Dux Prodigy 5 135DB5N Скачать руководство пользователя страница 10

Owner’s Manual – Prodigy 5

8

H3109    3109    Rev. J

Caution:

Do not light the water heater until it has 
been filled with water (see Filling the 
Water Heater on page 7).
Do not attempt to light the water heater 
if the pilot is out and the knob is in 
the “ON” position (one of the number 
settings). Follow the steps below.

Important Safety Note:

Do not look directly into the burner area. 
Keep your head above the top of the 
access cover opening. Use a mirror to 
observe the flame.

Lighting Procedure:

The diagram on the next page shows 
the location of the control knob and the 
igniter button on the gas control valve.
1.  Remove the access cover. (A copy of 

 

the lighting procedure can also be 

 

found on the inside of the access 
cover).

2.  Turn the control knob fully clockwise to 

the “•” (off) position.

3.  Wait five (5) minutes so any build-up of 

unburnt gas can escape.

4.  Turn the control knob to the 

 (pilot) 

position.

5.  Depress the control knob fully (until 

 

disappears below housing) and after 
thirty (30) seconds, whilst keeping the 
control knob depressed, repeatedly 

press the igniter button (for up to 40 
seconds) until the pilot flame ignites.

 

Note - it is not possible to depress the 
control knob fully if the gas control valve 
has activated its safety shutoff feature. 
In this case, wait sixty (60) seconds for 
the gas control valve to reset.

6.  Keep the control knob depressed for 

twenty (20) seconds after the pilot 
flame lights. Use a mirror to observe 
the pilot flame. Do not attempt to 
observe the flame directly. 

7.  Release the control knob and check 

the pilot is still alight.

8.  If the pilot has failed to light or has not 

remained alight, turn the control knob 
to “•” (off). Wait five (5) minutes for the 
escape of unburnt gas, then begin 
again at step 4.

9.  When the pilot flame remains alight 

with the control knob released, turn 
the control knob anticlockwise to one 
of the number settings. A minimum 
setting of “6” is recommended and 
this will give a water temperature of 
about 60°C.

10.  Turn the control knob to a 

higher number for higher water 
temperatures.

11.  If the main burner does not light 

at the selected setting, the water 
may already be at the selected 
temperature.

12.  Replace the access cover and ensure 

it is firmly in position.

Lighting the Water Heater

Содержание Prodigy 5 135DB5N

Страница 1: ...s manufactured and sold after 1st July 2016 For advice repairs and service call 1300 365 115 Australia 0800 729 389 New Zealand Carefully remove all packaging and transit protection from the heater be...

Страница 2: ...s 1 Specifications 4 Plumbing Connections 5 Gas Connection and Filling 7 Lighting the Water Heater 8 Shut Down and Draining 9 Testing 10 Owner s Information 11 System Maintenance 13 Considering a Serv...

Страница 3: ...nship Pool Heating This water heater must not be used for pool heating Location The water heater must be installed outdoors The water heater should be located as close as possible to the most frequent...

Страница 4: ...height of the water heater is recommended as clearance to provide access to the anode At least 500 mm from any external corner At least 500 mm from any return wall or other structure facing the side...

Страница 5: ...fixed to the wall with suitable fasteners and fixed to the water heater with the self drilling screws provided Water Supply This water heater has been manufactured to suit the water conditions of most...

Страница 6: ...00 1400 1400 Gas Consumption MJ h 28 26 33 32 Injector Size mm 2 35 1 40 2 55 1 55 Nominal Dimensions 135L 170L A Overall Height mm 1600 1895 B Outlet Height mm 1325 1620 C Inlet Height mm 220 220 D G...

Страница 7: ...uidance on these types of installations Caution Care must be taken when attaching pipe saddles to the water heater We recommend the use of self drilling screws no longer than 12 mm Hot Water Connectio...

Страница 8: ...ee the diagram below for details Water Supply Pressure This water heater is designed for direct connection to water supply pressures of up to 1120 kPa Where the mains pressure can exceed or fluctuate...

Страница 9: ...pe before the connections are completed The grommet must then be clipped into the case A union should be used to connect the gas pipe to the RP DN15 socket on the gas control valve Ensure the union is...

Страница 10: ...depressed repeatedly press the igniter button for up to 40 seconds until the pilot flame ignites Note it is not possible to depress the control knob fully if the gas control valve has activated its s...

Страница 11: ...cover Draining the Water Heater 1 Shut down the water heater by carrying out the steps listed at left 2 Gently operate the easing lever on the Pressure Temperature Relief PTR Valve to release the pre...

Страница 12: ...knob until the main burner lights 5 With the main burner alight measure the pressure 6 Turn the thermostat knob to the off position and turn off the gas isolation valve 7 Disconnect the manometer and...

Страница 13: ...Relief PTR Valve must be installed directly into the top socket marked RELIEF VALVE The PTR Valve rating is shown on the compliance plate The valve must not be tampered with or removed The water heate...

Страница 14: ...are not expecting to need hot water for more than a few days the control knob on the gas control valve thermostat can be set to the pilot position to conserve energy Alternatively the water heater can...

Страница 15: ...heater is not recommended Annual Service This service should only be carried out by a licensed tradesperson We recommend your local Dux Service Agent The service should include the following Inspect...

Страница 16: ...ap A small leak can waste a large quantity of hot water Replace faulty tap washers and arrange for your plumber to rectify any leaking pipe work Is the Pressure Temperature Relief Valve discharging to...

Страница 17: ...Warranty Dux also warrants against failure of the flue damper for a total of five years Conditions apply see below During this period Dux will repair or replace any failed flue damper component or whe...

Страница 18: ...s more than 100km from a Dux office or Dux agent the Owner will be responsible under the warranty for paying the costs of transporting the water heater and or any component in the water heater to and...

Страница 19: ...the water heater payment of the reasonable costs of having the water heater repaired payment in respect of the reduced value of the water heater How to Make a Warranty Claim Warranty claims can be pl...

Страница 20: ...ure www dux com au warranty Please Register Your Water Heater Please take a moment to fill out your details for warranty registration at This will ensure all your current details are registered with u...

Отзывы: