- 3 -
M965495 Rev. 1.9 (5/17)
3
4
4a
MAKE WATER SUPPLY CONNECTIONS
TEST INSTALLED FAUCET
• Connect HOT water supply to LEFT INLET UNION
(1)
and COLD water supply to RIGHT INLET UNION
(2)
.
Pipe connections are 3/4
"
(19 mm) NPT. Use sealant
or Teflon tape on pipe connections.
Do not solder directly to valve body.
• With HANDLES in OFF position, turn
on WATER SUPPLIES and check all
connections for leaks.
• Operate both HANDLES to flush water
lines thoroughly.
• Lift HAND SHOWER from HOLDER, direct
spray into tub. Lift TRANSFER KNOB to
check HAND SHOWER and HOSES for leaks.
• Turn handles “off” and replace HAND SHOWER.
INSTALL VALVE BODIES and HANDLES
1-3/4''
(44 mm) MAX.
STOP RING
GROOVE
1
2
16
HOT
COLD
15
17
5
16
3
4
7
8
12
14
13
6
11
9
10
HOT
• Unpack valve assembly and remove HANDLE
(10)
by unthreading
SET SCREW
(12)
. Unthread ROSETTE
(9)
and FLANGE
(8)
removing them from VALVE BODY
(2)
.
• Thread LOCKNUT
(1)
to bottom of VALVE BODY
(2)
. Make sure
SPACER
(3)
, BRASS WASHER
(4)
and RUBBER WASHER
(5)
are installed.
• Insert VALVE BODY
(2)
through mounting hole from underside
of tub deck or mounting surface.
Note: VALVE BODY marked Hot is installed in the left Mtg. hole,
VALVE BODY marked Cold in the right when facing front of fitting.
Maximum mounting surface thickness is 1-3/4".
• Install STOP RING
(6)
onto VALVE BODY
(2)
if not in place. Install
O-RING
(7)
into groove in FLANGE
(8)
.
• Thread FLANGE
(8)
flush against STOP RING
(6)
. Thread
ROSETTE
(9)
onto VALVE BODY
(2)
until tight against it’s
internal stop.
• Align VALVE BODY
(2)
and from below tighten LOCKNUT
(1)
to secure VALVE BODY
(2)
.
INSTALL HANDLES
• Turn VALVES to off position. Align HANDLES
(10)
as shown or
as desired and install onto HANDLE ADAPTER
(11)
.
Tighten
SET SCREW
(12)
with HEX WRENCH
(13)
supplied. Push
PLUG BUTTON
(14)
into place.
HOSE CONNECTIONS
• Insert RUBBER WASHERS
(15)
into COUPLING NUTS
(16)
of
SUPPLY HOSES (
17)
and tighten making water tight connection.
Important: Loop SUPPLY HOSES (17) as illustrated so they do not kink.
3/4" X 3/4" (19 x 19 mm) NPT UNION
(NOT SUPPLIED)
HOT
3/4"
(19 mm) NPT
3/4"
(19 mm) NPT
HAND SHOWER
2
1
TRANSFER KNOB
IMPORTANT: It is strongly
recommended that
access be provided for
all enclosed
mechanical parts