DXV Wyatt VorMax Right Height Elongated D2220AA122 Скачать руководство пользователя страница 2

- 2 -

2

3

BACK-TO-BACK INSTALLATION

7302352-100 (12/17)

1

REMOVE OLD TOILET

a.  Close toilet supply valve and flush tank completely. Towel or sponge remaining water from tank and bowl.
b.  Disconnect and remove supply line. 

NOTE:

 If replacing valve, first shut off main water supply!

c.  Remove old mounting hardware, remove toilet and plug floor waste opening to prevent escaping sewer gases.
d.  Remove closet bolts from flange and clean away old wax, putty, etc. from base area.
   

  NOTE:

 Mounting surface must be clean and level 

before

 new toilet is installed!

Depending upon your plumbing and venting conditions, the flow from the 
toilet in a back-to-back installation may create a vacuum on the system and 
draw water from the opposing bowl. The National Standards Plumbing Code 
prohibits the use of a cross fitting for drainage as throw over is possible. The 
code does approve a directional "Y" style fitting with proper venting to direct 
the water downward and away from the other toilet.

Press firmly.

Wax Ring

RECOMMENDED TOOLS AND MATERIALS

Most of the procedures require the use of common tools and materials, which are available from hardware and plumbing, 
supply stores. It is essential that the tools and materials be on hand before work is begun.

Adjustable Wrench

Gasket

Wax Ring

Regular Screwdriver

10'

Level

Flexible Supply Tube

Closet Bolts

Putty Knife

Tape Measure

Hacksaw

Sealant

Recommended fitting type for  

back-to-back installations.

Содержание Wyatt VorMax Right Height Elongated D2220AA122

Страница 1: ... Right Height Elongated HET Combo Right Hand Trip Lever D23363A104 DXV VorMax Right Height Elongated Bowl D24370A121 DXV VorMax Tank Left Hand Trip Lever D24370A122 DXV VorMax Tank Right Hand Trip Lever Wyatt VorMax Right Height Elongated 2 Piece Toilet 1 28 gpf 4 8 Lpf In the United States DXV One Centennial Avenue Piscataway New Jersey 08855 Attention Director of Customer Care For residents of t...

Страница 2: ...ilet in a back to back installation may create a vacuum on the system and draw water from the opposing bowl The National Standards Plumbing Code prohibits the use of a cross fitting for drainage as throw over is possible The code does approve a directional Y style fitting with proper venting to direct the water downward and away from the other toilet Press firmly Wax Ring RECOMMENDED TOOLS AND MAT...

Страница 3: ...e bolts adequately WARNING Overtightening of water supply line nuts could result in breakage and potential flooding If the connection leaks after hand tightening replace the supply line Do not use any type of sealant on the water supply connection Use of plumber s putty pipe dope or any other type of sealant will void the warranty WARNING Do not use plumber s putty pipe dope or any other sealant o...

Страница 4: ... achieve optimal performance PROPER FLUSHING METHOD Be sure to fully depress the trip lever on each flush Do not hold the trip lever down for extended periods of time as this could allow air to enter the system which will slightly degrade performance for a few flushes Depress trip lever handle all the way A Adjust screw on the teeter bar B so rear frame C touches the frame stop D Return trip lever...

Страница 5: ...l by flushing 5 times in a row allowing the tank to refill each time to achieve optimal performance h Adjust settings according to adjustable screw setup in Step 10 i Reseat tank by shutting off water supply disconnect supply line remove tank mounting nuts inspect all gaskets and reassemble j Adjust trip lever nut by loosening the nut a quarter turn at a time clockwise reverse thread k Do not depr...

Отзывы: