- 21 -
Feedline Connections
Vertical Feedline Current Choke Connections
The optional
DXE-VFCC-H05-A
Vertical Feedline Current Choke is attached to the feedline using
the
DXE-TCB-FPK
- Feed Point Connection Kit which contains two pre-drilled copper tinned
braids for connection to the vertical antenna system. One braid is 8-1/2" long and the shorter is 7-
1/2" long. Connect the longer 8-1/2" braid from the antenna feedpoint located on the base section
of the antenna to the terminal on the
DXE-VFCC-H05-A
Vertical Feedline Current Choke closest
to the
Red
"
D
"
in "
D
X Engineering
" on the label as shown in
Figure 15
.
Connect the other 7-1/2" braid from the terminal on the
DXE-VFCC-H05-A
Vertical Feedline
Current Choke closest to the
Black "
X
"
on the label to the closest radial wire bolt on the optional
DXE-RADP-3
Radial Plate as shown in
Figures 15 and 15a
. Route both braided cables as shown.
Note:
Ensure the braided connections do not interfere with the tilting process,
and are not accidentally touching anything that could cause a short.
Figure 15
Your coaxial cable from the radio connects direct to the SO-239 connector on the
DXE-VFCC-
H05A
Vertical Feedline Current Choke.
If there is a wing nut and hardware near the SO-239, they are
spares
for the top two terminals.
DO NOT GROUND
this connection.