![Dustcontrol DC 2800 EX RVS Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/dustcontrol/dc-2800-ex-rvs/dc-2800-ex-rvs_original-instructions-manual_2543275011.webp)
DC 2800 EX, 11
Part No 9496
Problem Fault
Solution
Motor will not start.
Machine not connected.
Make sure connection.
Blower is blocked
Order service.
Temperature exceeds
Break the electic connection,
+ 55 degrees Celsius.
wait for approx. 30 min. Then
connect
again.
The motor stops directly
Incorrect fuse.
Change to correct fuse.
after starting.
Blower is blocked.
Order service.
Temperature exceeds
Break the electric connection,
+ 55 degrees Celsius.
wait for approx. 30 min. Then
connect
again.
Motor runs but no suction.
Hose not connected.
Connect the hose.
Hose plugged.
Find and remove block.
The container is not closed.
Close the container.
Fan runs but poor suction.
Hole in the hose.
Change or repair hose.
Plugged
fi lter.
Clean or change fi lter.
Hose too long or too small.
Change the hose.
Hose is kinked.
Check and free.
Machine top is mounted
Adjust the mounting.
incorrectly.
Dust is packed in the
Take off the top and clean
cyclone.
out.
Machine blows dust.
Filter is perforated or has
Check the fi lters and change
come loose.
if necessary.
Abnormal sound from
Something might be
Order service.
machine.
broken.
TROUBLE SHOOTING
EN
G
L
ISH
Warranty
Th
e warranty period for this machine is two years and co-
vers manufacturers faults. Th
e warranty is valid under the
condition that the machine is used under normal conditions
on the task for which it was designed and is maintained
properly.
Normal wear is not covered by this warranty. Service per-
formed by other than Dustcontrol or its autho-rized agent
voids automatically the warranty. No other warranty express
or implied is applicable.