SPECIFICATIONS 

 
The  Cyclone™  Ultra  machine  is  an  electric  “Cold  Fog”  ULV  that  utilizes  a  rugged 
anodized aluminum nozzle and a high performance blower. 
  
 This  device  is  intended  for  applications  of  both  Oil  Based  (following  necessary 
precautions) and Water Based chemical treatments. 
  
The  body  and tank  are  made  of high-density  chemical  resistant  polyethylene.  The 
applicator is useful for dispensing most chemicals which are labeled for aerosol or 
mist applications such a disinfectants, deodorizers, germicides, insecticides, etc., in 
locations  such  hospitals,  schools,  nursing  homes,  greenhouses,  stables, 
warehouses, homes, and farm buildings. The particle sizes generated range from 7 
to  30  microns  VMD,  obtained  using  water.  Machine  output  and  particle  size  are 
dependent upon the viscosity of the liquid being dispensed.  

 

Cyclone™ Ultra model 2734, 110-130 VAC 

Cyclone™

 

Ultra model 2736, 210-250 VAC 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
This  machine  is  one  of  the  world’s  finest  hand  held  ULV/Mist  generator  built  to 
precision  standards.  With  reasonable  care  and  maintenance,  this  efficient 
equipment  will  provide  many  hours  of  service.  For  best  result,  this  ULV  generator 
must be operated and maintained in compliance with these instructions. 
 
 
 

 

MOTORIZED BLOWER: 

 

MODEL 2734 

MODEL 2736 

Continuous Duty 
110-130 VOLTS AC 
6.85 AMPS 
50/60 HZ 
20,000 RPM 
107 CFM (6.42 m

3

/min) Max 

Continuous Duty 
210-250 VOLTS AC 
3.4 AMPS 
50/60 HZ 
22,000 RPM 
109 CFM (6.54 m

3

/min) Max 

Содержание CYCLONE ULTRA 2734

Страница 1: ...1 P a g e DYNA FOG CYCLONE ULTRA Ultra Low Volume Sprayer MODEL 2734 2736 OPERATION AND MAINTENANCE MANUAL TM...

Страница 2: ...IAGRAM 8 MAJOR COMPONENTS DIAGRAM 9 GENERAL DIMENSIONS 10 HOUSING ORIENTATION 10 FLOW RATE 11 MAINTENANCE 12 ELECTRICAL SCHEMATIC 13 ROTARY FAN REPLACEMENT 14 SPARE PARTS FOR THE MOTOR 15 EXPLODED DIA...

Страница 3: ...ne and the marked rating of the extension cord A single extension cord only should be used When two or more extension cord are placed in series the rated current carrying capacities of the cords may n...

Страница 4: ...inguishing all pilot lights and turning off all unnecessary electric power To avoid danger of fire or explosion in an enclosed space the enclosed volume fogging time and required formulation volume sh...

Страница 5: ...ng parts Do not Restrict the motor blower inlet area Do not Tamper with the output nozzle Do not Allow the machine to operate unattended Do not Apply more than one gallon of formulation per 50 000 cub...

Страница 6: ...rehouses homes and farm buildings The particle sizes generated range from 7 to 30 microns VMD obtained using water Machine output and particle size are dependent upon the viscosity of the liquid being...

Страница 7: ...the atmosphere The liquid is delivered to the liquid spout by a combination of positive and negative pressures A negative pressure is generated in the nozzle by the exiting air mass and a positive pr...

Страница 8: ...8 P a g e FLUID SYSTEM DIAGRAM Cyclone Ultra...

Страница 9: ...9 P a g e MAJOR COMPONENTS DIAGRAM Cyclone Ultra...

Страница 10: ...10 P a g e GENERAL DIMENSIONS...

Страница 11: ...ormulatio n Droplet Size Microns LOW 40 ML MIN 1 4 OZ MIN 8 VMD 37 ML MIN 15 VMD 12 ML MIN 0 4 OZ MIN 20 VMD MED 83 ML MIN 2 8 OZ MIN 10 VMD 80 ML MIN 2 7 OZ MIN 18 VMD 48 ML MIN 1 6 OZ MIN 22 VMD MAX...

Страница 12: ...er Assembly 4 If it becomes necessary to disassemble the Machine Flow Valve for cleaning be careful not to enlarge the metering orifice or damage the taper of the valve steam as this will affect the c...

Страница 13: ...13 P a g e ELECTRICAL SCHEMATICS...

Страница 14: ...rated without air intake filter or if disinfectant is applied in a closed room The Fresh Air Intake hose P N 62060 is recommended for those kinds of applications When the machine is disconnected from...

Страница 15: ...the nut onto the shaft thread SPARE PARTS FOR THE MOTOR ITEM QTY P N DESCRIPTION VOLTAGE 1 1 39651 5 Rotary Fan 4 93 O D 110 130 VAC BLOWER 120 VAC SERVICE KIT P N 63534 2 1 39651 5 Rotary Fan 4 93 O...

Страница 16: ...16 P a g e CYCLONE ULTRA EXPLODED DIAGRAM...

Страница 17: ...WER 115 V 1 62340 BLOWER 230 V 18 1 62002 1 HOUSING CLOSURE 19 1 62160 SCREW 10 16 x 1 25 SHWH 20 5 62161 SCREW 10 16 x 75 THR 21 2 62309 2 MOTOR BRUSH 115 V 2 62340 1 MOTOR BRUSH 230 V 22 1 62366 GAS...

Страница 18: ...AY BRASS WITH FILTER ITEM QTY PART NUMBER DESCRIPTION 1 1 32692 1 NUT PACKING BRASS 2 1 32690 WASHER PACKING 3 1 32691 WASHER BRASS 4 1 62319 1 STEM VALVE 5 1 62180 VALVE BODY BARB AY 6 1 10100 110 O...

Страница 19: ...19 P a g e NOISE LEVEL COMPARISON CHART The Cyclone Ultra hand held electric aerosol applicator is a relatively quite machine as shown in above comparison...

Страница 20: ...20 P a g e REV 10 09 Rev 11 4 2013...

Отзывы: