background image

Pro Line 9460A User’s Manual

4-10

9. When the desired option is selected, type 

p

 and press ENTER repeatedly until you reach the 

Video Input

 menu. 

10. Select the following submenus by typing the respective menu number and pressing ENTER:

7

Rate Control Mode

The mode controlling the bit rate variation. The available modes are:

CBR —The Constant Bit Rate mode is the most effective to maintain 
the target bit rate. May drop frames rates to maintain the bit rate.

CFR —The Constant Frame Rate mode maintains the target frame 
rate. Bit rate may exceed the target value.

VBR — The Variable Bit Rate and no limitation on bit rate

Enter the new parameter value and press ENTER.

8

Intra Interval

The frequency at which a complete video frame (called I-frame) is sent 
by the encoder. Possible values are in the 1–100 range. 
Enter the new parameter value and press ENTER.

9

Intra Refresh

Enabling the refreshing of video frames to speed up recovery from 
error.

Enabled — 

type 

1

 and press ENTER

Disabled

 — type 

2

 and press ENTER

Compression Mode

Displays the compression mode used (MPEG-4)

10

Initial Streaming

Enabled — 

type 

1

 and press ENTER

Disabled

 — type 

2

 and press ENTER

11

Current Streaming State

Enabled

 — type 

1

 and press ENTER

Disabled

 — type 

2

 and press ENTER

Transport Protocol

Displays the transport protocol used (only RTP/UDP is supported)

12

Remote IP Address

The video stream destination IP

13

UDP Data Port

The video stream destination IP

14

Max Video Payload Size

Enter the new maximum payload size (ranging from 100 to 1400)

15

Using MPEG-4 H/W decoder

Enabled —

 type 

1

 and press ENTER

Disabled

 — type 

2

 and press ENTER

16

Energy vector (EV) 
transmission rate

Enabled —

 type 

1

 and press ENTER

Disabled

 — type 

2

 and press ENTER

Table 4-8: Video Input Parameters

Menu

Parameter

Description

4

Brightness

The total amount of light in a color — Possible values range from -
128-127
Enter the new parameter value and press ENTER.

Table 4-7: Encoder Parameters

Menu

Parameter

Description

Содержание Pro Line 9460A

Страница 1: ...Pro Line 9460A Vandal Resistant Mini Dome User s Manual October 13 2008...

Страница 2: ...subject to change without notice This document also contains registered trademarks and service marks that are owned by their respective companies or organizations Notice While reasonable effort was m...

Страница 3: ...Dome Camera 2 5 To install the mini dome camera 2 5 Camera Installation 2 9 Configuring the I Os 2 11 Audio 2 12 Data Transmission 2 12 Audio Input Output Types 2 12 Specifications 2 12 Alarms 2 13 U...

Страница 4: ...k Parameters 4 6 To set the Network parameters 4 6 Setting the Ethernet Communication Parameters 4 7 To set the Physical Mode parameters 4 7 Setting Advanced Parameters 4 8 To access the Advanced menu...

Страница 5: ...h the iSOC NVMS applications Furthermore it enables configuration and video viewing from web browsers and configuration via Telnet The Pro Line 9460A mini domes come pre configured with a choice of ca...

Страница 6: ...ppears within such warranty period Customer may return the defective product for replacement with the same or a later model that performs substantially the same function as the unit being replaced or...

Страница 7: ...SING OUT OF A BREACH OF THIS AGREEMENT AND OR ANY FAILURE OF THE PRODUCT S WHETHER OR NOT DVTEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN ANY EVENT DVTEL S LIABILITY SHALL NOT EXCEED THAT...

Страница 8: ...Pro Line 9460A User s Manual 1 4...

Страница 9: ...y PN DVT FDC xx Camera Housing PN DVT VDHD or DVT VDHDT Surface ring if applicable Power and alarm cables Rubber cable gland Screws packages Mounting template Installation Guides Mini Dome Install Gui...

Страница 10: ...2 2 RJ45 Connection Options Configuring the Mini Dome Camera Upon receiving Pro Line 9460A mini dome camera its basic parameters such as the IP address need to be configured To configure the device yo...

Страница 11: ...ome camera to the factory default values the IP will change back to the address created by the APIPA After discovering the mini dome camera on the IP network its network configuration parameters need...

Страница 12: ...automatically The discovered mini dome cameras appear in the Unit Management pane 7 In the Unit Management pane select the desired mini dome camera Once a mini dome camera is selected the Network con...

Страница 13: ...try point in the housing will be used to route wires and remove the appropriate conduit plug If installing in an interior location and conduit will not be used be sure to install a rubber cable gland...

Страница 14: ...gainst the mounting surface Tighten the screws sufficiently to compress the o ring moisture seals located underneath the screw heads however DO NOT OVERTIGHTEN Note For outdoor installations or wet en...

Страница 15: ...between the housing and mounting surface 5 Insert the network cable and optional power cable through one of the conduit entry points and connect them to the dome as described under bench installation...

Страница 16: ...en connecting alarms or audio snap on the EMI suppression bead provided in the accessory kit over the factory installed cable assembly to ensure emissions compliance FCC part 15 subpart B class A The...

Страница 17: ...mera Install the gimble assembly by screwing it in at the three points shown in the image below Short slit lead connector to be used when installing a WDR camera Note Bottom section of housing not sho...

Страница 18: ...is a service jack in each housing to plug a service cable to for local video adjustment and programming 3 Use the lens top lever to adjust focus and the bottom lever to adjust the field of view 4 Once...

Страница 19: ...to base Configuring the I Os The input output features on the multipole connector on the back of the device are used for alarms or events and audio control The mini dome camera has two alarm inputs an...

Страница 20: ...eiver are activated at the same time PTT will be activated and PTL will be ignored Audio Input Output Types The mini dome camera supports the following audio types The Line in audio type which require...

Страница 21: ...firmware is through an IP network connection If this update procedure fails repeat procedure Take the following facts regarding firmware update using the IP network into consideration Ensure that the...

Страница 22: ...Pro Line 9460A User s Manual 2 14...

Страница 23: ...on first access a prompt for ActiveX installation may appear to enable viewing of live video To access the Web interface via the Device Configurator 1 Open the Device Configurator by double clicking i...

Страница 24: ...P address of the device using the http IP_address format The web browser appears displaying the home page of the mini dome camera Figure 3 2 Web browser with mini dome camera home page Note You may ne...

Страница 25: ...splayed mini dome camera Web Interface Workspace The web interface consists of a navigation pane video pane and configuration pane Figure 3 3 Web Interface Workspace The following actions can be perfo...

Страница 26: ...possible to zoom in and view a selected area close up with a digital zoom To use the digital zoom 1 On the Home page or the Picture Profile web page of the web interface click the Zoom button located...

Страница 27: ...76 a 16 bc de based upon the hex to decimal conversion of the MAC address of the individual device nn nn nn na bc de To set the Network configuration parameters 1 On the Home page of the web interface...

Страница 28: ...erial port node The Serial Port page appears Figure 3 6 Serial Port page 2 On the Serial Port page of the web interface set the following parameters 3 Click Update to change the parameters or Reset to...

Страница 29: ...ofile page appears Figure 3 7 Video Profile page 3 Set the following parameters Table 3 3 Video Profile Parameters Parameter Description Video Encoder Resolution The measure of how clear and crisp the...

Страница 30: ...e versa The value range is from 2 to 31 Quant Max A parameter related to video quality A higher quantizer value means less video quality but less bit rate and vice versa The value range is from 2 to 3...

Страница 31: ...rameters Parameter Description Analog Input Brightness The total amount of light in a color Possible values range from 0 100 Contrast The range of colors in the image Possible values range from 0 100...

Страница 32: ...Pro Line 9460A User s Manual 3 10...

Страница 33: ...Configurator or directly via Telnet To access the CLI via the Device Configurator 1 Start the Device Configurator by accessing the iSOC NVSM 5 3 AdminCenter and selecting Pro Line A in the Unified Con...

Страница 34: ...on parameters of the edge device Using the CLI Using the CLI you can configure the following parameters of the displayed edge device Setting Serial Port Parameters Setting the Access Management Parame...

Страница 35: ...ameters To set Serial Port parameters 1 On the Telnet main page type 1 and press ENTER to select Serial Ports 2 Select the desired protocol To select RS232 type 1 and press ENTER To select RS422 485 t...

Страница 36: ...via the Telnet interface To set Access management parameters 1 On the Telnet main page type 2 and press ENTER to select Access Management 2 Type 1 and press ENTER to select Security 3 Type 1 and press...

Страница 37: ...ollowing System status parameters are displayed Firmware Version Mpeg 4 Version Build Date CPU Info Up time Serial Number CPU Load Boot loader version CPLD version 2 Type 2 and press ENTER to display...

Страница 38: ...twork 2 Set the following parameters by selecting the respective menu number and pressing ENTER Table 4 3 Board Temperature Parameters Menu Parameter Description 1 Critical high temperature limit Ente...

Страница 39: ...R to select Ethernet communication The NIC MAC address of the edge device is displayed 2 Type 1 and press ENTER to select 802 3 Physical Mode 3 Select the following value of the parameter by selecting...

Страница 40: ...select Video You can select one of the following submenus Video Input Video Standard or Video Input Type Once you are done setting the parameters of the selected submenu type p to return to the Video...

Страница 41: ...Description 1 Target Bit Rate The maximum number of bits per second generated by the device Valid bit rates range from 9 to 6000 kbps Enter the new target bit rate and press ENTER 2 Target Frame Rate...

Страница 42: ...the refreshing of video frames to speed up recovery from error Enabled type 1 and press ENTER Disabled type 2 and press ENTER Compression Mode Displays the compression mode used MPEG 4 10 Initial Stre...

Страница 43: ...ent Frame Rate Current Bit Rate Kb s Average Frame Rate Average Bit Rate Kb s Total Frames Total KB Total I Frame Requests Total Frames Skipped Video Input Locked 4 Type R and press ENTER to reset the...

Страница 44: ...sired option is selected type p and press ENTER repeatedly until you reach the main menu 6 Type s and press ENTER to save the changed settings To set the VSIP menu parameters 1 From the Advanced menu...

Страница 45: ...menu parameters 1 From the Advanced menu type 6 and press ENTER to select Audio You can select one of the following submenus Audio Output Audio Input Input Compression or Sample Rate Once you are done...

Страница 46: ...abled type 2 and press ENTER Packets Received Displays the number of packets received Bytes Received Displays the number of bytes received Transport Protocol Displays the transport protocol used R Res...

Страница 47: ...ameter Type 1 and press ENTER to set the parameter to ON Type 2 and press ENTER to set the parameter to OFF 3 When the desired option is selected type p and press ENTER repeatedly until you reach the...

Страница 48: ...e Advanced menu type 11 and press ENTER to select HTTP 2 The following HTTP parameters are displayed HTTP Server IP Port This parameter can be set to the desired IP port HTTP PTZ Controls This paramet...

Страница 49: ...er be Routine Low Medium High or Critical when TOS is selected or range from 0 63 when DSCP is selected Control Data Priority This parameter can either be Routine Low Medium High or Critical when TOS...

Страница 50: ...Pro Line 9460A User s Manual 4 18...

Страница 51: ...management Telnet sessions Enabled IP firmware update Enabled Network DHCP configuration Disabled IP address 176 a 16 bc de based upon the hex to decimal conversion of the MAC address of the individua...

Страница 52: ...Pro Line 9460A User s Manual A 2...

Страница 53: ...cannot get a configuration from it within one minute the device assigns itself temporary network settings based on the APIPA addressing scheme This scheme allows a device to find a unique IP address u...

Страница 54: ...Pro Line 9460A User s Manual B 2...

Страница 55: ...rable between 9 and 6000 kbps Serial Port applicable for analog cameras only Electric levels RS 232C 2 wires RS 422 485 4 wires 230 kbps max Connectors Pluggable screw terminal strip Operating mode Tr...

Страница 56: ...sed Surface 2 5 Lbs 1 2Kg 4 5 Lbs 2 0Kg Unit Shipping Weight 3 5 Lbs 1 6Kg 5 5 Lbs 2 5Kg Environment Operating Temperature 20 C to 50 C Storage Temerature 30 C to 60 C Humidity 90 non condensing Manag...

Страница 57: ...4 VIDEO AND OR ii DECODING MPEG 4 VIDEO THAT WAS ENCODED BY A CONSUMER ENGAGED IN A PERSONAL AND NONCOMMERCIAL ACTIVITY AND OR WAS OBTAINED FROM A VIDEO PROVIDER LICENSED BY MPEG LA TO PROVIDE MPEG 4...

Страница 58: ...Pro Line 9460A User s Manual D 2...

Отзывы: