Relief Valve:

The Pressure & Temperature Relief (PTR) 
Valve is supplied loose with the water 
heater.

The PTR Valve rating is 1400 kPa.

The PTR Valve rating is also shown 
on the compliance plate. The PTR 
Valve must be installed directly into the 
RP½”(DN15) socket marked “RELIEF 
VALVE” at the top of the water heater on 
the right hand side.
Ensure that a sealing material is applied 
to the PTR Valve to prevent water leaks.
The drain line from this valve must be 
made of copper and run in  
accordance with the requirements of 
AS/NZS 3500.4.
The PTR Valve and its drain outlet 
pipe must not be sealed or blocked. 
A separate drain line must be run for 
the valve. It is not permitted to couple 
drain lines from relief valves into a single 
common drain line.
It is normal for the valve to leak a small 
amount of water during heating cycles.
The PTR Valve is not intended to enable 
connection of the water heater to 
supplementary energy sources such as 
solar panels or slow combustion stoves. 
Refer to AS/NZS 3500.4 for guidance 
on these types of installations.

Caution:

Care must be taken when attaching 
pipe saddles to the water heater. We 
recommend the use of self drilling 
screws no longer than 12 mm.

Hot Water Connection:

The hot water pipe is to be connected 
into the RP¾”(DN20) socket marked 
“OUTLET” at the top of the water heater 
on the left hand side.
It is recommended that all hot water 
pipes are insulated. Hot water pipes 
installed outdoors should be insulated 
with UV stabilised insulation.
Plastic pipes or fittings shall not be used 
within 1 metre of the outlet although 
they may be used downstream of a 
temperature control valve. Refer to  
AS/NZS 3500.4 for further details.

Temperature Protection:

Water heaters can produce very hot 
water. To reduce the risk of scald injury, 
it is mandatory under the requirements 
of AS/NZS 3500.4 that an approved 
temperature control device be fitted to 
the hot water supply to outlets used 
primarily for personal hygiene. This valve 
should be checked at regular intervals to 
ensure its operation and settings remain 
correct.
 

Plumbing Connections

Содержание 135ZB4N

Страница 1: ...eaters manufactured and sold after 1st July 2016 For advice repairs and service call 1300 365 115 Australia 0800 729 389 New Zealand Carefully remove all packaging and transit protection from the heat...

Страница 2: ...s 1 Specifications 4 Plumbing Connections 5 Gas Connection and Filling 7 Lighting the Water Heater 8 Shut Down and Draining 9 Testing 10 Owner s Information 11 System Maintenance 13 Considering a Serv...

Страница 3: ...anship Pool Heating This water heater must not be used for pool heating Location The water heater must be installed outdoors The water heater should be located as close as possible to the most frequen...

Страница 4: ...the height of the water heater is recommended as clearance to provide access to the anode At least 500 mm from any external corner At least 500 mm from any return wall or other structure facing the si...

Страница 5: ...fixed to the wall with suitable fasteners and fixed to the water heater with the self drilling screws provided Water Supply This water heater has been manufactured to suit the water conditions of most...

Страница 6: ...ure kPa 1400 1400 1400 1400 Gas Consumption MJ h 29 5 28 33 5 32 Injector Size mm 2 35 1 35 2 55 1 50 Nominal Dimensions 135L 170L A Overall Height mm 1600 1895 B Outlet Height mm 1325 1620 C Inlet He...

Страница 7: ...nergy sources such as solar panels or slow combustion stoves Refer to AS NZS 3500 4 for guidance on these types of installations Caution Care must be taken when attaching pipe saddles to the water hea...

Страница 8: ...or direct connection to water supply pressures of up to 1120 kPa Where the mains pressure can exceed or fluctuate beyond the pressure shown above a pressure reducing valve must be fitted in the cold w...

Страница 9: ...before the connections are completed The grommet must then be clipped into the case A union should be used to connect the gas pipe to the RP DN15 socket on the gas control valve Ensure that the union...

Страница 10: ...flame ignites Note it is not possible to depress the control knob fully if the gas control valve has activated its safety shutoff feature In this case wait sixty 60 seconds for the gas control valve t...

Страница 11: ...the access cover Draining the Water Heater 1 Shut down the water heater by carrying out the steps listed at left 2 Gently operate the easing lever on the Pressure Temperature Relief PTR Valve to relea...

Страница 12: ...the Water Heater on page 8 4 If necessary adjust the control knob until the main burner lights 5 With the main burner alight measure the pressure 6 Turn the thermostat knob to the off position and tur...

Страница 13: ...Relief PTR Valve must be installed directly into the top socket marked RELIEF VALVE The PTR Valve rating is shown on the compliance plate The valve must not be tampered with or removed The water heate...

Страница 14: ...t expecting to need hot water for more than a few days the control knob on the gas control valve thermostat can be set to the pilot position to conserve energy Alternatively the water heater can be sh...

Страница 15: ...e water heater is not recommended Annual Service This service should only be carried out by a licensed tradesperson We recommend your local Dux Service Agent The service should include the following I...

Страница 16: ...water tap A small leak can waste a large quantity of hot water Replace faulty tap washers and arrange for your plumber to rectify any leaking pipe work Is the Pressure Temperature Relief Valve dischar...

Страница 17: ...low During this period Dux will provide a replacement water heater free of charge Installation and other labour costs are the responsibility of the owner Warranty Conditions The warranty only applies...

Страница 18: ...due to defects of any kind in the water heater will only be met by Dux where the damage could be considered reasonably foreseeable and the water heater was installed in accordance with the installati...

Страница 19: ...f the water heater Provide your full name address and contact number Provide proof of date of installation for warranty to commence from that date rather than from the date of manufacture See Commence...

Страница 20: ...ill help extend its lifespan and reduce running costs Please register for preventative maintenance at www dux com au warranty Please Register Your Water Heater Please take a moment to fill out your de...

Отзывы: