- 22 -
Position the UNUN so it faces forward. Tighten the Upper and Lower Studded Clamps and Tighten
the Nyloc Nuts on the Upper and Lower Clamps
Figure 16
.
Figure 16
Feedline Connections
The
DXE-UN-43
UNUN is attached to the feedline antenna connection using the
DXE-TCB-
UNFK
- UNUN Feed Point Connection Kit which contains two pre-drilled copper tinned braids for
connection to the vertical antenna system. Both braids are 1" wide by 9" in length. Connect one
braid from the antenna feedpoint located on the base section of the antenna to the terminal on the
DXE-UN-43
UNUN closest to the
Red "+"
on the label as shown in
Figure 17
. Do not over
tighten the wing nuts. Hand tighten them only, do not use pliers or other tools to over tighten the
wing nuts.
Connect the other 9" braid from the terminal on the
DXE-UN-43
UNUN closest to the
Black
"
▬"
on the label to the closest radial wire bolt on the optional
DXE-RADP-3
Radial Plate as
shown in
Figure 17
. Route both braided cables as shown.