![Dustcontrol RAF 500S Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/dustcontrol/raf-500s/raf-500s_original-instructions-manual_2543239010.webp)
RAF 500S - 10
Part No 9070-A
Technical Data
Pressure loss
Motor kW
5.5
Pump RPM
rpm
3000
Weight kg 180
Max dp
kPa
9.5
Max Q
m
3
/h 1100
Sound Level*
)
dB(A)
without silencing enclosure
79
with silencing enclosure
66
Inlet/Outlet
mm
108/100
*
)
with exhaust silencer, 1 m
kPa Pu
10
8
6
4
2
0
1
2
3
4
5
kW P
Q
m
3
/h
RAF 500S
RAF 500
RAF 500S
200
400
600
800
1000
RAF 500
Description
Dustcontrols fans are so called radial fans. The air
is introduced into the fan at the centre of the fan
wheel and is forced outward to the fan housing
and through the outlet by the centrifugal force. The
pressure is generated in two stages.
The fans are direct driven with maintenance free
motors. Lubrication points are available on the
motor if specifi ed when ordering.
The fan is equipped with vibration isolators and
hith quality sound insulation. External inline silen-
cing on the outlet can be installed.
The fan is maintenance free unless the motor is
equipped with lubrication points. In this case the
manufacturers guidelines should be followed.