MR PLUMBER.

PLEASE NOTE this Dux Endurance unit is supplied factory 
set at 50℃ outlet hot water temperature to comply with 
the requirements of AS 3498-2009. 
 

This Endurance hot water unit does not require a tempering  
valve to be installed.

Installation instructions.

Please follow all the installation instructions in the Dux Endurance Installation and  
operating instructions handbook and the following additional instructions for the  
Hot water outlet connection.  
 

1. When connecting the hot water supply to the fixtures in the property a minimum  
  of Four (4) Metres of pipework must be used between the outlet of the Dux En- 
  durance water heater and the first tap and outlet. See Diagram below 1. 

2. The Hot water line should be insulated with Ensolex or similar pipe insulation. 
 
3. When the installation is completed the temperature is to be tested at the taps to 
  confirm the water temperature does not exceed the required 50℃ setting. 
 
                                       PLEASE SEE REVERSE SIDE.

FIRST TAP OR OUTLET

TOTAL LENGTH TO FIRST TAP OR OUTLET IS  

REQUIRED TO BE A MINIMUM OF FOUR (4)  

METRES FROM THE OUTLET CONNECTION OF  

THE WATER HEATER.

*Pipe size is nominal 18 mm 
 from hot water outlet to the 
 first tap or outlet.

* 

Diagram 1.

GAS 

COLD 

HOT

Содержание Endurance six

Страница 1: ......

Страница 2: ......

Страница 3: ...The Endurance Six is pre set at 50 C maximum water temperature...

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ......

Страница 18: ...Six is pre set at 50 C maximum water temperature to comply with AS3498 2009 Consequently it does not require a tempering valve If remote controllers are installed the maximum temperature setting will...

Страница 19: ...Six is pre set at 50 C maximum water temperature to comply with AS3498 2009 Consequently it does not require a tempering valve If remote controllers are installed the maximum temperature setting will...

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ...ter outlet Valve 1 Valve 2 Outlet to deliver hot water to sanitary fixtures Hot water outlet Pipe size 20mm L COMMISSIONING THE WATER HEATER 1 After completion of the water heater installation the fol...

Страница 30: ...y to the fixtures in the property a minimum of Four 4 Metres of pipework must be used between the outlet of the Dux En durance water heater and the first tap and outlet See Diagram below 1 2 The Hot w...

Отзывы: