21
Dymax BlueWave® LED DX-1000 VisiCure® User Guide
Error Codes and Troubleshooting
If your
BlueWave LED DX-1000 VisiCure
displays an error code (
Er01
for example), you can determine the
cause of the error by referring to Table 3. If your
BlueWave
is not responding as expected, you can probably
resolve the issue using the troubleshooting chart (Table 4).
Table 3. Error Codes
Error Code
Description
Er01
Power supply failure [terminate current cure cycle and shut down]
Er02
Fan failure in Irradiator Head [Complete current cure cycle then shut down]
Er03
LED Over Temp [terminate current cure cycle and shut down]
Er04
Temp sensor open (failed or unplugged) [terminate current cure cycle and shut down]
Er05
Control box over temp [terminate current cure cycle and shut down]
Er06
LED over current [terminate current cure cycle and shut down]
Er07
If Er06 occurs and current cannot be shut down alert beeper continuous to indicate unit needs
to be powered down.
Er08
5V failure to LED. Check connections and LED module.
Fltr
Change Filter [complete current cure cycle then shut down]