- 3 -
3
SERVICE
SERVICE
•
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
To clean, first turn off water supply then:
• Loosen and remove LEVER HANDLE
(1)
. Loosen
HANDLE SCREW
(2)
with 2.5 mm Hex Wrench
and then pull HANDLE BASE
(3)
off.
• Unscrew ESCUTCHEON CAP
(4)
. Unscrew
the CARTRIDGE NUT
(5)
.
• Remove CARTRIDGE
(6)
. Clean inlets of
CARTRIDGE
(6)
and MANIFOLD
(7)
.
• Reassemble CARTRIDGE
(6)
. Replace CARTRIDGE
NUT
(5)
, CAP
(4)
and HANDLE assembly, check flow.
•
If SPOUT (3) leaks at swivel point the O-RINGS (2)
need to be replaced. To remove SPOUT (3):
• Loosen the SPOUT SET SCREW
(1)
with
a 3mm Hex wrench.
• Rotate the SPOUT
(3)
side to side while pulling
upward to remove SPOUT
(3)
from faucet body.
• Replace the defective parts, grease O-RINGS
then push SPOUT
(3)
back into position.
Tighten SET SCREW
(1)
.
• Check that SPOUT
(3)
rotates freely and
does not leak at the swivel point.
5
4
M965558 Rev. 1.4 (4/17)
2
3
1
4
5
6
7
CLEAN
3
1
REMOVE
INSTALL
3mm HEX
WRENCH
2