DVTEL ioimage trk1 Скачать руководство пользователя страница 16

trk1 Installation Manual 

  

 8 

 

 

3.2

 

Connecting the Unit 

This section describes the procedures for connecting the unit and includes the following sub-sections: 

 

Grounding the Unit

 (page 

8

 

Connecting the Unit to the Power Supply

 (page 

8

)

 

 

Connecting the Unit to the Network

 (page 

9

 

Connecting the Video Source (Camera) to the Unit

 (page 

10

 

Connecting the Analog Video Output to an Analog Device

 (page 

10

 

Connecting the Unit to Receive Alarms from External Devices (Alarm Inputs)

 (page 

11

 

Connecting the Unit to Control an External Device (Using Relay Outputs)

 (page

 11

3.2.1

 

Grounding the Unit  

The unit must be grounded according to local regulations and codes.  

To ground the unit 

1. 

Loosen the screw of the grounding terminal located on the power connection panel of the unit. 
See 

Figure 3: trk1 Power Connection Panel

2. 

Attach a properly rated ground cable. Make sure the ring/spade terminal of the grounding 
cable is between the toothed washers. Tighten the screw. 

3. 

Ensure that the other end of the ground cable is connected to a protective earth according to 
local regulations and codes. 

3.2.2

 

Connecting the Unit to the Power Supply 

Before connecting to the power, please review the 

Electrical Safety Notice and Warnings

 (page v). 

Use a 12VDC power supply to power the unit. Following are the recommended AC adaptor specifications: 

 

Power Adaptor Input: 110-240VAC, 47-63Hz, 1A 

 

Power Adaptor Output: 12VDC, 25W, 2A 

 

Polarity:   

 

Warning:

  

To prevent bodily injury or damage to the unit, use only properly rated and approved power 
supplies and/or AC adaptors. 

To power the unit using a power outlet 

 

Warning:

  

Make sure that the power supply matches the required specifications. Electrical safety should 
always be observed. 

1. 

Connect the AC adaptor output to the terminal block on the power connection panel of the 
unit. 

2. 

Connect the AC adaptor to the power outlet. 

Содержание ioimage trk1

Страница 1: ...on Manual Ver A1 April 2013 The contents of this guide may not be reproduced or reprinted in whole or in part without the express written permission of DVTEL INC DVTEL INC 65 Challenger Road Ridgefiel...

Страница 2: ......

Страница 3: ...wer Supply 8 3 2 3 Connecting the Unit to the Network 9 3 2 4 Connecting the Video Source Camera to the Unit 10 3 2 5 Connecting the Analog Video Output to an Analog Device 10 3 2 6 Connecting the Uni...

Страница 4: ...n Panel 3 Figure 5 trk1 with Nuts Removed 6 Figure 6 Inserting Units into Rack Mount Panel 6 Figure 7 Unit Secured to Rack Mount Panel 7 Figure 8 Rack Mount Assembly with Eight Units 7 Figure 9 Config...

Страница 5: ...s document contains proprietary information belonging to DVTEL Inc This information is supplied solely for the purpose of assisting explicitly the licensee of the DVTEL units No part of this document...

Страница 6: ...rning is a precautionary message that indicates a procedure or condition where there are potential hazards of personal injury or death A Caution is a precautionary message that indicates a procedure o...

Страница 7: ...otherwise attempt to bypass the ground pin of the power cord Do not operate the unit in the absence of a suitably installed ground conductor 5 If you use an extension cord with this system make sure t...

Страница 8: ...ng overheating etc Ensure that nothing rests on the unit s cables or power cords Ample Air Circulation Leave enough space around the unit to allow free air circulation Cabling Considerations Units sho...

Страница 9: ...unit analyzes the captured video signal generates alarms and notifies operators of the presence of people vehicles or objects It can stop and detect events in multiple preset zones Users can define th...

Страница 10: ...Hardware Description This section describes the connection panels of the unit 2 2 1 Power Connection Panel The following is a description of the power connection panel of the unit Figure 3 trk1 Power...

Страница 11: ...or fence sensor etc with a dry contact output to the terminal block RELAY Relay Output Output signal opto isolated for a single external device such as an electrical door lock o NO Terminal for NORMAL...

Страница 12: ...er analysis and includes detection overlays and additional On Screen Display OSD information Typically connected to analog video equipment such as analog video displays or an analog video recording de...

Страница 13: ...ack using the rack mount panel that is available as an optional accessory When installing the unit make sure that It is securely tied down and cannot be easily dislodged Operating temperatures at all...

Страница 14: ...h rack To assemble units in a rack mount panel 1 Remove the nut and washer from each of the two video connectors on the video connection panel of the unit Figure 5 trk1 with Nuts Removed 2 Attach each...

Страница 15: ...ing the nut on the video connector Figure 7 Unit Secured to Rack Mount Panel 4 Repeat steps 1 through 3 for each of the units you want to assemble on the rack mount panel up to 8 units can be assemble...

Страница 16: ...operly rated ground cable Make sure the ring spade terminal of the grounding cable is between the toothed washers Tighten the screw 3 Ensure that the other end of the ground cable is connected to a pr...

Страница 17: ...r to the HTML Edition Units User s Guide for setting the unit IP address and required firewall settings To connect a unit to the network 1 Connect a PC laptop directly to the unit using a network cabl...

Страница 18: ...te The unit and the PC must be physically connected on the same network segment 3 2 4 Connecting the Video Source Camera to the Unit The unit accepts composite video 1Vp p from stationary analog camer...

Страница 19: ...connected to the unit s alarm input terminals An external device must fully close or fully open the circuit between the unit s alarm input terminals The unit supports a single alarm input from an exte...

Страница 20: ...FF or single pulse of predefined duration To connect a device controller to a relay output of the unit 1 Connect the leads from the external device controller to the respective terminal points on the...

Страница 21: ...the Power Supply The unit can be reset by turning off the power and then turning it on again To reset a unit by removing the power supply 1 Turn off or disconnect the power to the unit 2 Turn on or re...

Страница 22: ......

Страница 23: ...ppendix 15 Appendix This section contains the following appendices Technical Specifications page 16 Connecting Leads to a Spring Clamp Terminal Block page 18 Solo Setup page 19 Troubleshooting page 21...

Страница 24: ...75 Digital Video Outputs IP Video Streaming MPEG 4 SP MJPEG Maximum Resolution per Channel CIF Frame Rate Up to full frame rate Bit Rate CBR 128Kbps 4Mbps VBR Network Ethernet IEEE 802 3 802 3U 1 x E...

Страница 25: ...Mounting Camera Housing Shelf Optional rack mounting multiple unit accessory Environmental Specifications Operating Temperature 0 to 50 C 32 to 122 F Operating Humidity 5 to 95 non condensing Certifi...

Страница 26: ...l Block To connect a wire to the spring clamp terminal block 1 Strip the insulation from the end of each wire that is to be connected to the terminal block Approximately 1 cm 2 54 of wire should be ex...

Страница 27: ...Open the Solo Setup tab The following control icons are available on the Solo Setup keypad Icon Function Notes Start Recording Starts recording and browses to destination folder where the clip will b...

Страница 28: ...tructions how to set markers and guidelines follow instructions in the HTML Edition Units User s Guide 8 Click Browse to load the clip from the folder where it is saved 9 Use the Play Pause Fast Forwa...

Страница 29: ...nnecting the Unit to the Network The IP address responds to a ping on the network from the workstation but does not show in the Configurator Disconnect the unit s Ethernet 10 100 port or turn the powe...

Страница 30: ...ing settings Refer to the HTML Edition Units User s Guide for details Refresh your browser screen F5 Check that the bandwidth and bit rate settings of the network are set properly Check that other pro...

Страница 31: ...or activating a relay output has been defined in the unit or activate it manually Refer to the HTML Edition Units User s Guide for details Check the relay output wires are connected securely Check tha...

Страница 32: ...INDIA AND SAARC DVTEL Gesco Corporate Centre The Great Eastern Centre 70 Nehru Place New Delhi 110019 India Cel 91 129 431 5031 Fax 91 11 26209302 CALA DVTEL Mexico S A P I de C V Av Paseo de la Refo...

Отзывы: