DYI SHENG DS10-P-02 Скачать руководство пользователя страница 12

INSTALLATION CONSIDERATIONS

11

Installation and Assembly Considerations
◆ 

Connect the suction and discharge ports of the pump with a hose or flexible pipe to avoid damage caused by vibration of the pump. Never step on

            the diaphragm pump or use other methods to apply weight to the pump body, or suspend the pump. Otherwise, there is a danger of personal injury 
            or equipment failure.
◆ 

The suction head of the inlet should be less than six meters (For water). 

◆ 

The direction of the pipe (inlet and outlet) can be turned, but please pay attention to the O-ring when disassembling and installing it and locking 

            the pipe well to prevent leakage.
◆ 

We suggest that you can install the air filter, regulator, and lubricator (FRL) on the air inlet of the pump.

Adjustments for connection of high air pressure
◆ 

The air source of the air compressor is connected to the air inlet of the pump through the air pressure hose. It is operated by the air filters. The

            supply air pressure used shall not exceed the maximum operating pressure.
◆ 

We suggest that you can install the air regulator on the air inlet of the pump. The supply air pressure used shall not exceed the maximum operating 

            pressure.
◆ 

Check the air filter at the air pressure input regularly to drain the accumulated wastewater and impurities. If too much wastewater is introduced

            into the pump body, the wastewater and lubricating oil will emulsify and affect the lubrication of the parts, or block the pores, thereby affecting 
            the operation performance of the pump or causing malfunction.
Air Line Moisture
◆ 

Water in the compressed air supply can create problems such as icing or freezing of the exhaust air, 

           causing the pump to cycle erratically or stop operating. Water in the air supply can be reduced by using 
           a point-of-use air dryer to supplement the user’s air-drying equipment. This device removes water from
           the compressed air supply and alleviates the icing or freezing problems.
Air cycle
◆ 

To start the pump, the air compressor provides air pressure to the body of the cylinder base of the pump,

           flowing into the Sequential and Air Valve through the air hole. It drives the diaphragm and shaft doing power conversion. 
           During the conversion process, the deflated gas is discharged through the silencer. Please make sure that the exhaust gas 
           pipeline is smooth to avoid the blockage of the pump.
Liquid delivery process
◆ 

When the pump is used for materials that tend to settle out or solidify when not in motion, the pump should be flushed

            after each use to prevent damage. (Product remaining in the pump between uses could dry out or settle out. This could 
            cause problems with the diaphragms and check valves at the restart.) In freezing temperatures, the pump must be 
            completely drained between uses in all cases.

Содержание DS10-P-02

Страница 1: ...DS10 P 02 OPERATING MANUAL ...

Страница 2: ... and Liquids Serviceability Specification 3 Material and Temperature Range 4 Exploded View Drawing 5 Screws Torque Guide 7 Dimensions 8 Important Safety Information 10 Installation Considerations 11 Installation Instructions 12 FAQ 13 Warranty Instructions 14 ...

Страница 3: ...ion below Note PPG Polypropylene add Bolivian filament ent Current specificalion Size Wetted Body Center Body Pupe Type Diaphragm Ball cover Ball Ball seat Edition 10 1 P PPG A Aluminum F Center Flange U UPE P PP S S S 316 P PP 02 L Flank Flange T PTFE TFM E PE T PTFE E PE O Santoprene ...

Страница 4: ...nyl Chloride Ammonia Asphalt Sulfuric Acid Chromic Acid Electroplate Solu on High Temperature Sauce Chili Sauce Coal Oil Vola le Oil Carrier Oil Immiscible Fluids Freezing Mixture Degreasing Agent Methylene Chloride Jam Juice Ace c Acid Leavan Slops Balsam Olive Oil Defoamer DSXX SAX OXSO X Glaze Po ery Clay Thick Liquid Bolivian Filament Note Depending on the density temperature concentration and...

Страница 5: ... thermoplas c vulcanizates TPVs are high performance elastomers which offer manufacturing flexibility ease of processing and durability It combines the characteris cs of vulcanized rubber with the processing proper es of thermoplas cs 40 135゚C Polyethylene PE The thermoplas c resin is made by polymeriza on of ethylene which is also includes a polymer of ethylene and a small amount of the polyethylen...

Страница 6: ...15 16 17 13 22 53 54 32 35 38 36 37 56 41 43 45 55 40 42 11 1 5kg cm 2 JIS B 2211 1977 G45 59 57 60 SPARE SEAL Consumptive Parts Possible 2016 01 DS10 PAFXXTX 02 1 2 2 2 4 2 2 2 2 2 2 4 2 11 2 2 2 2 2 2 17 2 2 19 2 2 2 1 1 1 1 1 1 1 1 4 1 1 1 1 1 2 1 1 41 1 1 2 44 1 45 4 2 47 49 1 51 2 52 4 1 1 2 1 1 2 4 ...

Страница 7: ...hragm 2 PD000085 SingleDiaphragm 2 PD000086 17 PadOfDiaphragm 2 PA000225 18 Oring 2 PD000010 19 ShaftCover 2 PB000176 20 Oring 2 PD000009 21 Oring 2 PD000007 22 ShaftOfDiaphragm 1 PA000084 23 BodyOfThimbleValve 1 PA000189 24 Oring 1 PD000017 25 Oring 1 PD000006 26 Oring 1 PD000004 27 Oring 3 PB000088 28 Oring 3 PD000025 29 Oring 1 PD000002 30 Thimble 1 PA000201 31 ThimbleCap 1 PB000361 32 HexagonS...

Страница 8: ...000 0 01 0 868 0 072 1 kgf m 9 8066 981 100000 100 86 8 7 233 1 lbf in 0 113 11 3 1150 1 152 0 0115 0 083 1 lbf 1 355 136 13800 13 83 0 138 12 Unit Imperial Unit Tension to Torque Conversion SI Gravity Unit Posi on Name Torque Values kgf cm 52 3 4 Hexagon Bung 165 180 Max 45 M6 Hexagon Screw 18 5 20 Max 14 M10 Steel Hexagon Screw 165 175 Max 3 M8 Hexagon Screw 85 100 Max 1 2 M8 Hexagon Screw 100 1...

Страница 9: ...8 DIMENSIONS 170 228 254 364 50 Fluid Outlet 1 Fluid Inlet 1 105 149 296 204 Air Inlet 3 8 ...

Страница 10: ...9 DIMENSIONS 311 218 168 Fliud Outlet 1 ANSI 150R F 110m m Fliud Inlet 1 ANSI 150R F 110m m 307 20 50 419 367 50 177 50 133 50 204 AIR INLET 3 8 ...

Страница 11: ...10 IMPORTANT SAFETY INFORMATION ...

Страница 12: ...ies If too much wastewater is introduced into the pump body the wastewater and lubricating oil will emulsify and affect the lubrication of the parts or block the pores thereby affecting the operation performance of the pump or causing malfunction Air Line Moisture Water in the compressed air supply can create problems such as icing or freezing of the exhaust air causing the pump to cycle erratical...

Страница 13: ...le connection Pipe Connection Style Optional Pipe Connection Style Optional Flexible connection Gauge Gauge Shut Off Valve Shut Off Valve Drain Port Drain Port Discharge Suction Air inlet Air shut Off Valve Modular Type F R L Unit INSTALLATION INSTRUCTIONS ...

Страница 14: ...mp whether lubricates sufficient or not Please clean up the dirty parts and relubrication It is recommended to add lubricating oil to the air pressure inlet pipeline every half year don t exceed 10ml each time c Sequential valve abnormal If the deterioration of the sequential if it is worn please change it d Compressed Air Lines Freezing The Slithery Mass Valve 53 might be frozen because of low te...

Страница 15: ...of the original quality of the product we will change a new one for you Improper use e g Falling Attacked Liquid input etc or abnormal operating conditions e g Flood Fire Earthquake Lightning strike Typhoon etc these damages are not covered by the warranty Improper installation self modifying wear and tear caused by not transporting in accordance with machine regulations Accident or defect caused ...

Отзывы: