background image

 
U S E R   G U I D E

 

|

 

B L U E W A V E   M X - 2 5 0   E M I T T E R S

 

13

 

Specifications 

Property 

Specification 

Emitter 

RediCure 

PrimeCure 

VisiCure 

Output Frequency 

365 nm 

385 nm 

405 nm 

Typical Intensity Output* 

At Array Surface 

At 25 mm 

 
680 mW/cm

255 mW/cm

2

 

 
950 mW/cm

2

 

355 mW/cm

2

 

 
1,090 mW/cm

375 mW/cm

2

 

Emitter Dimensions 
(W x D x H) 

1.97" x 1.97" x 7.6" [5 cm x 5 cm x 19.3 cm] 

Weight 

1.64 lbs. [0.74 kg] 

Unit Warranty 

1 year from purchase date 

Operating Environment 

10°C to 40°C (50°F to 104°F) 

* Measured using Dymax ACCU-CAL

 50-LED radiometer in flood mode.                                            

 

 

Figure 8.  

BlueWave

 

MX Series Spectral Output

 

 

 

RediCure

 

 

PrimeCure

 

 

VisiCure

 

 

 

Содержание BlueWave MX-250

Страница 1: ...BlueWave MX 250 LED Flood Curing Emitters User Guide ...

Страница 2: ...stems optimize the speed of automated assembly allow for 100 in line inspection and increase throughput System designs enable stand alone configuration or integration into your existing assembly line Please note that most dispensing and curing system applications are unique Dymax does not warrant the fitness of the product for the intended application Any warranty applicable to the product its app...

Страница 3: ...iew 5 Description of BlueWave MX 250 Emitters 5 Unpacking 6 Parts Included 6 Installation 6 Important Information 6 Mounting Connections 7 Troubleshooting Maintenance 9 Product Cleaning and Care 10 Glass Window Replacement 10 Compatible Devices 11 Spare Parts 11 Specifications 13 Declaration of Conformity 14 Warranty 15 Index 15 ...

Страница 4: ... email Dymax at info dymax com Contact information for additional Dymax locations can be found on the back cover of this user guide For more information about this product visit dymax com Safety WARNING If you use this UV LED light source without first reading and understanding the information in the UV Light Safety Guide SAF001 injury can result from exposure to high intensity light To reduce the...

Страница 5: ...ring system with a 50 mm x 50 mm 2 in x 2 in asserted curing area They provide manufacturers with curing flexibility and expansion capabilities The BlueWave MX 250 emitter is air cooled using an axial fan The BlueWave MX 250 emitter can be mounted using one of two hole patterns in the housing body Figure 1 Main Components of BlueWave MX 250 System Stand Power Switch Controller LED Emitter Touch Sc...

Страница 6: ... included in every package order If parts are missing from your order contact your local Dymax representative or Dymax Customer Support to resolve the problem Parts Included BlueWave MX 250 LED Emitter Assembly User Guide Installation The BlueWave MX 250 emitter is part of a MX series curing system and requires connection to a controller via an interconnect cable for proper operation Important Inf...

Страница 7: ... 0 5 mm holes Figure 2 that align with Dymax stands and holders When connecting the emitter to the controller ensure proper strain relief to prevent pinching or kinking of the interconnect cable The cooling air intake on top of unit must be free flowing do not cover Exhausting air on sides must be given at least 1 mm 0 04 of clear space to obstructions for safe use Figure 2 BlueWave MX 250 Emitter...

Страница 8: ...0 E M I T T E R S When multiple emitters are mounted side by side maintain 1 mm 0 04 of clear space between units For outermost units maintain 20 mm 0 8 of free space to obstructions for safe use Figure 3 Example of Installation Using Array Stand ...

Страница 9: ... Trigger setting on admin screen should match the desired input trigger channel LED head is not connected to the correct port channel Verify that the head is connected to the desired port channel BlueWave MX 250 LED suddenly stops producing light Over temperature shutdown was triggered Verify alarms Footswitch defective Activate unit using the front control panel Replace the footswitch if the unit...

Страница 10: ...Glass Window Replacement 1 Before starting disconnect power to the unit 2 Lay the emitter on its side with the cover facing upwards Using a 5 64 hex key loosen and fully remove the two screws Figure 4 3 Remove the side cover by lifting from the bottom as shown in Figure 5 Figure 4 Remove Screws Figure 5 Remove Side Cover 4 Slide the damaged glass cover out Figure 6 taking care not to touch the met...

Страница 11: ...T E R S 11 Figure 6 Slide Glass Cover Out Figure 7 Insert New Glass Cover 6 Reinstall the side cover removed in Step 3 7 Insert the two screws removed in Step 2 and tighten Spare Parts Item Part Number BlueWave MX 250 Emitter Glass Replacement Kit 42929 ...

Страница 12: ...385 nm 42807 BlueWave MX 250 RediCure 365 nm 42806 System Components Interconnect Cable Assembly 2 Meter 42287 Interconnect Cable Assembly 5 Meter 42889 Extended Interconnect Cable 10 Meter 43010 Extended Interconnect Cable 20 Meter 43011 Radiometer ACCU CAL 50 LED Radiometer 40505 Stands Array Stand 43070 Emitter Mounting Stand 42390 Personal Protection Equipment Three Sided Acrylic Shield 41395 ...

Страница 13: ...rray Surface At 25 mm 680 mW cm2 255 mW cm2 950 mW cm2 355 mW cm2 1 090 mW cm2 375 mW cm2 Emitter Dimensions W x D x H 1 97 x 1 97 x 7 6 5 cm x 5 cm x 19 3 cm Weight 1 64 lbs 0 74 kg Unit Warranty 1 year from purchase date Operating Environment 10 C to 40 C 50 F to 104 F Measured using Dymax ACCU CAL 50 LED radiometer in flood mode Figure 8 BlueWave MX Series Spectral Output RediCure PrimeCure Vis...

Страница 14: ...1 4 U S E R G U I D E B L U E W A V E M X 2 5 0 E M I T T E R S Declaration of Conformity ...

Страница 15: ...d by Dymax Corporation will void any effective warranties and may result in damage to the equipment IMPORTANT NOTE DYMAX CORPORATION RESERVES THE RIGHT TO INVALIDATE ANY WARRANTIES EXPRESSED OR IMPLIED DUE TO ANY REPAIRS PERFORMED OR ATTEMPTED ON DYMAX EQUIPMENT WITHOUT WRITTEN AUTHORIZATION FROM DYMAX THOSE CORRECTIVE ACTIONS LISTED ABOVE ARE LIMITED TO THIS AUTHORIZATION Index Cleaning 9 Compati...

Страница 16: ...r used under license by Dymax Corporation U S A Please note that most curing system applications are unique Dymax does not warrant the fitness of the product for the intended application Any warranty applicable to the product its application and use is strictly limited to that contained in Dymax standard Conditions of Sale published on our website Dymax recommends that any intended application be ...

Отзывы: