. The heater must be located so that it 

is protected against any possibility of damage by a moving vehicle, etc.

Raising the heater will reduce BUT NOT eliminate the possibility of lighting the vapor of any

flammable liquids which may be improperly stored or accidentally spilled. If the smell of 

gasoline is present, do not operate this heater until the area has been properly ventilated.

WARNING:

Содержание BF10DTDG-2

Страница 1: ...d Refer to Air For Combustion and Ventilation section on page 8 of this manual This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with propane or natural gas This appliance is equipped with a simple means to switch between propane and natural gas Field conversion by any other means includ...

Страница 2: ......

Страница 3: ...Fuel Type Natural Gas Propane Natural Gas Propane Ignition Electronic Push Button Electronic Push Button Manifold Pressure 5 in W C 10 in W C 5 in W C 10 in W C Inlet Gas Pressure Maximum 14 in W C 14 in W C 14 in W C 14 in W C Mínimum For purposes of input adjustment 6 in W C 11 in W C 6 in W C 11 in W C Dimensiones in H x W x D 20 00 in x 17 32 in x 9 49 in 242 0 in x 20 94 in X 10 08 in Fan Rat...

Страница 4: ...objects on the heater WARNING Due to high temperatures locate this appliance out of traffic and away from furniture and draperies This appliance is intended for supplemental heating This appliance can be used with propane or natural gas It is shipped from the factory adjusted for use with propane CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning resemble the flu with headaches diz...

Страница 5: ...ors from these products may create a white powder residue within burner box or on adjacent walls or furniture 8 Do not use heater if any part has been under water Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water 9 Turn off and unplug heater and let cool before servicing Only a qua...

Страница 6: ...ODELS The fan kit helps to distribute the warmed air into the space more rapidly NOTE This is an optional accessory and is not required for operation of the heater State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a c...

Страница 7: ...pproximately one 1 ounce 30 mL of water for every 1 000 BTUs 3 Kw of gas input per hour An unvented room heater is intended as a supplemental heater rather than a primary heat source In most supplemental heat applications the water vapor does not create a problem In most applications the water vapor enhances the low humidity atmosphere experienced during cold weather The following steps will help ...

Страница 8: ...e unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are connecting only if there are doorless passageways or ventilation grills between them Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combusti...

Страница 9: ...BTU hr Example Gas heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum BTU hr the space can support with the actual amount of BTU hr used _______ BTU h...

Страница 10: ...ems directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activa...

Страница 11: ...he support legs Select models WARNING Maintain the minimum clearances shown in See Fig 3 If you can provide greater clearances from floor ceiling and joining wall Fig 3 Mounting clearances as viewed from front of heater inches A second side wall must be at least 18 in away from the other side of the heater Always maintain a minimum of 36 in clearance from furniture and draperies For the installati...

Страница 12: ...ocked positions 3 Remove plug from the inlet of the NG regulator 4 If the LP plug was removed previously apply thread sealant to ensure that there are no leaks and install the NG plug into the inlet of the LP regulator and tighten firmly See Fig 5a and 5b 5 Replace selector valve access panel NG TO LP CONVERSION 1 Before gas conversion remove screws and access panel for selector valve 2 The gas se...

Страница 13: ...panel using a screwdriver See Fig 9 Attach Fan to the rear panel of the heater using the four screws provided NOTE Be sure the rocker switch is positioned in the upper right corner See Fig 10 3 This fan is equipped with manual MAN and automatic AUTO settings See Fig 11 on page 13 Set the rocker switch to MAN for manual mode allowing the fan to continuously run until the rocker switch is returned t...

Страница 14: ...Screws M4 15 1 Set down a blanket onto the table where the heater will be placed for leg installation to prevent scratch ing of the table and or the heater 2 Set back of heater on table with the bottom of heater extending outside the table edge 3 Fasten Support Legs to heater using Support Leg Screws Fig 13 Note If the heater is to be installed directly on carpet ing tile or other combustible mate...

Страница 15: ... mounting bracket to wall where heater will be located Make sure mounting bracket is level 2 Mark screw locations on wall See Fig 16 Note Mark only last hole on each end of mounting bracket Insert 2 wood screws ST 8 45 16 total through these holes only 3 Remove tape and mounting bracket from wall Attaching Mounting Bracket To Wall Note Expansion bracket wood screws ST 8 45 16 and wall hanging spac...

Страница 16: ...hole on each end of bracket with expansion bracket 6 Insert expansion bracket screws ST4 8 15 16 through wall mounting bracket and into expansion brackets 7 Tighten expansion bracket screws ST4 8 15 16 until mounting bracket is firmly fastened to wall 8 Check that the bracket is secure before mounting heater Attaching Wall Hanging Spacers to Heater WARNING Failure to properly install the wall hang...

Страница 17: ...must be a minimum 6 WC for NG 11 WC for LP with a max pressure of 14 WC for NG 14 WC for LP If gas line pressure is higher regulator damage could occur CAUTION Never connect heater directly to an LP supply This heater requires an external regulator not supplied Install the external regulator between the heater and gas supply CAUTION Avoid damage to regulator Hold gas regulator with wrench when con...

Страница 18: ...G 3 5kPa The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa Pressure Testing Gas Supply Equal To or less than 1 2 PSIG 3 5kPa The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing of t...

Страница 19: ... service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS MANUAL GAS CONTROL 1 STOP Read the safety information above on this page 2 Turn off all electric power to the appliance 3 Push in gas control knob slightly and turn clockwise to OFF position See Fig 22a NOTE Knob cannot be turned from PILOT...

Страница 20: ...gnitor button until the pilot lights The pilot is visible centered below the main burner behind the glass panel See Fig 24 7 Keep control depressed for 30 seconds after pilot lights Release control knob Note If pilot goes out repeat steps 3 through 7 Wait 1 minute before attempting to light pilot again If after several tries the pilot still goes out turn the gas control knob clockwise to the OFF p...

Страница 21: ...OPERATION Manual valves remain burning at the desired setting until manually turned to OFF See Fig 25 Fig 25 Control Knob Position Manual Thermostatic OPERATION INSPECTING BURNERS Check pilot flame pattern daily when in use and at least yearly by a qualified service agency PILOT FLAME PATTERN Fig 26 shows a correct pilot flame pattern Fig 27 shows an incorrect pilot flame pattern The incorrect pil...

Страница 22: ... tern with tall flames with Control Knob Set to High Flame 5 1 2 Glass Height 1 2 Glass Height NOTE Ambient flame burners produce both a blue and yellow flame An excessively high yellow colored flame may be caused by airborne dust dander pet hair etc Additionally an excess amount of Mercaptane in the fuel can result in an orange or yellow colored flame The upper third of flame may be bright yellow...

Страница 23: ...don t follow directions on the can you could damage the pilot assembly CAUTION Never use a wire needle or similar object to clean ODS pilot This can damage ODS pilot unit 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Remove 4 screws 2 screws on each side of the front panel 3 Pull front panel forward 4 Blow air through the ports slots and holes in the ...

Страница 24: ...ectrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad ignitor module or ignition module 1 Replace ODS 2 Replace ODS 3 Replace ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Replace ignitor cable 6 Replace ignitor module or ignition module Unit shuts off after running a few minutes 1 Gas supply is tur...

Страница 25: ...1 Not enough air 2 Gas regulator is defective 3 Wrong gas type selected 1 Check burner for dirt and debris If found clean burner see Care and Maintenance page 21 2 Replace gas regulator 3 See Gas Selection page 11 Gas odor during combustion 1 Foreign matter between control valve and burner 2 Gas leak See Warning Statement at top of page 23 1 Take apart gas tubing and remove foreign matter 2 Locate...

Страница 26: ...er 3 Clean ODS pilot see Care and Maintenance page 22 Gas odor exists even when control knob is in OFF position 1 Gas leak See Warning Statement at top of page 22 2 Control valve is defective 1 Locate and correct all leaks see Checking Gas Connections page 17 2 Contact customer service Moisture condensation noticed on windows 1 Not enough combustion ventilation air 1 Refer to Air for Combustion an...

Страница 27: ... TROUBLESHOOTING QUALIFIED INSTALLING AGENCY Only a qualified agency should perform installation and replacement of gas piping gas utilization equipment or accessories and repair and servicing of equipment The term qualified agency means any individual firm corporation or company that either in person or through a representative is engaged in and is responsible for a Installing testing or replacin...

Страница 28: ...560 0630560 0630560 7 Manual Gas Valve 1 GS7A 10K GS7A 20K GS7A 30K GS7A 30K 8 Gas Selector Valve 1 GH01A 10K GH01A GH01A GH01A 9 Regulator Bracket 1 AQ000015 AQ000015 AQ000015 AQ000015 10 1 Regulator LP Propane 10 WC 1 GR 130A 10K GR 130A 20K GR 130A 30K GR 130A 30K 10 2 Regulator NG Natural Gas 5 WC 1 GR 130 10K GR 130 20K GR 130 30K GR 130 30K 11 Glass Panel 1 AQ000164 AQ000148 AQ000180 AQ00018...

Страница 29: ...__________________________________________ TYPE OF STORE __________________________ CITY STATE WHERE PURCHASED ______________________________________________ PRICE PAID _______________________ Please Take a Minute To Give Us Your Answers To The Following Questions All Responses Are Used Solely For Market Research And Are Held In Strict Confidence Who primarily decided this purchase Male Female 18 ...

Страница 30: ...rds SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 8280 Austin Avenue Morton Grove IL 6 0 0 5 3 3 2 0 7 Tel 847 324 5900 Fax 847 324 5901 Toll Free 877 GHP Group 8 7 7 4 4 7 4 7 6 8 www ghpgroupinc com GHP GHP Group Inc 6440 W Howard St Niles IL 60714 3...

Отзывы: