M965701 Rev. 1.1 (5/17)

1

2

INSTALL VALVE BODY

•  Mount VALVE BODY

 (1) 

to WALL BRACKET 

(2)

 as shown. Level and tighten SET SCREWS 

(3) 

to secure 

VALVE BODY

 (1)

 to WALL BRACKET 

(2)

.

•  Connect HOT water supply to LEFT INLET UNION

 (4) 

and COLD water supply to RIGHT INLET UNION

 (5)

Pipe connections are 1/2" NPT. Use sealant or Teflon tape on pipe connections. 

Do not solder directly to valve body.

•  With valves closed open supply lines and check for leaks. Remove PLASTER GUARDS

 (6) 

and open both 

valves and check for leaks.

• Close both valves and turn off water supplies. Replace PLASTER GUARDS

 (6)

 and finish wall construction.

•  Determine where the finished wall location will be. 

This measurement is very important!

 

Note: 

The rough-in measurement  

from the finished wall is; 1-9/16" (40 mm) minimum and 2-7/16" (62 mm) maximum. This is a 7/8" (22 mm) tolerance.  
See rough-in illustration above.

• Secure WALL BRACKET

 (1) 

to cross brace of wall structure at required height using six wood screws.

INSTALL WALL BRACKET

WOOD SCREWS

CROSS BRACE

WALL STUDS

16" (406 mm)

HOT

COLD

Содержание Rem D3510045C

Страница 1: ...NG IN DIMENSIONS For reference 2 D 51 mm 1 5 8 41 mm 1 2 13 mm 1 1 2 37 mm 2 3 4 70 mm 8 203 mm 11 279 mm 1 7 8 48 mm 1 2 NPT UNION INLETS 1 5 8 2 1 2 41 to 62 mm FINISHED WALL FINISHED WALL 8 203 mm 4 102 mm 8 1 2 215 mm In the United States DXV One Centennial Avenue Piscataway New Jersey 08855 Attention Director of Customer Care For residents of the United States warranty information may also be...

Страница 2: ...eck for leaks Remove PLASTER GUARDS 6 and open both valves and check for leaks Close both valves and turn off water supplies Replace PLASTER GUARDS 6 and finish wall construction Determine where the finished wall location will be This measurement is very important Note The rough in measurement from the finished wall is 1 9 16 40 mm minimum and 2 7 16 62 mm maximum This is a 7 8 22 mm tolerance See...

Страница 3: ...ount WALL ESCUTCHEON 9 Thread ADAPTERS 10 onto VALVE 11 until WALL ESCUTCHEON 9 is flush against finished wall Inspect that ADAPTER O RINGS 3 4 are seated in the grooves of ADAPTER 5 See View A Install ADAPTER 5 into spout outlet and tighten with wrench Thread SPOUT ADAPTER 7 onto ADAPTER 5 so that the groove extends 9 16 beyond face of ESCUTCHEON See View B Push SPOUT 12 onto SPOUT ADAPTER 7 unti...

Страница 4: ...ve AERATOR 2 First loosen aerator set screw with HEX WRENCH 3 supplied Pull out AERATOR 2 with AERATOR KEY 4 Operate HANDLES 1 to flush water lines thoroughly Replace AERATOR 2 and tighten set screw TEST INSTALLED FAUCET OFF ON OFF ON HEX WRENCH Supplied 3 2 4 1 H960740 191 EXTENSION KIT H960838 XXX CONTROL HANDLE H960854 191 ADAPTER RECEIVER 1 2 GPM H960853 191 ADAPTER H960836 191 EXTENSION M9645...

Отзывы: