31
DX Engineering 400MAX 50 ohm Coaxial Cable
DXE-400MAX
DXE-400MAX - Bulk Cable - No Connectors - Sold by the foot
DXE-400MAX Low-Loss Cable
DXE-400MAX-500
DXE-400MAX - Bulk Cable - No Connectors - 500 foot length
DXE-400MAXDU003
DXE-400MAX Cable - PL-259 each end, Tested, 3 foot length
DXE-400MAXDU006
DXE-400MAX Cable - PL-259 each end, Tested, 6 foot length
DXE-400MAXDU009
DXE-400MAX Cable - PL-259 each end, Tested, 9 foot length
DXE-400MAXDU012
DXE-400MAX Cable - PL-259 each end, Tested, 12 foot length
DXE-400MAXDU018
DXE-400MAX Cable - PL-259 each end, Tested, 18 foot length
DXE-400MAXDU025
DXE-400MAX Cable - PL-259 each end, Tested, 25 foot length
DXE-400MAXDU050
DXE-400MAX Cable - PL-259 each end, Tested, 50 foot length
DXE-400MAXDU075
DXE-400MAX Cable - PL-259 each end, Tested, 75 foot length
DXE-400MAXDU100
DXE-400MAX Cable - PL-259 each end, Tested, 100 foot length
DXE-400MAXDU125
DXE-400MAX Cable - PL-259 each end, Tested, 125 foot length
Gas-Injected Foam Won’t Absorb Water
DXE-400MAXDU150
DXE-400MAX Cable - PL-259 each end, Tested, 150 foot length
Low-loss, gas-injected foam polyethylene
dielectric bonded tape foil covered by a
braided copper shield
.405” low-density polyethylene jacket is UV
resistant, ideal for outdoor use
Direct bury
DXE-400MAXDU175
DXE-400MAX Cable - PL-259 each end, Tested, 175 foot length
DXE-400MAXDU200
DXE-400MAX Cable - PL-259 each end, Tested, 200 foot length
DX Engineering 400MAX is premium, low-loss, 50 ohm bulk cable with a special
Type III-A, UV-resistant polyethylene jacket that is ideal for outdoor applications,
particularly direct-bury. With its larger 10 AWG stranded copper center conductor,
400MAX is specially suited for high-power amateur stations, providing a lower
loss solution for long cable runs at any power level. The high-quality construction
continues with a gas-injected foam polyethylene dielectric, followed by the highest
level of shielding from bonded aluminum tape covered by a tinned copper shield
braid. DX Engineering 400MAX Low-Loss 50 ohm Bulk Coaxial Cable uses
standard PL-259 or N connectors.
Attenuation/
100 ft.
Power
Rating
Efficiency
%
0.3 dB @ 5 MHz
6.9 kW
93 %
0.5 dB @ 10 MHz
4.8 kW
90 %
0.8 dB @ 30 MHz
2.8 kW
83 %
1.1 dB @ 50 MHz
2.1 kW
79 %
1.8 dB @ 150 MHz
1.2 kW
65 %
3.3 dB @ 450 MHz
0.7 kW
47 %
Velocity Factor: 84% (0.84)
Minimum Bend
Radius:
6” Repeated Bends
2.5” Fixed Install
DX Engineering RG-213/U 50 ohm Coaxial Cable 213U
DXE-213U
DXE-213 - Bulk Cable - No Connectors - Sold by the foot
DXE-213U MIL-Spec Cable
DXE-213U-500
DXE-213 - Bulk Cable - No Connectors - 500 foot length
DXE-213UDU003
DXE-213 Cable - PL-259 each end, Tested, 3 foot length
DXE-213UDU006
DXE-213 Cable - PL-259 each end, Tested, 6 foot length
DXE-213UDU012
DXE-213 Cable - PL-259 each end, Tested, 12 foot length
DXE-213UDU018
DXE-213 Cable - PL-259 each end, Tested, 18 foot length
DXE-213UDU025
DXE-213 Cable - PL-259 each end, Tested, 25 foot length
DXE-213UDU050
DXE-213 Cable - PL-259 each end, Tested, 50 foot length
DXE-213UDU075
DXE-213 Cable - PL-259 each end, Tested, 75 foot length
DXE-213UDU100
DXE-213 Cable - PL-259 each end, Tested, 100 foot length
Solid Polyethylene Dielectric
.405 Type II-A jacket is non-contaminating
and UV-resistant, suitable for outdoor use
Direct-bury
Braided copper shield
Direct-bury
DXE-213UDU125
DXE-213 Cable - PL-259 each end, Tested, 125 foot length
DXE-213UDU150
DXE-213 Cable - PL-259 each end, Tested, 150 foot length
DXE-213UDU175
DXE-213 Cable - PL-259 each end, Tested, 175 foot length
DXE-213UDU200
DXE-213 Cable - PL-259 each end, Tested, 200 foot length
DX Engineering RG-213/U is a low-loss, 50 ohm, MIL-spec bulk coaxial cable with
a non-contaminating Type II PVC jacket. Specially manufactured for DX
Engineering, RG-213/U cable is perfect for outdoor use due to its excellent UV
resistance and durability in direct-bury applications. Specially suited for high-
power amateur stations, RG-213/U provides a lower loss solution for long cable
runs at any power level. Featuring a solid polyethylene dielectric, DX Engineering
RG-213/U uses standard PL-259 and N connectors normally designed for RG-8
sized cables.
Attenuation/
100 ft.
Power
Rating
Efficiency
%
0.4 dB @ 5 MHz
4.9 kW
90 %
0.6 dB @ 10 MHz
3.4 kW
87 %
1.0 dB @ 30 MHz
2.0 kW
79 %
1.3 dB @ 50 MHz
1.5 kW
73 %
2.4 dB @ 150 MHz
0.9 kW
57 %
Velocity Factor: 66% (0.66)
Minimum Bend Radius: 5”