WORKING PRINCIPLES 

 
The Nightstar ULV/LVM is a combination Ultra-Low-Volume/Low-Volume-Mister aerosol 
applicator.  It is electrically powered by either 115 volts or 230 volts AC.  The machine is 
available in (3) different models: 
 
1) 

NIGHTSTAR M

... Mounted on a heavy duty, welded steel frame with large wheels for 

transporting.  The  fan  housing  and  nozzle  has  a  vertical,  horizontal,  upward/downward 
adjustment capability. 
 
2) 

NIGHTSTAR  S

...  Mounted  on  a  universal  swivel  bracket,  the  entire  unit  can  be 

mounted from  the  ceiling  and  swiveled  3  60 degrees for optimum positioning. The fan 
housing and nozzle can be adjusted upward and downward. 
 
3) 

NIGHTSTAR T

... Mounted on a compact, heavy duty welded-steel frame with low 

profile, rubber mounting feet. Designed to be mounted stationary on a table top or 
platform type surface.  The fan housing and nozzle have horizontal and upward and 
downward adjustment capability. 
 
All models operate on the same principles: 
 
Air for the liquid spray is created by a 2-stage, high RPM electric motor/blower.  Air from 
the  blower  pressurizes  the formulation  and flush  tanks, and  supplies  air  thru a flexible 
hose  to  the  nozzle  for  atomizing  the  liquid.  The  air  that  is  supplied  to  the  formulation 
tank  is  accurately  regulated  by  means  of  an  air  bleed  orifice.    This  orifice  can  be 
changed to produce the desired flow rate. This flow rate is what determines the droplet 
size  being  produced  by  the  nozzle.    Therefore,  the  smaller  the  air  bleed  orifice  being 
used, the higher the tank pressure, the higher the flow rate, and the larger the droplet 
that will be produced. 
 
The spray circulation air is provided by a High Air Flow (8000 CFM, 226 Cu.m/min) axial 
fan.  The fan has been tested and proven to provide even droplet distribution in areas of 
up to 60,000 square feet (6000 square meters) without any additional fan assistance. 
 
To  adequately  dispense  two-part  formulations  that  tend  to  separate  over  time  (ie. 
wetable  powders),  the  NIGHTSTAR™  can  be  equipped  with  an  optional  auxiliary 
formulation agitation system.  The agitation system consists of two parts: 
1)  An  air  circulation  tube  that  provides  high  velocity  air  to  the  formulation  tank  for 
pressurization and agitation. 
2) An electric motor driven pump that circulates and mixes the formulation.  This pump 
is activated by pushing the auxiliary agitation switch to the "ON" position. 
 

After  a  spray  treatment  is  completed,  the  entire  spray  system  is  automatically 
flushed.  The agitation pump is then turned off and the fan and blower are turned 
off when their pre-programmed time expires. 

Содержание NIGHTSTAR 2985

Страница 1: ...1 P a g e DYNA FOG NIGHSTAR MANUAL MODEL 2985 SERIES 1 ULV LVM AEROSOL APPLICATOR MANUFACTURED BY CURTIS DYNA FOG Ltd 17335 U S Highway 31 North WESTFIELD INDIANA U S A www dynafog com...

Страница 2: ...TAR M MODEL 1901 115 V 60 MODEL 1902 230 V 50 60 1 NIGHTSTAR S MODEL 19 03 115 V 60 MODEL 1904 230 V 50 60 1 NIGHTSTAR T MODEL 19 05 115 V 60 MODEL 1906 230 V 50 60 1 United States Patent No 5 299 737...

Страница 3: ...17 Machine Position with without fan 18 Fluid System Diagram 19 Preventative Maintenance Schedule 20 Electrical Wiring Diagram 21 Troubleshooting Tips 22 Machine Assembly Diagram 23 24 Tank Assembly...

Страница 4: ...ant savings in labor costs chemical usage and invaluable health benefits Field trials have proven that droplets created with the NIGHTSTAR circulate entirely throughout areas as large as 60 000 square...

Страница 5: ...use poor performance and overheating of electrical components Extension cords that are underrated too small of wire or that are too long will cause a voltage drop NOTE Nightstar 115 Volt models requir...

Страница 6: ...7 5 95 3 WIDTH 31 5 78 7 HEIGHT 70 4 179 DOWN 80 6 205 UP M MOBILE WEIGHT LBS KG EMPTY 220 100 FULL 252 114 2 STAGE BLOWER 2 0 0 00 RPM 104 CFM NO LOAD 115 50 60 1 230 50 60 1 AXIAL WATER RESISTANT 22...

Страница 7: ...O MEMORY WATER RESISTANT LOCKABLE ENCLOSURE FAN ON OFF NOZZLE BLOWER SPRAY ON OFF 115 Volt 25 AMP FUSE 230 Volt 15 AMP FUSE 7 1 A 115V 3 6 A 230V 9 6 A 115V 7 0 A 230V 8 A 115V 4 A 230V 18 0 A 115V 11...

Страница 8: ...The air that is supplied to the formulation tank is accurately regulated by means of an air bleed orifice This orifice can be changed to produce the desired flow rate This flow rate is what determine...

Страница 9: ...emical Know any dangers of the solution used and what to do in case of an accident involving the solution The NIGHTSTAR is designed to create an equal number of uniform droplets at each flow rate sele...

Страница 10: ...ULATION FAN IS OPERATING WHEN DOING A SPRAY TREATMENT To measure the flow rate 1 Fill the formulation tank with water 2 Weigh the tank 3 Replace tank cap and HAND TIGHTEN TO SEAL 4 Allow unit to spray...

Страница 11: ...se as much chemical as would have been applied by conventional High Volume Spraying Example To apply a product labeled for use at 8 fl oz in 100 US gallons 40 000 square feet 1 acre 50 ml per 100 1 to...

Страница 12: ...ON IN THE TANK THAT IS NECESSARY TO DO ONE APPLICATION Tighten the plastic cap to seal the tank If you have the optional auxiliary agitation system tighten the knurled brass couplings on the circulati...

Страница 13: ...contents of the flush tank When the tank is full this time should be approximately 5 minutes D Post Air Circulation Time Post Air Circulation Time is the time per for circulating the spray droplets af...

Страница 14: ...HUWLQJ KXEV LQWR HQFORVXUH FDUHIXOO WLJKWHQ KXE ORFN QXW R QRW RYHU WRUTXH 5HSODFH SULQWHG FLUFXLW ERDUG PDNLQJ VXUH WR HQJDJH VSULQJ ODWFK DW WKH ERW 7 WRP RI 3 LUH LQ DFFRUGDQFH ZLWK QDWLRQDO DQG OR...

Страница 15: ...5 QFORVXUH IRU QGRRU RU 2XWGRRU QVWDOODWLRQ HOORZ DQG UHHQ LJKWV QGLFDWH 3RZHU DQG 6WDWXV 63 56 8 33 7 21 7KH 0 9 6HULHV 7LPH RQWUROV DUH XQLYHUVDO HOHFWURQLF WLPH VZLWFKHV GHVLJQHG IRU JHQHUDO SXUSRV...

Страница 16: ...O 2 NC 2 NO NC L 2 N L 1 T TIMER L N 120VAC COM LOAD J1 COM2 NO 2 NC 2 NO NC L 2 N L 1 T TIMER L1 L2 240VAC COM LOAD 1 J1 J2 NO 2 NC 2 NO NC L 2 N L 1 T TIMER L N 120VAC COM LOAD 1 LOAD 2 J1 J2 COM2 N...

Страница 17: ...UDQW LV H WHQGHG WR WKH RULJLQDO SXUFKDVHU RQO DQG LV QRW WUDQVIHUDEOH 7KLV ZDUUDQW GRHV QRW DSSO WR D GDPDJH WR XQLWV FDXVHG E DFFLGHQW GURSSLQJ RU DEXVH LQ KDQGOLQJ DFWV RI RG RU DQ QHJOLJHQW XVH E...

Страница 18: ...18 P a g e RECOMMENDED MACHINE POSITION WITHOUT AUXILIARY FAN S RECOMMENDED AUXILIARY FAN POSITION...

Страница 19: ...19 P a g e...

Страница 20: ...UARD CLEAN BLOWER AIR INTAKE FILTER CLEAN 3 WAY SOLENOID VALVE CLEAN FORMULATION TANK FILTER CLEAN PUMP INTAKE FILTER OPTIONAL INSPECT AIR BLEED HOLE IN FORM CAP NOTE THESE INTERVALS REPRESENT AN APPR...

Страница 21: ...21 P a g e...

Страница 22: ...FLUID LINE TIGHTEN ALL FLUID TUBE FITTINGS CHECK TUBING FOR CUTS 4 BLOWER OR FAN DOES NOT RUN AT STEADY SPEED 3 WAY VALVE CHATTERS MACHINE IS WIRED TO AN INADEQUATE POWER SUPPLY CHECK VOLTAGE AT PLUG...

Страница 23: ...23 P a g e...

Страница 24: ...64516 DESCRIPTION LOCKING HANDLE FEMALE GUARD NOZZLE MOUNTING SCREW NOZZLE AY NIGHTSTAR ELBOW AY OUTPUT SPACER GUARD FAN BLADE AY MOTOR 115V MOTOR 230V HOUSING FAN SCREW GUARD INLET BEARING PIVOT SCR...

Страница 25: ...25 P a g e...

Страница 26: ...26 P a g e...

Страница 27: ...27 P a g e...

Страница 28: ...TCH 2 POSITION 11 64167 FLUSH HOLDER 12 64544 FUSE 115V 25 AMP 64545 FUSE 230V 15 AMP 13 64199 SWITCH NORM OFF MOMEN 14 64199 1 BOOT SWITCH PUSHBUTTON 15 64117 TOP COVER HOUSING 16 64131 HOUSING AY CO...

Страница 29: ...LTIPLY BY MILLIMETERS INCHES 03937 CENTIMETERS INCHES 3937 METERS FEET 3 281 SQUARE METERS SQUARE FEET 10 764 SQUARE METERS ACRES 000247 CUBIC METERS CUBIC FEET 35 31 GRAMS OUNCES FLUID 035 MILLILITER...

Страница 30: ...30 P a g e...

Страница 31: ...31 P a g e CAP INSERT AY P N 64593...

Страница 32: ...32 P a g e...

Страница 33: ...s type pump is allowed to run against a closed valve the internal bypass will automatically recirculate the flow within the pump at the preset bypass pressure Caution The standard series pump is not e...

Страница 34: ...ET 2100 SERIES SERVICE PARTS KIT LIST Typical 2100 Series Assembly PARTS KIT DESCRIPTION IT IS RECOMMENDED THAT THE PUMP BE THOROUGHLY FLUSHED WITH WATER OR OTHER NEUTRALIZING AGENT AFTER EACH USE WHE...

Страница 35: ...th a Flow Control restriction orifice Location of the Flow Control Orifice The machine is including two different sizes of Flow control orifices as following Orifice 19 produces a Flow Rate of 140 ml...

Страница 36: ...36 P a g e...

Страница 37: ...37 P a g e...

Страница 38: ...s with 1 3 gallon tanks available in 115 and 230 VAC COMBUSTION ENGINE DRIVEN ULV AEROSOL GENERATORS Truck mounted Units powered by 8 9 11 18 and 20 HP four cycle OHV Gasoline Engines Diesel versions...

Отзывы: