background image

 

Dymax WIDECURE UV Conveyor 

SPECIFICATIONS 

 

SPECIFICATIONS 

DESCRIPTION 

18" CONVEYOR 

25" CONVEYOR 

Dymax Part Number 

39380 

39381 

UV-CURING 
INFORMATION 

Bulb Curing Width 

18" [45.7 cm] 

25" [63.5 cm] 

Peak Intensity 

900 mW/cm

2

 nominal

Energy @ 5 fpm 

4.0 J/cm

2

 nominal

Bulb Degradation 

<20% degradation over 750 hours typical 

UV Lamp Type 

400 W/in metal halide Bulb (standard

2

Reflector Type 

Focused 

BELT 
INFORMATION 

Belt Width 

25-7/8" [65.7 cm] 

32-7/8" [83.5

 

cm] 

Belt Working Height 

Adjustable from 35” to 41” [88.9 cm to 104.1 cm] above 

floor level 

Belt Material 

Teflon coated fiberglass 

Belt Speed 

Adjustable 1-50 fpm 

Speed Control 

Digital readout; 0.1 fpm increments; 2% accuracy 

Maximum Belt Load 

30 lbs [13.6 kg] 

DIMENSIONS 

Overall Dimensions  
(L x W x H) 

126" x 38" x 71" 

[320 cm x 96.5 cm x 180.3 cm] 

126" x 45" x 71" 

[320 cm x 114.3 cm x 180.3 cm]

 

In-Feed Length 

36" [91.4

 

cm] 

Shroud Length 

60" [152.4

 

cm] 

Out-Feed Length 

36" [91.4

 

cm] 

Clearance and Lamp 
Height 

Adjustable from 5" to 24" [12.7 cm to 61.0 cm] 

ELECTRICAL 
INFORMATION 

UV Lamp Electrical 
Requirements 

220 VAC

3

, 60 Hz, 50 Amps 

220 VAC

3

, 60 Hz, 80 Amps 

Single phase plus ground 

Conveyor Electrical 
Requirements 

110 VAC, 60 Hz, 15 Amps 

AIR FLOW 
INFORMATION 

Cooling Air Flow 

600 CFM 

900 CFM 

Blower Duct 
Dimensions 

8" [20.3 cm] square 

Replacement Bulbs 

39376 

– 18" Metal Halide (standard) 

39613 

– 18" Mercury 

39373

– 25" Metal Halide (standard) 

39614 

– 25" Mercury 

Shipping Weight 

650 pounds 

Lead Time 

3-7 weeks, depending upon inventory 

¹ Measured with an EIT Power Puck (320-395 nm) radiometer at a lamp height of 5" 
² Can also be outfitted with mercury bulbs (aka shortwave, UVB, UVC, "H" type) for UV inks and cationics 
³ Other UV lamp voltages are available upon request (208V, 420V, 460V)

 

 
 

Содержание 39380

Страница 1: ...WIDECURE Conveyor 18 PN39380 25 PN39381 DYMAX WIDECURE UV Light Curing Conveyors 18 and 25 Operation Manual Discontinued System ...

Страница 2: ...S Unpacking and Inspection 3 Safety 4 General Description 6 Specifications 7 Installation and System Interconnect 8 Operation 10 System Adjustments 11 Maintenance 12 Troubleshooting 13 Spare Replacement Parts 13 Definition of Terms 14 Warranty 15 ...

Страница 3: ...related to conveyor performance replacement parts troubleshooting or repair should be directed to Systematic Automation at 860 677 6400 ext 117 UNPACKING AND INSPECTION Upon receipt of the unit carefully remove the conveyor from the shipping crate and check for damage Dymax is not responsible for damage from shipping all claims for shipping damage should be made with the carrier If you observe or ...

Страница 4: ...related to UV light curing systems UV exposure high temperature surfaces ozone and bright visible light UV EXPOSURE Standard Dymax UV light curing systems and bulbs have been designed to primarily emit UVA light as shown in Chart 1 UVA light is generally considered the safest of the three UV ranges UVA UVB and UVC Although OSHA does not currently regulate ultraviolet light exposure in the workplac...

Страница 5: ...ed to quickly create workstation shielding This UV blocking flexible urethane film is available from Dymax HIGH TEMPERATURE SURFACES Surfaces exposed to high intensity curing lights will rise in temperature The intensity distance exposure time cooling fans and the type color of the surface can all affect the actual surface temperature In some cases exposed surfaces can reach temperatures capable o...

Страница 6: ... System has an External Exhaust Duct that can be attached to standard exhaust ducting External exhaust installation is recommended because the unit produces a small amount of ozone that might be a problem when exhausted to a confined or poorly ventilated space A UV Blower is provided to remove heat and ozone produced by the UV Bulb Ducting for the UV Blower exhaust is provided to the top of the cu...

Страница 7: ...26 x 38 x 71 320 cm x 96 5 cm x 180 3 cm 126 x 45 x 71 320 cm x 114 3 cm x 180 3 cm In Feed Length 36 91 4 cm Shroud Length 60 152 4 cm Out Feed Length 36 91 4 cm Clearance and Lamp Height Adjustable from 5 to 24 12 7 cm to 61 0 cm ELECTRICAL INFORMATION UV Lamp Electrical Requirements 220 VAC3 60 Hz 50 Amps 220 VAC3 60 Hz 80 Amps Single phase plus ground Conveyor Electrical Requirements 110 VAC 6...

Страница 8: ...l the four threaded Legs into the Conveyor Feet Adjust the threaded Legs as required to level the unit and to set the conveyor Belt working height 2 Provide two sources of AC power to the conveyor See Table 2 for requirements NOTE On the higher voltage models the power sources must be hard wired into the back of the conveyor by a qualified electrician The 115V model has a standard North American w...

Страница 9: ...e conveyor Belt Figure 6 Hand Crank System Figure 7 Irradiator Figure 8 Scale 7 The Curing Chamber is surrounded by an enclosure but is open on top There are panels that are screwed onto the Chamber Housing at the entry and at the exit These panels may be removed to allow for taller products to pass thru the Curing Chamber Remove only enough panels to allow your package to enter the Curing Chamber...

Страница 10: ...00W on the Touch Screen Interface to start the UV Lamp Figure 15 LAMP WARMING will appear at the bottom of the Touch Screen Once the UV Lamp is ready LAMP ON 400W will be displayed NOTE The UV Lamp must always be started at 400 W After the UV Lamp has warmed up a lower power may be selected if desired 7 Adjust the height of the UV Lamp as desired by turning the UV Irradiator s Hand Crank Figure 16...

Страница 11: ... the Belt remains relatively centered between the two Rubber Roller Guides If the Belt requires an adjustment loosen the Jam Nut and Set Screw and turn the Adjustment Screw clockwise to increase Belt tension Make this adjustment equally on both sides of the conveyor to ensure proper Belt tracking Retighten the Jam Nuts and locking Set Screws Do not over tension the Belt Over tensioning can cause t...

Страница 12: ... the lamp should now be free on both ends Remove the stainless steel button head screw Figure 3 on one side It does not matter which side you removed Figure 19 UV Lamp Housing Figure 20 Remove Top Nuts on Ceramic Pieces Figure 21 Remove One Stainless Steel Button Head Screw 7 If the irradiator is at an angle be mindful of gravity After the button head screw is removed the lamp can fall depending o...

Страница 13: ...wer Switch lights and Motor turns but Belt does not move Verify the operation of the Drive Shaft and Drive Rollers Use the tracking adjustment screws to increase the tension on the Belt Both knobs need to be turned the same amount to maintain alignment Belt Tracks to One Side Belt Adjustment Screws are out of position Visually inspect the Belt The Belt will track to one side Tighten the Belt Adjus...

Страница 14: ...are very minute amounts below 220 nm and practically nothing can be sensed below 200 nm This is due to the use of ozone blocking quartz bulb envelope See Ozone 1 Ultraviolet A UV A UV of long wavelength from approximately 400 to 320 nm of the spectral band This is the predominant energy produced by Dymax flood lamps 2 Ultraviolet B UV B UV of medium wavelength from approximately 320 to 280nm Dymax...

Страница 15: ...TIVE ACTIONS LISTED BELOW ARE LIMITED TO THIS AUTHORIZATION Dymax offers a one year warranty against defects in material and workmanship on all system components excluding bulbs with proof of purchase date Unauthorized repair modification or improper use of equipment may void warranty The use of aftermarket replacement parts not supplied or approved by Dymax Corporation will void any effective war...

Страница 16: ...r performance testing and evaluation by offering equipment trial rental and leasing programs to assist in such testing and evaluations MAN018 01 21 2015 Dymax Corporation 1 860 482 1010 info dymax com www dymax com Dymax Oligomers Coatings 1 860 626 7006 info_oc dymax com www dymax oc com Dymax Asia H K Limited 852 2460 7038 dymaxasia dymax com www dymax com cn Dymax Europe GmbH 49 611 962 7900 in...

Отзывы: