2. TROUBLESHOOTING MATRIX
Condition
Reason
Solve
When turn on power, ON/OFF switch
isn’t bright.
1. Power cord don’t plug into outlet in right
position.
2. Power cord don’t plug into unit.
3. The voltage of outlet is too lower.
4. Plug or connector of power cord is imperfection.
5. Connector of power cord was broken.
6. Connecting cable came away.
7. Breaker tripped.
8. Breaker was broken.
9. ON/OFF switch was broken.
1.Plug the power cord into outlet.
2.Plug the power cord into unit.
3.Check the voltage of outlet.
4.Replace power cord.
5.Replace power cord.
6.Check the wire if came away, connect
it again.
7.Press the small red button to come
back original status.
8.Replace breaker.
9. Replace A.C switch.
After turning on power, treadmill has
sound of blowing.
1. Power cord plug in wrong position, varistor was
broken on controller.
1.Check the voltage of power is 120V.
2.Replace the controller.
When insert safe key, no display on
monitor.
1. Haven’t switch ON/OFF switch.
2. Insert the Safe key on wrong position.
3. Computer cable of 12PIN was broken.
4. Fuse of controller was broken.
5. Varistor of controller was broken.
1. Switch the A.C switch.
2. Insert the safe key on right position.
3. Replace computer cable of 12PIN.
4. Replace fuse or controller.
5. Replace varistor or controller.