Analog Value - Set Point 2 Reset Value
This object represents the process value at which set point 2 transitions from active to
inactive. The unit of this value matches the unit of the selected process mode.
Binary Value - Set Point 2 Status
This object represents the current status of set point 2. When active, the SP2 LED on
the instrument face is illuminated.
Binary Value - Enable Alarm High Limit
This object represents the enable state of the alarm high limit. When enabled, the
alarm high limit value is compared against the current process value.
Analog Value - Alarm High Limit
This object represents the process value at which the alarm high status transitions
from inactive to active. The unit of this value matches the unit of the selected process
mode. The alarm high status transitions from active to inactive at 1% full-scale less
than this value.
Binary Value - Alarm High Limit Status
This object represents the current status of the alarm high limit. When active, the ALHI
LED on the instrument face is illuminated.
Binary Value - Enable Alarm Low Limit
This object represents the enable state of the alarm low limit. When enabled, the alarm
low limit value is compared against the current process value.
Analog Value - Alarm Low Limit
This object represents the process value at which the alarm low status transitions
from inactive to active. The unit of this value matches the unit of the selected process
mode. The alarm low status transitions from active to inactive at 1% full-scale greater
than this value.
Property
Default Value
Property Data Type
Access
Object Identifier
Object Name
Object Type
Preset Value
Status Flags
Event State
Reliability
Out Of Service
Units
Max Pres Value
Min Pres Value
AV12
“Set Point 2 Reset Value”
Analog Value
Model Specific
{0,0,0,0}
Normal
No Fault Detected
FALSE
Mode Specific
Model Specific
Model Specific
BACnet Object Identifier
Character String
BACnet Object Type
Real
BACnet Status Flags
BACnet Event State
BACnet Reliability
Boolean
BACnet Engineering Units
Real
Real
Read
Read
Read
Read/Write
Read
Read
Read
Read/Write
Read
Read
Read
Property
Default Value
Property Data Type
Access
Object Identifier
Object Name
Object Type
Preset Value
Status Flags
Event State
Reliability
Out Of Service
BV4
“Set Point 2 Status”
Binary Value
Inactive
{0,0,0,0}
Normal
No Fault Detected
FALSE
BACnet Object Identifier
Character String
BACnet Object Type
BACnet Binary PV
BACnet Status Flags
BACnet Event State
BACnet Reliability
Boolean
Read
Read
Read
Read
Read
Read
Read
Read/Write
Property
Default Value
Property Data Type
Access
Object Identifier
Object Name
Object Type
Preset Value
Status Flags
Event State
Reliability
Out Of Service
BV5
“Enable Alarm High Limit”
Binary Value
Active
{0,0,0,0}
Normal
No Fault Detected
FALSE
BACnet Object Identifier
Character String
BACnet Object Type
BACnet Binary PV
BACnet Status Flags
BACnet Event State
BACnet Reliability
Boolean
Read
Read
Read
Read/Write
Read
Read
Read
Read/Write
Property
Default Value
Property Data Type
Access
Object Identifier
Object Name
Object Type
Preset Value
Status Flags
Event State
Reliability
Out Of Service
Units
Max Pres Value
Min Pres Value
AV13
“Alarm High Limit”
Analog Value
Model Specific
{0,0,0,0}
Normal
No Fault Detected
FALSE
Mode Specific
Model Specific
Alarm Low Limit
BACnet Object Identifier
Character String
BACnet Object Type
Real
BACnet Status Flags
BACnet Event State
BACnet Reliability
Boolean
BACnet Engineering Units
Real
Real
Read
Read
Read
Read/Write
Read
Read
Read
Read/Write
Read
Read
Read
Property
Default Value
Property Data Type
Access
Object Identifier
Object Name
Object Type
Preset Value
Status Flags
Event State
Reliability
Out Of Service
BV6
“Alarm High Limit Status”
Binary Value
Inactive
{0,0,0,0}
Normal
No Fault Detected
FALSE
BACnet Object Identifier
Character String
BACnet Object Type
BACnet Binary PV
BACnet Status Flags
BACnet Event State
BACnet Reliability
Boolean
Read
Read
Read
Read/Write**
Read
Read
Read
Read/Write
**
The high alarm status can be reset to inactive by writing inactive to the present
value property. This is allowed only if the Manual Alarm Reset is Active and the
process value no longer satisfies the alarm high condition. In all other cases a
BACnet communication protocol error is returned.
Property
Default Value
Property Data Type
Access
Object Identifier
Object Name
Object Type
Preset Value
Status Flags
Event State
Reliability
Out Of Service
BV7
“Enable Alarm Low Limit”
Binary Value
Active
{0,0,0,0}
Normal
No Fault Detected
FALSE
BACnet Object Identifier
Character String
BACnet Object Type
BACnet Binary PV
BACnet Status Flags
BACnet Event State
BACnet Reliability
Boolean
Read
Read
Read
Read/Write
Read
Read
Read
Read/Write
Property
Default Value
Property Data Type
Access
Object Identifier
Object Name
Object Type
Preset Value
Status Flags
Event State
Reliability
Out Of Service
Units
Max Pres Value
Min Pres Value
AV14
“Alarm Low Limit”
Analog Value
Model Specific
{0,0,0,0}
Normal
No Fault Detected
FALSE
Mode Specific
Alarm High Limit
Model Specific
BACnet Object Identifier
Character String
BACnet Object Type
Real
BACnet Status Flags
BACnet Event State
BACnet Reliability
Boolean
BACnet Engineering Units
Real
Real
Read
Read
Read
Read/Write
Read
Read
Read
Read/Write
Read
Read
Read