5
RMO200D
Introduction
Using DV Win the result can be printed like an Excel table which later can be shown as a diagram and used
for a report.
Test is completed when the test time previously set in the menu has elapsed, or when the
STOP
button is
pressed.
By pushing
STOP
button test could be performed at any time. In case of test interruption by pushing the
STOP
button, the last measured result will remain saved in the internal memory.
Upon expiry of the selected test lasting time, the last result remains saved at selected memory location.
Note 1:
Choose test current so that for the expected resistance you have maximum value of it.
Note 2:
Using DV Win enables
starting and controlling RMO200D from the PC. The results could be
stored to PC. Using DV Win after testings enables result transfer from the internal RMO200D
memory to
PC.
Note 3:
At the start of the test (Single, Continuous and CC), a check of cables connection is done. In
case of disconnection, or erroneous polarity, an alarm is activated, and the error message is
shown on the display.
Voltage sense cables disconnection, occured during the test, will cause an erroreous result.
The display will not show this as an error message.
During tests the high continued DC current will heat up the test set. To prevent RMO200D
from overheating, duty cycles apply. The duty cycles depend on the used test current, please
refer to section "Duty Cycles".