![Dwyer Instruments ULS Series Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/dwyer-instruments/uls-series/uls-series_manual_2544534005.webp)
Rev
5
MN890570
5
of
30
SAFETY
PRECAUTIONS
Step
Four
About
this
Manual:
PLEASE
READ
THE
ENTIRE
QUICK
START
PRIOR
TO
INSTALLING
OR
USING
THIS
PRODUCT.
This
manual
includes
information
on
the
Series
ULS
Ultrasonic
Level
Switch,
controller
and
transmitter
from
Dwyer
Instruments,
Inc.
Please
refer
to
the
part
number
located
on
the
switch
label
to
verify
the
exact
model
configuration,
which
you
have
purchased.
User’s
Responsibility
for
Safety:
Dwyer
Instruments,
Inc
manufactures
a
broad
range
of
level
sensing
technologies.
While
each
of
these
sensors
is
designed
to
operate
in
a
wide
variety
of
applications,
it
is
the
user’s
responsibility
to
select
a
sensor
model
that
is
appropriate
for
the
application,
install
it
properly,
perform
tests
of
the
installed
system,
and
maintain
all
components.
The
failure
to
do
so
could
result
in
property
damage
or
serious
injury.
Proper
Installation
and
Handling:
Only
professional
staff
should
install
and/or
repair
this
product.
Install
the
transmitter
with
the
included
FKM
gasket
and
never
over
tighten
the
transmitter
within
the
fitting.
Always
check
for
leaks
prior
to
system
start
‐
up.
Wiring
and
Electrical:
A
supply
voltage
of
12
to
28
VDC
is
used
to
power
the
Series
ULS.
Electrical
wiring
of
the
transmitter
should
be
performed
in
accordance
with
all
applicable
national,
state,
and
local
codes.
Note:
Series
ULS
uses
latching
relays.
When
power
is
removed
to
the
sensor,
the
relays
will
remain
in
their
last
state.
Ex:
If
the
relay
is
energized,
when
power
is
removed,
the
relay
will
remain
in
an
energized
state.
Material
Compatibility:
The
enclosure
is
made
of
Polycarbonate
(PC).
The
transducer
is
made
of
Polyvinylidene
Fluoride
(PVDF).
Make
sure
that
the
model,
which
you
have
selected,
is
chemically
compatible
with
the
application
media.
Enclosure:
While
the
transmitter
housing
is
liquid
‐
resistant
the
Series
ULS
is
not
designed
to
be
operational
when
immersed.
It
should
be
mounted
in
such
a
way
that
the
enclosure
and
transducer
do
not
come
into
contact
with
the
application
media
under
normal
operational
conditions.
Safety
Installation
should
be
done
by
properly
trained
staff
Supply
voltage
should
never
exceed
a
maximum
of
28
VDC
Make
sure
the
sensor
is
chemically
compatible
with
your
application
Design
a
fail
‐
safe
system
that
accommodates
the
possibility
of
sensor
and/or
power
failure
This
sensor
should
not
be
used
in
classified
hazardous
environments
Make
a
Fail
‐
Safe
System:
Design
a
fail
‐
safe
system
that
accommodates
the
possibility
of
transmitter
and/or
power
failure.
Dwyer
Instruments,
Inc
recommends
the
use
of
redundant
backup
systems
and
alarms
in
addition
to
the
primary
system.
Flammable,
Explosive
or
Hazardous
Applications:
Series
ULS
should
not
be
used
within
classified
hazardous
environments.
Warning:
Always
use
the
FKM
gasket
when
installing
the
Series
ULS,
and
make
sure
that
all
electrical
wiring
of
the
switch
is
in
accordance
with
applicable
codes.