K100-C
Dec’15
- 15 -
Do not attempt to operate the Unit without first checking
whether there is oil in the Oil Reservoir. Add oil as required.
Serious damage may result from use, however limited, without
oil.
Initial Start-up
1) Open the RH Front Access Panel, and ensure
that there is sufficient Oil in the Oil Reservoir.
Refer to the ‘Lubrication’ section (Page 11) in this
manual for proper type and level of Oil.
2) Ensure the Shipping Cleats are removed as
indicated on Page 6.
3) Do a brief visual inspection of the Unit.
Start-up Procedures
Do not place any materials in close proximity
to the Compressor. Placing materials against
or close to the Unit will limit the cooling
required, and could lead to premature failure.
Shut off all power to the Compressor Unit
before attempting any repair or maintenance.
Adjusting the settings of the Controller could adversely affect
the performance of the Unit. Only those individuals with
knowledge of the Unit should make any adjustments.
4) Place the Fused Disconnect / Breaker in the ‘On’
Position. Check that there is power to the
Controller.
5) Turn the Unit on momentarily by pressing the
‘Start’ Button on the ‘CSC300’ Controller.
Immediately press the ‘Emergency Stop’ Button
to stop the Unit. Ensure the Motor/Air End are
rotating in the correct direction. See ‘Motor/Air
End Rotation on Page 13.
Also ensure the Cooling Fan is rotating correctly.
See Page 14.
6) Allow the Unit to operate for approximately 15
minutes. During this time, measure the amp draw
and voltage of the Unit at full load, and ensure
that these do not exceed the figures as noted on
the Unit.
7) Stop the Compressor by pressing the ‘Stop’
Button on the Units ‘CSC300’ Control Pad. Check
for any air or oil leaks.
If the rotation of the Air End is incorrect,
switch the phases ‘T1’ and ‘T3’ between the
Inverter and Motor. Refer to the
accompanying wiring schematic.
Stop Button
Use this to
shut the Unit
off. Allows the
Unit to idle
and then stop
after several
seconds.
Unit Controls
Start Button
Allows the Unit to
start.
Emergency Stop Button
Do not use to normally stop the Unit. To be used to
stop the Unit in emergencies only. Normal use will
damage electrical controls and Shaft Seal.