Accessing the EN-204 via a Web Browser
83
To configure the input alarm triggered actions
From the sidebar menu, select
Configuration > Alarm Settings > Alarm Input
. The
Alarm
Input Settings
screen opens on the
Arming Schedule
tab. See Figure 79: Alarm Input
Arming Schedule (page 81).
Select the
Triggered Actions
tab. The
Alarm Input Settings > Triggered Actions
screen
opens.
Figure 80: Alarm Input Triggered Actions Screen
In the
Actions
section, select one or more of the following alarm methods:
Notify Surveillance Center
– When an event occurs, an ONVIF alarm
message is sent to the remote client PC in the Video Management
System.
Send Email
– When an event occurs, an email is sent with alarm
information to a user or users. To configure email settings, see Email
(page 63).
Upload to FTP
– Capture the image when an alarm is triggered and upload the picture to a
FTP server
.
To configure FTP settings, see
You must reboot the unit in order to activate the settings.
In the
Trigger Alarm Output
area, do one of the following when an event occurs:
Check
Select All
to trigger an external alarm output on both alarm outputs.
Check
A->1
to trigger an external alarm output on alarm output 1.
Check
A->2
to trigger an external alarm output on alarm output 2.