Service
During cleaning and service of the unit, the unit should
be disconnected from the power supply.
Th
e fi ne fi lter should be changed at least once per year.
Use only original parts for replacement. If the unit is
equipped with a HEPA fi lter, this fi lter should be changed
every 300 working hours. Use breathing protection and
perform this operation in a contained area. Th
e used fi lter
should be placed in containment and disposed of in the
proper and prescribed method.
Filter change:
Remove the motor head. Lift the fi lter straight up out of
the cyclone. When required, the enclosed plastic sack can
be placed over the cyclone for a dust-free fi lter change.
Th
e fi lter is lifted directly into the sack.
During the fi lter change, check the fi lter gasket. A dama-
ged gasket can allow the release of hazardous dust. Never
use old gaskets or after-market fi lters. Use only genuine
Dustcontrol spare parts to maintain the unit for use on
hazardous dusts.
Check regularly that the electrical cable is not damaged.
Th
e DC 2800 EX should be performance tested at least
once per year because it may be used in explosive inviron-
ments. Worn parts must be replaced.
For vacuum motor the typical average > 10 000 hours.
Description Part
no
Fine fi lter, polyester with
integrated fi lter cover
42028
Microfi lter
42027
Other accessories, see Dustcontrol catalogue.
Accessories