Warning

:

 Do not locate the antenna near overhead power lines or other electric light or power 

circuits, or where it can come into contact with such circuits.  When installing the antenna, take 
extreme care not to come into contact with such circuits, because they may cause serious injury or 
death.  
 

Manual Updates 

Every effort is made to supply the latest manual revision with each product. Occasionally a manual 
will be updated between the time your DX Engineering product is shipped and when you receive it. 
Please  check  the  DX  Engineering  web  site  (www.DXEngineering.com)  for  the  latest  revision 
manual. 

 
Features

  

 

 

Close Spacing from Transmit Antennas – Receive element is grounded at power-off  

 

Sensitive − Weak signal sensitivity rivaling full size antennas  

 

Wide Bandwidth – 100 kHz to 30 MHz  

 

Excellent Strong Signal Handling − Outstanding Third Order Intercept of +30 dBm  

 

Reduced Noise − Quiet FET followers and exceptional feedline shield isolation  

 

Long Life − High quality stainless steel and brass mounting hardware, full metal 
enclosure  

 

Compact − Stainless steel tapered element has low visual and environmental impact  

 

Easy Mounting and Installation Flexibility − Pre-drilled mounting plate and stainless 
steel U-Bolt Saddle clamps for mounting to your 4 foot ground rod 

 

May be connected to a transceiver which lacks a receive antenna input using the optional 

DXE-RTR-1A 

Receive Antenna Interface for transceivers. 

 
 
Technical Description 

 
This compact receiving antenna system is designed to operate over a very wide bandwidth from the 
broadcast band to 30 MHz with superior strong signal performance. The Third Order Intercept 
(TOI) is approxi30 dBm, reducing or eliminating spurious signals. 
 
Exceptional feedline decoupling, absent in some other popular designs, greatly reduces feedline 
conducted noise and unwanted signal interference. 
 
The 

DXE-ARAV3

 Active Receive system requires well fi10 to +15 Vdc @ 60 mA nominal 

current. This power must be supplied through the feedline using the included 

DXE-FVI-1 

Feedline 

Voltage Injector and wall mounted transformer power supply (also included).  Alternatively, well 
filtered station power may be used with a 1 amp in-line fuse. If used, the 

DXE-TVSU-1A 

Time 

Variable Sequencer Unit or 

DXE-NCC-1

 Receive Antenna Variable Phasing Controller will supply 

power for multi-element arrays. The 

DXE-TVSU-1A

 Time Variable Sequencer Unit and the 

DXE-

NCC-1

 Noise Canceling Receive Antenna Controller will interrupt the power to the

 DXE-ARAV3

 

for proper grounding during the transmit operation of the transceiver. 

Содержание ARAV3-1P

Страница 1: ...r Vertical Array Package ARAV3 8P Eight Vertical Array Package Export Models ARAV3 1PE ARAV3 2PE ARAV3 4PE ARAV3 8PE Used under US Patent No 7 423 588 DXE ARAV3 INS Revision 4a DX Engineering 2012 P O...

Страница 2: ...ription 6 Basic Tools Required 7 Installation 7 Location 7 Assembly 7 Ground Mounting Rod 9 Three Piece 102 Receiving Element WP 102E 11 Providing a Good RF Ground 12 Connections 12 Coaxial Cable Feed...

Страница 3: ...e using two ARAV3 antennas in conjunction with the DXE NCC 1 Receive Antenna Variable Phasing Controller could allow the user to phase out the noise being received Large transmit antennas are a very g...

Страница 4: ...nsmit antennas is at least 1 10 wavelength or more Ideally your receive antenna should be a minimum of 1 2 wavelength away from any transmit antenna on the lowest frequency to avoid mutual coupling an...

Страница 5: ...systems w Internal Antenna Disconnect Relays 4 Element connection wires 4 Sets of Stainless steel clamps and hardware DXE ARAV3 8P The eight active antennas system package DXE ARAV3 8P is intended fo...

Страница 6: ...ting plate and stainless steel U Bolt Saddle clamps for mounting to your 4 foot ground rod May be connected to a transceiver which lacks a receive antenna input using the optional DXE RTR 1A Receive A...

Страница 7: ...tructures becomes more pronounced At higher frequencies where the active element length becomes a partial wavelength coupling increases further Placing a DXE ARAV3 on the same mast or tower as a Yagi...

Страница 8: ...n Figure 3 Figure 3 Upper Clamp Lower Clamp NOTE The following describes the use of the DXE SSVC 1P and DXE SSVC 1PG V Clamps that are included with the ARAV3 These are used for mounting the ARAV3 on...

Страница 9: ...Drive your four foot copper clad steel ground rod into the ground far enough to provide a sturdy mount for the antenna system Ensure the ARAV3 unit will be above any potential standing water Depending...

Страница 10: ...10 Install the ground wire hardware and ground wire on the stainless steel V Clamp with the tab The other end of this wire goes to the AVA 2 ANT connection as shown in Figure 6 Figure 6...

Страница 11: ...ions together The other connector has smaller holes for joining the middle to the upper section Lower Coupler Upper Coupler Stripe Lower Section Middle Section Upper Section Figure 7 Three Section Sta...

Страница 12: ...re not recommended for transmit antennas Screen radius must at least equal the element height and be placed around the antenna as symmetrically as possible but should not exceed a radius of 20 feet Th...

Страница 13: ...ding on the number of control lines needed usually 3 or 4 you can double up the twisted pairs of CAT5e cable or use control wire that is at least 22 AWG allowing runs up to 1500 feet If you use a cabl...

Страница 14: ...r nicks displaces water and can be direct buried The feedline is used to provide power for the ARAV3 s matching unit We recommend the use of DXE SNS6 25 Snap N Seal type F connectors to ensure high qu...

Страница 15: ...ove the peak frequency does not change significantly Below the peak frequency sensitivity reduction is reasonably fast Installing a jumper in any C1 position when jumpers are being used in L1 will mov...

Страница 16: ...3 units are used in a four square array optimized for 160 meters and 80 meters with 98 feet side lengths the only jumper typically used is L1MF Configure all four ARAV3 s units in the array with the s...

Страница 17: ...1P Active Receive Vertical antenna capabilities Normally the Active Receive Vertical antenna will properly reject high angle sky wave signals which is the goal for a low band DXing receive antenna Low...

Страница 18: ...antenna feedline that is running on or above ground or similar noise as your transmit antenna for some installations the DXE RFCC 1 Receive Feedline Current Choke may help The use of the DXE RFCC 1 Re...

Страница 19: ...19 Shortwave Receiver ARAV3 1P system located greater than 1 2 wavelength from any transmitting antenna connected to a transceiver with a receive input...

Страница 20: ...preferably more than 1 2 wavelength away The NCC 1 switches the power off during transmit This configuration allows the operator to selectively null out interference and thereby enhance the desired re...

Страница 21: ...21 Typical DXE RFS SYS 4P Receive Four Square System Configuration Shown with optional items Power connections not shown for clarity Refer to the DXE RFS SYS 4P manual for details...

Страница 22: ...22 Typical DXE RCA8 SYS 4P Receive Eight Circle System Configuration Shown with optional items Power connections not shown for clarity Refer to the DXE RCA8 SYS 4P manual for details...

Страница 23: ...ity 360 brass cadmium plated with yellow chromate coating for maximum corrosion resistance UV resistant plastic and O rings provide a reliable environmentally sealed connector An installation tool suc...

Страница 24: ...dit repair or replace any item or part thereof which is proved to be other than as warranted no allowance shall be made for any labor charges of Buyer for replacement of parts adjustment or repairs or...

Отзывы: