Dux 135ZB4N Скачать руководство пользователя страница 10

Owner’s Manual – Prodigy 4

8

H3071    3071    Rev. K

Caution:

Do not light the water heater until it has 
been filled with water (see Filling the 
Water Heater on page 7).
Do not attempt to light the water heater 
if the pilot is out and the knob is in 
the “ON” position (one of the number 
settings). Follow the steps below.

Lighting Procedure:

The diagram on the next page shows 
the location of the control knob and the 
igniter button on the gas control valve.
1.  Remove the access cover. (A copy of  

the lighting procedure can also be  
found on the inside of the access 
cover).

2.  Turn the control knob fully clockwise to 

the “•” (off) position.

3.  Wait five (5) minutes so any build up of 

unburnt gas can escape.

4.  Turn the control knob to the 

 (pilot) 

position.

5.  Depress the control knob fully (until 

 

disappears below housing) and after 
thirty (30) seconds, whilst keeping the 
control knob depressed, repeatedly 
press the igniter button (for up to 40 
seconds) until the pilot flame ignites. 
 
Note - it is not possible to depress the 
control knob fully if the gas control valve 
has activated its safety shutoff feature. 
In this case, wait sixty (60) seconds for 
the gas control valve to reset.

6.  Keep the control knob depressed for 

twenty (20) seconds after the pilot 
flame lights. The pilot flame can be 
observed if a mirror is placed directly 
below the pilot assembly.

7.  Release the control knob and check 

that the pilot is still alight.

8.  If the pilot has failed to light or has not 

remained alight, turn the control knob 
to “•” (off). Wait five (5) minutes for the 
escape of unburnt gas, then begin 
again at step 4.

9.  When the pilot flame remains alight 

with the control knob released, turn 
the control knob anticlockwise to one 
of the number settings. A minimum 
setting of “6” is recommended and 
this will give a water temperature of 
about 60°C.

10.  Turn the control knob to a 

higher number for higher water 
temperatures.

11.  If the main burner does not light 

at the selected setting, the water 
may already be at the selected 
temperature.

12.  Replace the access cover and ensure 

that it is firmly in position.

Lighting the Water Heater

Содержание 135ZB4N

Страница 1: ...eaters manufactured and sold after 1st July 2016 For advice repairs and service call 1300 365 115 Australia 0800 729 389 New Zealand Carefully remove all packaging and transit protection from the heat...

Страница 2: ...s 1 Specifications 4 Plumbing Connections 5 Gas Connection and Filling 7 Lighting the Water Heater 8 Shut Down and Draining 9 Testing 10 Owner s Information 11 System Maintenance 13 Considering a Serv...

Страница 3: ...anship Pool Heating This water heater must not be used for pool heating Location The water heater must be installed outdoors The water heater should be located as close as possible to the most frequen...

Страница 4: ...the height of the water heater is recommended as clearance to provide access to the anode At least 500 mm from any external corner At least 500 mm from any return wall or other structure facing the si...

Страница 5: ...fixed to the wall with suitable fasteners and fixed to the water heater with the self drilling screws provided Water Supply This water heater has been manufactured to suit the water conditions of most...

Страница 6: ...ure kPa 1400 1400 1400 1400 Gas Consumption MJ h 29 5 28 33 5 32 Injector Size mm 2 35 1 35 2 55 1 50 Nominal Dimensions 135L 170L A Overall Height mm 1600 1895 B Outlet Height mm 1325 1620 C Inlet He...

Страница 7: ...nergy sources such as solar panels or slow combustion stoves Refer to AS NZS 3500 4 for guidance on these types of installations Caution Care must be taken when attaching pipe saddles to the water hea...

Страница 8: ...or direct connection to water supply pressures of up to 1120 kPa Where the mains pressure can exceed or fluctuate beyond the pressure shown above a pressure reducing valve must be fitted in the cold w...

Страница 9: ...before the connections are completed The grommet must then be clipped into the case A union should be used to connect the gas pipe to the RP DN15 socket on the gas control valve Ensure that the union...

Страница 10: ...flame ignites Note it is not possible to depress the control knob fully if the gas control valve has activated its safety shutoff feature In this case wait sixty 60 seconds for the gas control valve t...

Страница 11: ...the access cover Draining the Water Heater 1 Shut down the water heater by carrying out the steps listed at left 2 Gently operate the easing lever on the Pressure Temperature Relief PTR Valve to relea...

Страница 12: ...the Water Heater on page 8 4 If necessary adjust the control knob until the main burner lights 5 With the main burner alight measure the pressure 6 Turn the thermostat knob to the off position and tur...

Страница 13: ...Relief PTR Valve must be installed directly into the top socket marked RELIEF VALVE The PTR Valve rating is shown on the compliance plate The valve must not be tampered with or removed The water heate...

Страница 14: ...t expecting to need hot water for more than a few days the control knob on the gas control valve thermostat can be set to the pilot position to conserve energy Alternatively the water heater can be sh...

Страница 15: ...e water heater is not recommended Annual Service This service should only be carried out by a licensed tradesperson We recommend your local Dux Service Agent The service should include the following I...

Страница 16: ...water tap A small leak can waste a large quantity of hot water Replace faulty tap washers and arrange for your plumber to rectify any leaking pipe work Is the Pressure Temperature Relief Valve dischar...

Страница 17: ...low During this period Dux will provide a replacement water heater free of charge Installation and other labour costs are the responsibility of the owner Warranty Conditions The warranty only applies...

Страница 18: ...due to defects of any kind in the water heater will only be met by Dux where the damage could be considered reasonably foreseeable and the water heater was installed in accordance with the installati...

Страница 19: ...f the water heater Provide your full name address and contact number Provide proof of date of installation for warranty to commence from that date rather than from the date of manufacture See Commence...

Страница 20: ...ill help extend its lifespan and reduce running costs Please register for preventative maintenance at www dux com au warranty Please Register Your Water Heater Please take a moment to fill out your de...

Отзывы: