Tridak® Model 1001 Syringe Filling System User Guide
Description of Main Components
The main components in the Model 1001 Syringe Filling System include:
1.
Air Regulator
–
The air regulator enables precise control of the air pressure in the fluid reservoir. The
air precision regulator includes:
a.
Pressure gauge that displays the pressure in the fluid reservoir. A 0- to 100-psi (0- to
6.9-bar) pressure gauge is installed on the air regulator.
b.
Pressure control knob that enables adjustment of the pressure of the air entering the
reservoir. 5-60 psi recommended for most applications.
2.
Compressed Air Line
–
The air line consists of blue polyurethane tubing designed for compressed air
use.
3.
Model 830 Valve
–
A disposable fluid path valve used to dispense material from the material
reservoir. This valve features suck-back, allowing drip-free dispensing from fill-to-fill.
4.
Disposable Fluid Path
–
The fill tube and fittings used to deliver fluid material from bulk cartridges
to syringes. It is constructed of black, light-blocking polyethylene tubing compatible with many types
of commercial and medical fluids.
5.
Material Reservoir Retainer
–
The reservoir retainers and tanks hold fluid reservoirs. Reservoir
retainers accept cartridge reservoirs. Reservoir tanks accept bottle and pail reservoirs.
6.
Material Reservoir Support
–
The adjustable vertical support is used to mount material reservoir
support.
7.
Material Reservoir Pressure Supply
–
The air supply line that pressurizes the material in the
material reservoir retainer. The air regulator controls the pressure supplied to the material reservoir.
8.
Foot Switch
–
Depression of the foot switch initiates the machine fill cycle. Once the foot switch is
depressed, the machine will automatically cycle and shut off once the fill switch is tripped.
9.
Adjustable Syringe Support
–
The support is used to ensure the syringe is supported to remain in
line with the fill stop switch and the Luer or Oral tip fitting.
10.
Fill Stop
–
The air-operated switch that controls the machine shut off once target fill volume is
achieved.
11.
Cylinder Retract Switch
–
Manual retraction switch for fill stop cylinder. This switch can be used to
stop the machine operation at any time in the cycle.
12.
Quick Clamp Release
–
The clamp mechanism is used to hold the material line in the Model 830
Valve. The clamp allows for quick and easy material line changeover.