Tridak® Model 1200 Filling System User Guide
Utilities Required
Air: 60-80 psi (0.41-0.55 MPa), 50 micron filtered, non-lubricated; dry air is required
Electric: 120 VAC, 50/60 Hz
Parts Included in Model1200 Syringe Filling System
■
Model 1200 Syringe Filling System (T17563)
■
Air Line Kit (T16789)
■
Fluid Line Kit, 3/8" OD Black Polyethylene Tubing (T16787)
■
Footswitch (T14999)
■
Power Cord, 110 VAC, 7 Ft. (T17021)
■
Printed User Manual (T17566)
Preparing the System for Use
WARNINGS & PRECAUTIONS!
The supply air MUST be connected before connecting air to reservoir! Disconnect the air to reservoirs
BEFORE supply air is disconnected! The Model 828 dispensing valve used in this system is normally
open.
Don’t start without a syringe in place!
Cartridge Retainer Preparation
1.
Install Cartridge End Fitting onto a Cartridge Retainer.
2.
Place a filled Cartridge into the Cartridge Retainer.
3.
Install and securely tighten the Cartridge Retainer Cover Assembly onto the Cartridge Retainer.
Figure 2.20 oz. Cartridge Retainer
Cartridge End Fitting
Cartridge Retainer
Cartridge Retainer Cover Assembly
Cartridge (Inside Cartridge Retainer)