EN-204 User and Installation Guide
78
5.4.5
Serial Port Settings
The unit’s RS-232 serial port is used by a technician for troubleshooting. The encoder’s RS-485
serial port is used to control PTZ cameras.
To configure the RS-232 port
From the sidebar menu, select
Configuration > Serial Port Settings > 232 Serial Port
. The
232 Serial Port
screen opens:
Figure 77: RS-232 Settings Screen
Select the settings from the drop-down list. Default settings are:
Baud Rate – 115200
(Select from 300-115200)
Data Bit – 8
(Select from 5-8)
Stop Bit – 1
(Select 1 or 2)
Parity – None
(Select
None, Even,
or
Odd
)
Flow Control – None
(Select
None, Hardware,
or
Software
)
Usage – Console
(Select
Console
or
Transparent.
Use
Transparent
when you want data to flow directly to and from the camera
.
)
Click
Save
.