background image

- 3 -

M965701 Rev. 1.1 (5/17)

3

4

INSTALL HANDLES

• Turn VALVE STEMS

 (15)

 to off position.

•  Align LEVER HANDLES

 (16) 

as shown and install onto ADAPTER

S (10)

.Tighten SET SCREW

 (17) 

with 

HEX WRENCH 

(14)

 supplied. Install PLUG BUTTONS 

(18)

.

INSTALL WALL SPOUT

•  Twist and pull off PLASTER GUARDS

 (1)

. Thread counter clock-wise ROUGH-IN NIPPLE

 (2) 

with a flat blade screwdriver 

  and remove.

• Inspect that SPOUT NIPPLE O-RINGS 

(3 & 4) 

are seated in the grooves of SPOUT NIPPLE

 (5)

. See View “A”.

• Thread SPOUT NIPPLE 

(5)

 into VALVE BODY

 (6) 

and tighten until O-RING

 (3) 

is fully seated against VALVE BODY

 (6)

.

•  Mount WALL ESCUTCHEON

 (9)

. Thread ADAPTERS 

(10)

 onto VALVE

 (11)

 until WALL ESCUTCHEON

 (9)

 is flush 

against finished wall. 

•  Inspect that ADAPTER O-RINGS 

(3, 4) 

are seated in the grooves of ADAPTER 

(5)

. See View “A”. Install ADAPTER 

(5)

 

into spout outlet and tighten with wrench. Thread SPOUT ADAPTER

 (7) 

onto ADAPTER

 (5)

 so that the groove 

extends 9/16" beyond face of ESCUTCHEON. See View “B”.

•  Push SPOUT

 (12)

 onto SPOUT ADAPTER

 (7) 

until flush against WALL ESCUTCHEON

 (9).

 If SPOUT is not against  

WALL ESCUTCHEON

 (9)

 pull spout off and adjust SPOUT ADAPTER 

(10)

.

• Tighten SET SCREW

 (13) 

with HEX WRENCH

 (14) 

supplied.

13 

17 

14

2

1

1

View A

View B

VIEW "A"

VIEW "B"

VALVE STEM

OFF

OFF

VALVE

STEM

5

6

7

11

9

11

10

12

10

16

16

SPOUT

O-RING

 

18

15

15

14

9/16"

(14mm)

GROOVE

FINISHED

WALL

GROOVE

ESCUTCHEON

Содержание Rem D3510045C

Страница 1: ...NG IN DIMENSIONS For reference 2 D 51 mm 1 5 8 41 mm 1 2 13 mm 1 1 2 37 mm 2 3 4 70 mm 8 203 mm 11 279 mm 1 7 8 48 mm 1 2 NPT UNION INLETS 1 5 8 2 1 2 41 to 62 mm FINISHED WALL FINISHED WALL 8 203 mm 4 102 mm 8 1 2 215 mm In the United States DXV One Centennial Avenue Piscataway New Jersey 08855 Attention Director of Customer Care For residents of the United States warranty information may also be...

Страница 2: ...eck for leaks Remove PLASTER GUARDS 6 and open both valves and check for leaks Close both valves and turn off water supplies Replace PLASTER GUARDS 6 and finish wall construction Determine where the finished wall location will be This measurement is very important Note The rough in measurement from the finished wall is 1 9 16 40 mm minimum and 2 7 16 62 mm maximum This is a 7 8 22 mm tolerance See...

Страница 3: ...ount WALL ESCUTCHEON 9 Thread ADAPTERS 10 onto VALVE 11 until WALL ESCUTCHEON 9 is flush against finished wall Inspect that ADAPTER O RINGS 3 4 are seated in the grooves of ADAPTER 5 See View A Install ADAPTER 5 into spout outlet and tighten with wrench Thread SPOUT ADAPTER 7 onto ADAPTER 5 so that the groove extends 9 16 beyond face of ESCUTCHEON See View B Push SPOUT 12 onto SPOUT ADAPTER 7 unti...

Страница 4: ...ve AERATOR 2 First loosen aerator set screw with HEX WRENCH 3 supplied Pull out AERATOR 2 with AERATOR KEY 4 Operate HANDLES 1 to flush water lines thoroughly Replace AERATOR 2 and tighten set screw TEST INSTALLED FAUCET OFF ON OFF ON HEX WRENCH Supplied 3 2 4 1 H960740 191 EXTENSION KIT H960838 XXX CONTROL HANDLE H960854 191 ADAPTER RECEIVER 1 2 GPM H960853 191 ADAPTER H960836 191 EXTENSION M9645...

Отзывы: